Application: The HIFLEX CY (LIYCY) shielded cables are designed for data transmission, control, and connection, primarily for transmitting analog and digital signals in process-controlled facilities in measurement and control technology. They are suitable for both fixed installations and flexible applications without tensile stress.
Remarks: The cables conform to RoHS standards.
Construction:
  • Conductor Material: Bare copper strand.
  • Conductor Class: According to IEC 60228 class 5, except for 0.34mm² which is class 2.
  • Core Insulation: PVC.
  • Core Identification: According to DIN47100.
  • Stranding: Stranded in layers under PES tape.
  • Overall Shield: Tinned copper braid.
  • Outer Sheath: PVC, grey color.
  • Marking: HI-FLEX CY nxs - batch code - xxxm, where n is the number of conductors and s is the section.
Specifications:
  • Rated Voltage: Uo/U 300/500 V.
  • Testing Voltage: 1,500 V.
  • Conductor Resistance: Conforms to IEC 60228 class 5, except 0.34mm² class 2.
  • Insulation Resistance: Minimum 20 MΩ x km.
  • Minimum Bending Radius: Fixed 8 x d, moved 15 x d.
  • Operating Temperature: Fixed -30°C to +70°C, moved -5°C to +70°C.
  • Flame Retardant: Complies with NF C 32-070/C2 and IEC 60332-1.
  • CPR Level: Eca EN50575.
Dimensions and Weight: The document provides detailed dimensions and weights for various configurations of the cable, ranging from 2 x 0.25 mm² to 37 x 1.5 mm², with corresponding outer diameters and weights in kg/km.
Customization: Special versions, other dimensions, and different core and jacket colors are available upon request.
See more

Catalog excerpts

HIFLEX CY (LIYCY)-1

Couleur de la gaine gris Helicoidal, en couches concentriques sous ruban PES Tresse de cuivre etame PVC HI-FLEX CY nxs - N°lot - xxxm Avec n= Nbre de conducteur, s = section Construction Materiau du conducteur Classe du conducteur Isolant conducteur Assemblage Blindage Materiau gaine exterieure Donnees techniques Tension nominale Tension d’essai Resistance du conducteur Resistance d’isolement Rayon courbure min fixe Rayon courbure min mouv. Temp. service min/max fixe Temp. service min/max mouv. Comportement au feu CPR Level Cuivre nu selon IEC 60228 cl. 5 sauf 0.34mm2 (7x0.25mm) PVC selon DIN47100 Uo/U 300/500 V 1 500 V conforme a IEC 60228 classe 5 sauf 0.34mm2 classe 2 min. 20 MQ x km Structure conductor material conductor class core insulation core identification stranding overall shield outer sheath sheath colour marking Specifications rated voltage testing voltage conductor resistance insulation resistance min. bending radius fixed min. bending radius moved operat. temp. fixed min/max operat. temp. moved min/max burning behaviour CPR Level bare copper strand acc.to IEC 60228 cl. 5 excepted 0.34mm2 (7x0.25mm) PVC acc. to DIN 47100 stranded in layers under PES tape tinned copper braid PVC grey HI-FLEX CY nxs - batch code - xxxm with n= Nbr of conductor, s = section Uo/U 300/500 V 1 500 V conform to IEC 60228 class 5 excepted 0.34mm2 class 2 min. 20 MQ x km 8 x d 15 x d -30°C / +70°C -5°C / +70°C flame retardant NF C 32-070/C2 and IEC 60332-1 Eca EN50575 Ce document est confidentiel. Il est la propriete de CAE GROUPE. Le contenu et les images ne sont pas contractuels et peuvent changer a tout moment. Le document ne doit pas etre copie ou change sous aucune forme, completement ou en partie sans permission ecrite de CAE Groupe. www.cae-groupe.fr

 Open the catalog to page 1
HIFLEX CY (LIYCY)-2

HIFLEX CY (LIYCY) Cable de controle blindes - DIN47100 (type LiYCY) Shielded cable - DIN47100 (type LiYCY) FT 17N 27/09/2023 FR Dimensions n x mm2 Dimension n x mm2 Poids kg/km Weight kg/km Poids kg/km Weight kg/km • versions speciales, autres dimensions, sections, couleur de la gaine et des conducteurs sur demande • we are pleased to produce special versions, other dimensions, core and jacket colours on request. i>cae GROUPE Ce document est confidentiel. Il est la propriete de CAE GROUPE. Le contenu et les images ne sont pas contractuels et peuvent changer a tout moment. Le document ne doit...

 Open the catalog to page 2

All CAE GROUPE catalogs and technical brochures

  1. H03VVH2-F

    1  Page

  2. R2V

    2  Pages

  3. CBUS EIB

    1  Page

  4. CBUSEIBSHB

    1  Page

  5. RVFV

    2  Pages

  6. H1Z2Z2-K

    1  Page

  7. KZ

    2  Pages

  8. KU / KU B

    2  Pages

  9. SIAF PL J

    2  Pages

  10. SIHF

    2  Pages

  11. SIAF

    1  Page

  12. TROMPUR

    2  Pages

  13. FR-N1X1G1

    3  Pages

  14. H07RN-F

    2  Pages

  15. H05VV-F

    2  Pages

  16. KY

    2  Pages

  17. MN2XTREM

    1  Page

  18. UL1007-1569

    1  Page

  19. UL1015

    1  Page

  20. SF600P4PUR

    1  Page

  21. SF6004PUR

    1  Page

  22. SFU100XP4PUR

    1  Page

  23. SFU1004PUR

    1  Page

  24. PNET A

    1  Page

  25. RG316U

    1  Page

  26. RG 174 U

    1  Page

  27. MPI22A (MPI)

    2  Pages

  28. MP22E (MCP)

    2  Pages

  29. MC22E (2xx2E)

    2  Pages

  30. CBUS D

    2  Pages

  31. CAEINSTRUM

    3  Pages

  32. CAELIFLEX-1KV

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.
About DirectIndustry
DirectIndustry is a marketplace that offers B2B players a complete experience, from product sourcing to purchase. DirectIndustry is an entity of VirtualExpo Group.