Application
CAELIFLEX B cables are designed for use as power, control, and connecting cables in electrical installations. They are suitable for fixed and flexible applications without tensile stress and without defined cable routing. These cables can be used in dry, humid, and wet environments, and outdoors only with UV protection. They are not suitable for underground installation.
Remarks
The cables conform to RoHS standards.
Construction
The cables feature bare copper conductors, class 5 according to IEC 60228, with PVC insulation. The core identification is black numbered with a yellow/green conductor. The conductors are stranded in layers and have an overall shield of tinned copper braid. The outer sheath is made of PVC and is grey in color. The sheath is marked with CAELIFLEX B, the number of conductors, section, batch code, and length.
Specifications
The rated voltage is 300/500V, with a testing voltage of 4,000V. The conductor resistance conforms to IEC 60228 class 5, and the insulation resistance is a minimum of 20 MΩ x km. The minimum bending radius is 7 times the diameter for fixed installations and 15 times for movable installations. The operating temperature ranges from -40°C to +80°C for fixed installations and -5°C to +70°C for movable installations. The cables are flame retardant according to IEC 60332-1.
Dimensions and Weight
The document provides detailed dimensions and weights for various configurations of the cables, ranging from 2 to 34 conductors with cross-sectional areas from 0.5 mm² to 35 mm². The outer diameter and weight per kilometer are specified for each configuration.
Customization
Special versions, including different dimensions, sections, and colors for the sheath and conductors, are available upon request.
See more

Catalog excerpts

CAELIFLEX B (YSLCY-JZ)-1

FT 16 27/09/2023 FR Application Ces cables sont utilises comme cables d'energie, de commande, de liaison et de raccordement dans les equipements electriques en pose fixe et utilisation mobile, en mouvement libre, sans effort de traction et sans guidage force. I ls peuvent etre poses en milieu sec ou humide, a l'exterieur uniquement avec une protection UV et ne doivent en aucun cas etre poses sous terre. Application power, control and connecting cable in electrical facilities for fixed laying and flexible applications without tensile stress and without defined cable routing. Suitable for use in dry, humid and wet rooms. Outdoor use only with UV-protection, no laying in underground. Ce document est confidentiel. Il est la propriete de CAE GROUPE. Le contenu et les images ne sont pas contractuels et peuvent changer a tout moment. Le document ne doit pas etre copie ou change sous aucune forme, completement ou en partie sans permission ecrite de CAE Groupe. www.cae-groupe.fr Construction Materiau du conducteur Classe du conducteur Isolant conducteur Reperage Assemblage Blindage general Materiau gaine exterieure Couleur de la gaine Marquage sur gaine Donnees techniques Tension nominale Tension d’essai Resistance du conducteur Resistance d’isolement Cuivre nu selon IEC 60228 cl. 5 PVC Noir numerate + vert/jaune conducteurs assembles en couche tresse de cuivre etame, PVC gris CAELIFLEX B - nGs - N°lot - xxxm Avec n= Nbre de conducteur, s = section Structure conductor material conductor class core insulation core identification stranding overall shield outer sheath sheath colour marking Specifications rated voltage testing voltage conductor resistance insulation resistance bare copper strand acc.to IEC 60228 cl. 5 PVC Black numbered + yellow/green conductor stranded in layer copper braid tinned, PVC grey CAELIFLEX B - nGs - batch code - xxxm with n= Nbr de conductor, s = section Rayon courbure min fixe Rayon courbure min mouv. Temp. service min/max fixe Temp. service min/max mouv. Comportement au feu min. bending radius fixed min. bending radius moved Operat.temp.fixed min/max operat. temp. moved min/max burning behavior

 Open the catalog to page 1
CAELIFLEX B (YSLCY-JZ)-2

Poids kg/km Weight kg/km Poids kg/km Weight kg/km • versions spéciales, autres dimensions, sections, couleur de la gaine et des conducteurs sur demande • we are pleased to produce special versions, other dimensions, core and jacket colours on request. Ce document est confidentiel. Il est la propriété de CAE GROUPE. Le contenu et les images ne sont pas contractuels et peuvent changer à tout moment. Le document ne doit pas être copié ou changé sous aucune forme, complètement ou en partie sans permission écrite de CAE Group

 Open the catalog to page 2

All CAE GROUPE catalogs and technical brochures

  1. H03VVH2-F

    1  Page

  2. R2V

    2  Pages

  3. CBUS EIB

    1  Page

  4. CBUSEIBSHB

    1  Page

  5. RVFV

    2  Pages

  6. H1Z2Z2-K

    1  Page

  7. KZ

    2  Pages

  8. KU / KU B

    2  Pages

  9. SIAF PL J

    2  Pages

  10. SIHF

    2  Pages

  11. SIAF

    1  Page

  12. TROMPUR

    2  Pages

  13. FR-N1X1G1

    3  Pages

  14. H07RN-F

    2  Pages

  15. H05VV-F

    2  Pages

  16. KY

    2  Pages

  17. MN2XTREM

    1  Page

  18. UL1007-1569

    1  Page

  19. UL1015

    1  Page

  20. SF600P4PUR

    1  Page

  21. SF6004PUR

    1  Page

  22. SFU100XP4PUR

    1  Page

  23. SFU1004PUR

    1  Page

  24. PNET A

    1  Page

  25. RG316U

    1  Page

  26. RG 174 U

    1  Page

  27. MPI22A (MPI)

    2  Pages

  28. MP22E (MCP)

    2  Pages

  29. MC22E (2xx2E)

    2  Pages

  30. CBUS D

    2  Pages

  31. CAEINSTRUM

    3  Pages

  32. CAELIFLEX-1KV

    2  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.