PURE LEAD PLUS Valve Regulated Lead Acid Battery Designed for UPS Standby Power Applications 305-545 Watts per Cell FEATURES & bENEFITS APPLICATIONS • Data Centers • Network Operations Centers • Industrial Process Control Facilities • Internet Housing Sites • Semiconductor Manufacturing • Banks & Financial Markets • Power Generation Plants • Hospitals & Testing Laboratories • Emergency 911 Response Centers • Pure Lead Paste for long life and stable performance • Flame retardant polypropylene case and cover compliant with UL94-V2 • Industry Leading Warranty • Advanced proprietary plate processing technology for high active material utilization - results in high energy density and low float currents • Extended life at elevated ambient temperatures • 10 year design life @ 25˚C • Absorbent Glass Mat (AGM) technology for efficient gas recombination of up to 99% and freedom from electrolyte maintenance • Patented Long Life Alloy having the lowest calcium levels in the industry minimizing grid growth, reducing gassing, and extending battery life • Patented UL Recognized Flamearresting vents in each cell for safety and long life • Designed with the same recombination, thermal runaway prevention, gassing and flame retardant characteristics of the Bellcore 4228 compliant Dynasty Telecom products • Thermally welded and helium leak tested case-to-cover bond to ensure a robust leak proof seal • Can be operated in any orientation. Upright, side or end mounting recommended • Not restricted for air transport - Complies with IATA/ICAO Special Provisions A67 • Not restricted for surface transport Classified as non-hazardous material as related to DOT-CFR Title 49 parts 171-189 • Not restricted for water transport Classified as non-hazardous material per IMDG Amendment 27
Open the catalog to page 1TEChNICAL DATA Constant Power Discharge Ratings - Watts per Cell @ 77°F (25°F) Operating Time (in minutes) to 1.67 Volts per Cell * Nominal 20 hr rate to 1.75 VPC in Ampere-Hours. SPECIFICATIONS Operating Temperature Range with temperature compensation Nominal Operating Temperature Range Recommended Maximum Charging Current Limit Float Charging Voltage Maximum AC Ripple (Charger) 0.5% RMS or 1.5% P-P of float charge voltage recommended for best results. Max voltage allowed = 1.4% RMS (4% P-P) Max current allowed = C/20 (20 hr. rate) Self Discharge Battery can be stored up to 6 months at...
Open the catalog to page 2Battery Termination *All dimensions in inches [mm]. All dimensions are for reference only. Contact a C&D Representative for complete dimension information. NOTE: Batteries to be mounted with 0.5 in [1.25 cm] spacing minimum and free air ventilation. UPS12-305PLP Constant Power Discharge Ratings - Watts Per Cell @ 77˚F (25˚C) Operating Time to End Point Voltage (in minutes) End Point Volts/Cell 1.75 1.70 1.67 1.65 1.60 Constant Current Discharge Ratings - Amperes @ 77˚F (25˚C) Operating Time to End Point Voltage (in hours) End Point Volts/Cell 1.85 1.80 1.75 Note: Batteries to be mounted...
Open the catalog to page 3UPS UPS12-355PLP Constant Power Discharge Ratings - Watts Per Cell @ 77˚F (25˚C) Operating Time to End Point Voltage (in minutes) End Point Volts/Cell 1.75 1.70 1.67 1.65 1.60 Constant Current Discharge Ratings - Amperes @ 77˚F (25˚C) Operating Time to End Point Voltage (in hours) End Point Volts/Cell 1.85 1.80 1.75 Note: Batteries to be mounted with 0.5 in. (1.25 cm) spacing minimum and free air ventilation. Specifications subject to change without notification. Above ratings do not include interunit connector voltage drops. UPS12-405PLP Constant Power Discharge Ratings - Watts Per Cell @...
Open the catalog to page 4UPS UPS12-495PLP Constant Power Discharge Ratings - Watts Per Cell @ 77˚F (25˚C) Operating Time to End Point Voltage (in minutes) End Point Volts/Cell 1.75 1.70 1.67 1.65 1.60 Constant Current Discharge Ratings - Amperes @ 77˚F (25˚C) Operating Time to End Point Voltage (in hours) End Point Volts/Cell 1.85 1.80 1.75 Note: Batteries to be mounted with 0.5 in. (1.25 cm) spacing minimum and free air ventilation. Specifications subject to change without notification. Above ratings do not include interunit connector voltage drops. UPS12-545PLP Constant Power Discharge Ratings - Watts Per Cell @...
Open the catalog to page 5TOP TERMINAL VRLA bATTERY RACKS FOR UPS, TEL, SGC AND VRS TOP TERMINAL BATTERIES C&D Technologies Top Terminal VRLA battery racks are designed to be durable, and easy to install. Engineered for use with most C&D Top Terminal battery models, these racks fit a wide variety of applications. FEATURES & bENEFITS APPLICATIONS • UPS - Data Centers - Industrial Process Control Facilities - Emergency 911 Response Centers - Air Traffic Control Centers Switchgear & Control Renewable Energy For additional information see brochure 12-1117. FLEXIbLE • 1 tier to 5 tier models available, 4 to 5 batteries...
Open the catalog to page 6All C&D Technologies catalogs and technical brochures
-
FLOODED BATTERY RACKS
9 Pages
-
LI TEL 48-170 C
4 Pages
-
LCT-HP
2 Pages
-
LCZ
2 Pages
-
XT® / XT Plus® / XTH series
6 Pages
-
XDJ
4 Pages
-
L83_0117
11 Pages
-
JC LEAD-CALCIUM
2 Pages
-
DJU Lead-Calcium Battery
2 Pages
-
UPS High Rate Max Series
2 Pages
-
LIBERTY® DCS
4 Pages
-
Sageon® III
4 Pages
-
ARR Legacy
4 Pages
-
Lithium Ion
4 Pages
-
BBA-160RT
2 Pages
-
DJ Lead-Calcium Batteries
2 Pages
-
XT® Series and XT Plus®
6 Pages
-
SGC Series
4 Pages
-
DC-AC Inverters
2 Pages
-
Micro ARE Series
4 Pages
-
Sageon™ Power Module
2 Pages
-
Sageon™ Power Module
2 Pages
-
Sageon Micro™ Power Module
4 Pages
-
LIBERTY® Series 1000
6 Pages
-
MCT II Batteries
4 Pages
-
LCT II 1700
2 Pages
Archived catalogs
-
C&D Technologies Databook
22 Pages
-
DC/DC Databook
36 Pages