Operation Manual - RESISTOMAT Model 2311-1

OPERATION MANUALVersion 1.0RESISTOMAT®Model 2311 Manufacturer: prazisionsmesstechnik gmbh & co. kg prazisionsmesstechnik gmbh & co. kg All rights reserved Talstrasse 1 - 5 Postfach 1432 Germany Germany Fax: +49 7224 64588 Email: [email protected] www.burster.com

 Open the catalog to page 1
Operation Manual - RESISTOMAT Model 2311-2

Warranty disclaimer All information in the present documentation was prepared and compiled with great care and reproduced in accordance with effective control measures. No warranty is provided for freedom from errors. We reserve the right to make technical changes. The present information as well as the corresponding technical data can change without notice. Reproduction of any part of this documentation or its processing or revision using electronic systems is prohibited without the manufacturer’s prior written approval. Components, devices and measurement sensors made by burster präzisionsmesstechnik...

 Open the catalog to page 2
Operation Manual - RESISTOMAT Model 2311-3

EU-Konformitatserklarung (nach en iso/iec 17050-1:2010) Name des Ausstellers: Issuer's name: Anschrift des Ausstellers: Issuer's address: burster praz s onsmesstechmk gmbh & co kg Talstr. 1-5 RESISTOMAT® zur Highspeed-Widerstandsmessung in der Automation RESISTOMAT® for high-speed resistance measurement in automation Model number/type: Diese Erklarung beinhaltet obengenannte Produkte mil alien Optionen This declaration covers all options of the above product(s) Das oben beschriebene Produkt ist konform mit den Anforderungen der folgenden Dokumente: The object of the declaration described above...

 Open the catalog to page 3
Operation Manual - RESISTOMAT Model 2311-8

RESISTOMAT® 2311 1 For your safety The following symbols on the RESISTOMAT® 2311 and in this operation manual warn of hazards. 1.1 Symbols used in the operation manual The following signal words are used in the operation manual according to the specified hazard classification. The signal words introduce warnings that must be followed and acted upon with care to prevent accidents, injuries and damage to property. DANGER High degree of risk: indicates a hazardous situation which, if not avoided, will result in death or serious injury. Moderate degree of risk: indicates a hazardous situation which,...

 Open the catalog to page 8
Operation Manual - RESISTOMAT Model 2311-10

RESISTOMAT® 23112 Introduction IMPORTANT: Read the operation manual carefully before using the equipment, and keep it for future reference. The operation manual must be read carefully before putting the device into service or carrying out maintenance or other work on the RESISTOMAT® model 2311. All safety instructions and safety regulations relating to accessory equipment / attachments must be observed to ensure safe and proper handling of the device. Only qualified personnel may perform maintenance work on electrical components (see section 2.5 Personnel). These safety instructions must be included...

 Open the catalog to page 10
Operation Manual - RESISTOMAT Model 2311-11

RESISTOMAT® 2311 2.3 Download the test certificate You have the option to download the test certificate for your model 2311 RESISTOMAT® online. Please use the following link https://www.burster.com/en/service-calibration/download-your-test-and-calibration-certificates-here. You can then download the test certificate directly by entering the serial number. The following requirements must be met when storing the RESISTOMAT® 2311: • Store at temperatures between -10 °C and +60 °C • The unit must be packed in clean packaging The following requirements must be met when operating the RESISTOMAT® 2311:...

 Open the catalog to page 11
Operation Manual - RESISTOMAT Model 2311-12

DANGER Electric shock hazard! Disconnect the RESISTOMAT® 2311 from the power supply before cleaning. Disconnect the RESISTOMAT® 2311 from the power supply and use a dry cloth to clean it. NOTICE Do not immerse the RESISTOMAT®2311 in water or hold it under running water. Do not use strong cleaning agents as these may damage the instrument. Use a damp cloth to clean the device. Qualified personnel are persons who, due to their training, experience, instruction and knowledge of the relevant standards, regulations, accident prevention rules and working conditions have been authorized by the person...

 Open the catalog to page 12
Operation Manual - RESISTOMAT Model 2311-13

DANGER Electric shock hazard! Never switch on the device if it shows signs of damage incurred in transit. Only ever use the device under the conditions specified in this operating manual. Inspect the device for damage. If you suspect that the device has been damaged during shipping, notify the delivery company within 72 hours. The packaging should be retained for examination by a representative of the manufacturer and/or the delivery company. The RESISTOMAT® 2311 should be shipped only in its original packaging or in packaging capable of providing an equivalent degree of protection. burster präzisionsmesstechnik...

 Open the catalog to page 13
Operation Manual - RESISTOMAT Model 2311-14

RESISTOMAT® 23112.10 Using the device for the first time If condensation has formed on the device, make sure that the device is completely dry (including inside) Connect the device to a standard grounded power outlet using the power lead supplied. 2.10.1 Setup and installation, storage • Ensure sufficient air circulation (prevent heat build-up). • Avoid positioning the device on surfaces such as carpets, blankets or near materials that could impede air circulation. • Operate only in a horizontal position. • Keep the device away from devices, machinery and equipment that generate strong magnetic...

 Open the catalog to page 14
Operation Manual - RESISTOMAT Model 2311-15

RESISTOMAT® 2311 German error message For further information, please refer to section 2.2 “Customer Service” on page 10.

 Open the catalog to page 15
Operation Manual - RESISTOMAT Model 2311-16

Device concept Please refer to the current data sheet for the RESISTOMAT® 2311 for full details of dimensions, weight, degree of protection etc. You can find this and other related information on the product page. Functional scope The RESISTOMAT® 2311 uses the 4-wire measuring method (Kelvin measuring method) to precisely measure and evaluate the ohmic resistances of test objects with and without an inductive component in partially or fully automated production processes, laboratory applications, functional tests and at manual workstations. With the RESISTOMAT® model 2311, the operating modes...