Catalog excerpts
AUE, AUD, AUED UNI-EN 12845 fire-fighting systems
Open the catalog to page 1INDEX AUE 11 UNI-EN 12845 units with 1 N series electric main pump AUE 21 UNI-EN 12845 units with 2 N series electric main pumps AUD 11 UNI-EN 12845 units with 1 N series main pump (diesel motor) AUED 21 UNI-EN 12845 units with 2 N series main pumps (electric and diesel motors) AUE 11 UNI-EN 12845 units with 1 MXV series multi-stage vertical electric main pump UNI-EN 12845 units with 2 MXV series multi-stage vertical electric main pumps
Open the catalog to page 2AUE, AUD, AUED UNI-EN 12845 fire-fighting systems Construction 1) Main pump 2) Main pump 3) Jockey pump 4) Butterfly valve in suction section (on request only for installation with positive head) 5) Vacuometer 6) Pressure gauge in delivery section 7) Ball valve for draining 8) Adjusted diaphragm 9) Non-return valve (accessible) 10) Butterfly valve for capacity-check system (on request) 11) Manifold for flow meter (on request) 12) Flow meter (on request) 13) Butterfly valve or ball valve in delivery section 14) Delivery manifold 15) Test circuit (manual) (one for each pump) 16) Pressure...
Open the catalog to page 3AUE, AUD, AUED UNI-EN 12845 fire-fighting systems Construction Hydraulic components Units constructed in accordance with UNI-EN 12845 standards for automatic fire-fighting systems (with sprinkler) and according to UNI 10779 for fire-fighting systems with fire hydrants. The units may be composed of 1 or 2 main pumps. Units are fitted with a jockey pump, with which the system pressure level can be maintained without having to start the main pumps. Each main pump is fitted with: - Pressure and vacuum gauge in the suction section. - Butterfly valve in the suction section (on request only for...
Open the catalog to page 4Control panels UNI-EN 12845 fire-fighting systems Control panels Jockey pumps control panel Main pump control panel Main pump control panel Main pump control panel (Y/A starting) Main pump control panel (diesel motor) Control panel for remote control
Open the catalog to page 5AUE UNI-EN 12845 fire-fighting systems With 1 electric pump 30 20 With 2 electric pumps 60 40
Open the catalog to page 6UNI-EN 12845 units with 1 electric main pump
Open the catalog to page 7AUE 21 UNI-EN 12845 units with 2 electric main pumps Performance Unit designation Power Average capacity Max. capacity of one pump of one pump m /h
Open the catalog to page 8AUE 11 UNI-EN 12845 units with 1 electric main pump Dimensions Unit designation Main pump Jockey pump
Open the catalog to page 9AUE 21 UNI-EN 12845 units with 2 electric main pumps Dimensions Unit designation Main pump Jockey pump
Open the catalog to page 10AUD - AUED UNI-EN 12845 fire-fighting systems With 1 pump (diesel motor) 30 20 With 2 pumps (electric and diesel motors) 60 40
Open the catalog to page 11AUD 11 UNI-EN 12845 units with 1 main pump (diesel motor) Performance Unit designation Power Average capacity pump m3/h Pressure switch settings * Continuous rating overloading capacity, NA curve.
Open the catalog to page 12AUED 21 UNI-EN 12845 units with 2 main pumps (electric and diesel motors) Performance Motors power Unit designation Jockey pump Average capacity Max. capacity of one pump of one pump
Open the catalog to page 13AUD 11 UNI-EN 12845 units with 1 main pump (diesel motor) A max Unit designation Main pump AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD AUD Connections Jockey pump NG 5/18E NG 5/16E NG 6/18E NG 5/22E NG 5/18E NG 5/18E NG 5/16E NG 6/18E NG 6/18E NG 7/18/A NG 7/16/A NG 5/22E NG 5/18E NG 5/16E NG 6/18E NG 6/18E NG 5/16E NG 7/18/A NG 7/16/A NG 5/18E NG 5/18E NG 5/18E NG 5/16E NG 5/16E NG 6/18E NG 7/18/A NG 7/16/A NMD 25/190A/A NG 5/18E NG 5/18E NG 6/18E NG 6/18E NG...
Open the catalog to page 14AUED 21 UNI-EN 12845 units with 2 main pumps (electric and diesel motor) A max Unit designation Main pump AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED AUED Connections Diesel
Open the catalog to page 15AUE 11 MXV UNI-EN 12845 units with 1 multi-stage vertical electric main pump Performance Unit designation Power Pressure switch settings
Open the catalog to page 16AUE 21 MXV UNI-EN 12845 units with 2 multi-stage vertical electric main pumps U.S. g.p.m. Performance Unit designation Power Pressure switch settings Average capacity Max. capacity of one pump of one pump m /h 3
Open the catalog to page 17AUE 11 MXV UNI-EN 12845 units with 1 multi-stage vertical electric main pump Dimensions Unit designation * Suction connection jockey pump
Open the catalog to page 18AUE 21 MXV UNI-EN 12845 units with 2 multi-stage vertical electric main pumps Dimensions Unit designation * Suction connection jockey pump
Open the catalog to page 19AUE, AUD, AUED UNI-EN 12845 fire-fighting systems Characteristics of full-jet nozzles Capacity Water-jet range Characteristics of sprinkler nozzles Capacity Pressure
Open the catalog to page 20All Calpeda catalogs and technical brochures
-
Close Coupled Centrifugal Pumps
16 Pages
-
NM, NMS 60 Hz
16 Pages
-
NM, NMD
12 Pages
-
PMAT
1 Pages
-
Catalot 50 hz
624 Pages
-
catalog 60 hz
463 Pages
-
MP 60Hz
5 Pages
-
MP 50Hz
4 Pages
-
GM 10
2 Pages
-
GQN
4 Pages
-
E-MXP
8 Pages
-
CS, CS-R. FK
12 Pages
-
NCE EI
4 Pages
-
NCE H
5 Pages
-
NCE H F
5 Pages
-
NCE G F
5 Pages
-
NCED G F
5 Pages
-
NCE EL
4 Pages
-
NCE GS F
4 Pages
-
NCE ES
4 Pages
-
NCE PS
4 Pages
-
NCS3
3 Pages
-
NC3
4 Pages
-
NCD3
3 Pages
-
NCD
8 Pages
-
IDROMAT
2 Pages
-
EASYMAT
4 Pages
-
VARIOMAT
2 Pages
-
BS
90 Pages
-
QM, QT
25 Pages
-
MXH
12 Pages
-
N, N4
26 Pages
-
NM, NMD
12 Pages
-
GENERAL CATALOGUE 60HZ
378 Pages
-
GENERAL CATALOGUE 50HZ
584 Pages