Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications. fEATurES & bENEfITS • 10 year design life @ 25˚C • Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintenance. • Data Centers • Network Operations Centers • Industrial Process Control Facilities • Patented Long Life Alloy having the lowest calcium levels in the industry minimizing grid growth, reducing gassing, and extending battery life. • Internet Hosting Sites • Semiconductor Manufacturing • Banks & Financial Markets • Patented UL Recognized Flamearresting vents in each cell for safety and long life. • Power Generation Plants • Hospitals & Testing Laboratories • Designed with the same recombination, thermal runaway prevention, gassing and flame retardant characteristics of the Bellcore 4228 compliant Dynasty Telecom products. • Emergency 911 Response Centers • Flame retardant polypropylene case and cover compliant with UL94V-2 • Proprietary Fixed Orifice Plate Pasting technology applying active materials on both sides of the grid for consistent cell-to-cell performance, higher capacity and uniform grid protection. • Thermally welded case-to-cover bond to eliminate leakage. • Can be operated in any orientation. Upright, side, or end mounting recommended. • Not restricted for air transport - Complies with IATA/ICAO Special Provisions A67. • Not restricted for surface transport Classified as non-hazardous material as related to DOT-CFR Title 49 parts 171-189. • Not restricted for water transport Classified as non-hazardous material per IMDG Amendment 27. • Eurobat Classification: Long life TECHNICAL DATA Constant Power Discharge Ratings - Watts per Cell @ 25°C (77°F) Operating Time (in minutes) to 1.67 Volts per Cell Nominal Voltage 20 hour IEC Rating: rate to 1.75 10 hour rate VPC @ to 1.80 VPC 25°C @ 20°C 147 AH 135 AH IEC IEC Short Circuit Current Internal Resistance (Amps) (mOhms) 3640 Dynasty* Short Circuit Current (Amps) @ .1 Sec 6448 * Same method as High Rate Series & High Rate Max Series Additional ratings and application information are available in the Battery Selection Program found at www.cdstandbypower.net

Open the catalog to page 1
UPS High Rate Max Series - 2

SPECIfICATIONS Operating Temperature range with temperature compensation Nominal Operating Temperature range recommended Maximum Charging Current Limit float Charging Voltage Maximum AC ripple (Charger) 0.5% RMS or 1.5% P-P of float charge voltage recommended for best results. Max voltage allowed = 1.4% RMS (4% P-P) Max current allowed = C/20 Self Discharge Battery can be stored up to 6 months at 77°F (25°C) before a freshening charge is required. Batteries stored at temperatures greater than 77°F (25°C) will require recharge sooner than batteries stored at lower temperatures. See C&D...

Open the catalog to page 2

All C&D Technologies catalogs and technical brochures

  1. LCT-HP

    2 Pages

  2. LCZ

    2 Pages

  3. XDJ

    4 Pages

  4. L83_0117

    11 Pages

  5. Sageon® III

    4 Pages

  6. ARR Legacy

    4 Pages

  7. Lithium Ion

    4 Pages

  8. BBA-160RT

    2 Pages

  9. SGC Series

    4 Pages

  10. LCT II 1700

    2 Pages

Archived catalogs

  1. DC/DC Databook

    36 Pages