CAL-PM
11Pages

{{requestButtons}}

Catalog excerpts

CAL-PM - 2

is a highly sophisticated and affordable device for permanent monitoring and PLC control system for compressed air applications. It covers all fields such as Remote Energy Management Systems, Data logger and Compressed Air Control System. System is doing real time access to data from any web browser for end user and their service partner. Save on energy costs ; Improve your energy efficiency ; Save your time and improve the organization ; Distribute costs in relation to actual consumption ; Improve the reliability of your equipment ; Improve forecast of energy consumption ; Improve your...

Open the catalog to page 2
CAL-PM - 3

Three in one - measuring, remote monitoring / alarming / reporting system and PLC control system for compressed air applications; WEB based application CALMS; Measuring data logger for compressed air system detail analysis; Energy management – Specific Power, M/T, CUSUM analysis; Detail Analysis of Compressed Air System with Report - done after customer confirmation, based on Auto Generated Warning of poor efficiency with potential savings calculation compared to best in class efficiency from CALMS knowledge data base; Expandable; Secure internet connection between CAL-PM and CALMS;...

Open the catalog to page 3
CAL-PM - 4

CALMS - PROCESS DIAGRAM CAL-PM base is placed in air compressor room. CAL-PM is connected to compressors and other measurement equipment. All analog and digital signals will be sent to the CALMS virtual cloud, if communication is established. An antenna must be connected, so CALMS – PM can communicate with virtual cloud. If there is a communication, all data will be shown on CALMS application, where you can analyze, control, monitor your compressed air system.

Open the catalog to page 4
CAL-PM - 5

FUNCTIONALITIES: Monitoring ; Energy monitoring control system-EMCS; Electricity consumption measurement (kWh); Direct data interchange / communication (Ethernet as standard or GPRS as options); Concentrator (analog inputs / outputs): connection of additional meters and sensors, tracking of process values, remote control of the devices Detail Analysis through service partner; Equipment performance analysis and alarming COMPRESSED AIR ENERGY MONITORING SYSTEM: CALMS PM Remote monitoring system for compressed air systems for 1-16 compressors; Data logging with 5 sec sampling rate; Permanent...

Open the catalog to page 5
CAL-PM - 6

ENERGY MANAGEMENT CONTROL SYSTEM – COMPRESSOR SEQUENCER OPTION: EMCS(Energy Management Control System) is an extra option and it is capable of controlling up to 16 compressors. The compressors may be fixed speed (ON/OFF) or variable speed (VSD). To activate EMCS function for regulation customer has to purchase this option. After purchasing the additional pages on the HMI are unlocked and further options and settings are accessible. Control System (EMCS) has to know which compressor is available for control and which is not. Each compressor has four main states: SPECIFICATIONS: CALMS-PM is...

Open the catalog to page 6
CAL-PM - 7

S-PLC Controller Processor 32bit, 400MHz flash memory micro SD 1GB, internal memory 64MB RAM Processor 32bit, 400MHz flash memory micro SD 1GB, internal memory 64MB RAM Processor ARM Cortex, Processor ARM Cortex, 1GHz flash memory 1GHz flash memory micro SD 1GB, internal micro SD 1GB, internal memory 1 GB DDR3 memory 1 GB DDR3 RAM RAM Real-time Ethernet, Real-time Ethernet, ADS TCP, Modbus TCP, ADS TCP, Modbus TCP, TCP/IP, UDP/IP, EAP TCP/IP, UDP/IP, EAP Real-time Ethernet, ADS Real-time Ethernet, TCP, Modbus ADS TCP, Modbus TCP, TCP,TCP/IP, UDP/IP, TCP/IP, UDP/IP, EAP EAP 3x Ethernet...

Open the catalog to page 7
CAL-PM - 8

Analog inputs Analog outputs (only in CAL-C-VSD) Digital inputs Digital outputs Power inputs (installed in CAL-C-xx) Current, voltage, effective power, apparent power, reactive power, frequency, energy, efficiency factor (cosφ)… Max 500VAC 3~ (ULX-N: max. 288VAC) Module coupler for E-bus terminals with Module coupler for E-bus terminals with integrated integrated digital I/O's: 4 digital inputs digital I/O's: 4 digital inputs 24VDC, filter 3.0ms, type 24VDC, filter 3.0ms, type 3 4 digital outputs 3 4 digital outputs 24VDC, 0.5A, 1-wire system E-bus 24VDC, 0.5A, 1-wire system E-bus power...

Open the catalog to page 8
CAL-PM - 9

ORDER CODES AND INFORMATION: Order code: Base module PM-2 for permanent monitoring and control (optional); Wall mounted Cabinet with Embedded PC-PLC system with 4G & Ethernet connection for up to 2 compressors - without CPM-C Compressor Number of compressors : 2 Measuring Data logger Inputs: 18 DI-Digital Inputs: 12 AI-Analog Inputs 4-20 mA: 4 DO-Digital outputs: 12 CI-Calculated Inputs: 8 PI-Power measuring Input: 2 Base module PM-4 for permanent monitoring and control (optional); Wall mounted Cabinet with Embedded PC-PLC system with LTE 4G & Ethernet connection for up to 4 compressors -...

Open the catalog to page 9
CAL-PM - 10

Order code: SIM LTE (3G/4G) subsctription per audit device – charged annualy Optics connection kit add-on for one compressors: 1-port EtherCAT multi-mode fibre optic junction, distance max. 2km EtherCAT coupler with ID switch, multimode fibre optic for E-bus terminals connectors, without optic cable 2 port expansion for RS422/RS485 modbus communication (for 2x4 devices) Remote module Ethernet – for standard LAN connection with expansion module option or remote connection via LAN. Expansion 4-channel analog input terminal 4-20mA, 12-bit, 4 x 2-wire system Expansion 8-channel analog input...

Open the catalog to page 10
CAL-PM - 11

LET'S WORK TOGETHER Central Europe CALMS AIR d.o.o. Dolenjska cesta 83 1000 Ljubljana, SI CALMS USA 9457 S University Blvd #710 Highlands Ranch CO 80126 CALMS Nordic AB Linnégatan 30 413 04 Göteborg Sweden

Open the catalog to page 11

All CALMS catalogs and technical brochures

  1. CAL-EDGE-0

    7 Pages

  2. CAL-EDGE-8

    7 Pages

  3. CFC series