OPERATION MANUALTRANS CAL Model 7281 Manufacturer: burster burster prazisionsmesstechnik gmbh & co kg prazisionsmesstechnik gmbh & co kg All rights reserved TalstraGe 1 - 5 Postfach 1432 Germany Germany Valid from: Fax.: (+49) 07224 645-88 E-Mail: [email protected] www.burster.com
Open the catalog to page 1Exclusion of warranty liability for operating manuals All information in the present documentation was prepared and compiled with great care and reproduced subject to effective control measures. No warranty is provided for freedom from errors. We reserve the right to make technical changes. The present information as well as the corresponding technical data can change without notice. Reproduction of any part of this documentation or its processing or revision using electronic systems is prohibited without the manufacturer‘s prior written approval. Components, devices and measured value sensors...
Open the catalog to page 2The measurement solution. EU-Konformitatserklarung (nach en iso/iec 17050-1:2010) EU-Declaration of conformity (in accordance with EN ISO/IEC 17050-1:2010) Name des Ausstellers: burster prazisionsmesstechnik gmbh & co kg Issuer’s name: Anschrift des Ausstellers: Talstr. 1-5 Issuer’s address: 76593 Gernsbach, Germany Gegenstand der Erklarung: Mobiles Hochprazisions-Kalibrier- und Prufgerat fur mechanische und elektrische GroSen Object of the declaration: Mobile High-Precision Calibrator and Testing Device for mechanical and electrical Model number / type: Diese Erklarung beinhaltet obengenannte...
Open the catalog to page 34.4.1. Sub-D female connector (measurement, sensor test,
Open the catalog to page 49. Operation mode "Device Test" with strain 11.2.1. Strain gauge / potentiometer / transmitter / voltage measurement
Open the catalog to page 6Safety instructions On the device TRANS CAL model 7281 and in this manual the following symbols warn about risks: Symbols in this manual Signal words The following signal words are used in the operating manual according to the specified hazard classification. DANGER DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. WARNING WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. CAUTION CAUTION indicates a hazard with a low level or risk which, if not avoided, could result...
Open the catalog to page 7TRANS CAL 7281 1.2. Symbols on the device Richtige Schallerstellung schutzt vor Gertitedefekt! Correct switch position protects device from damages! Read the text on the label. In the battery compartment is a sliding switch. It is vital to set this switch correctly to rechargeable or non-rechargeable battery operation. Before switching on, make sure that the rechargeable/non-rechargeable batteries are inserted correctly and that the sliding switch in the battery compartment is set to the correct position, to avoid damage to the instrument.
Open the catalog to page 8IMPORTANT: Read the operating manual carefully before using the equipment, and keep for future reference. The TRANS CAL model 7281 can be used wherever there is a need to perform high-precision, on-site calibrations of sensing components used in equipment such as presses, torque tools or pressureregulating systems. An optional factory calibration certificate or German-accredited DKD/DAkkS calibration certificate can be provided when the TRANS CAL model 7281 needs to be used as a reference. This provides a quick and cost-effective way of assessing a system with traceable documentation of measurement...
Open the catalog to page 9TRANS CAL 72812.2. Customer service 2.2.1. Customer service department If you need to ask about repairs, please telephone our Service department on +49 7224 645-53. Please have the serial number to hand. The serial number is essential to establishing the definite technical status of the instrument and providing help quickly. You will find the serial number on the type plate of the TRANS CAL model 7281 instrument. If you have any questions relating to the TRANS CAL model 7281, please contact your representative or go directly to burster prazisionsmesstechnik gmbh & co. kg. burster prazisionsmesstechnik...
Open the catalog to page 10TRANS CAL 7281 Note: The following requirements must be met when operating the TRANS CAL model 7281. • Use only in enclosed spaces • Rated temperature range between 0 to 40 °C • Maximum height above sea level 2000 m • Air humidity of 80% at up to 31 °C, decreasing linearly above that temperature to 50% at T (no condensation). • Transient overvoltage category: CAT II • Supply voltage: 4 x AA battery or 10 to 28 VDC (see section "3.2. Voltage supply"). The TRANS CAL model 7281 does not pose a hazard if used within its specification and in accordance with the safety regulations. The manufacturer...
Open the catalog to page 11TRANS CAL 72812.5. Scope of delivery • 1x TRANS CAL model 7281 • 1x Power supply for model 7281, 100 - 240 VAC, 47 ... 63 Hz, Output: 12 VDC / 0,83 A • 4x Size AA cells (Mignon-Akku) • User’s manual digital on the homepage (www.burster.com) • Data Sheet digital on the homepage (www.burster.com) Inspect the TRANS CAL model 7281 carefully for damage. If you suspect that the TRANS CAL model 7281 has been damaged during shipping, notify the delivery company within 72 The packaging should be retained for examination by a representative of the manufacturer and/or the delivery company. The TRANS CAL...
Open the catalog to page 12If you open or dismantle the TRANS CAL model 7281 during the warranty period, this will void the warranty immediately. The TRANS CAL model 7281 does not contain any parts that are intended to be serviced by the user. Only the manufacturer's own qualified personnel are permitted to open the TRANS CAL model 7281. This excludes the cover to the battery compartment. It is forbidden to make any modification to the TRANS CAL model 7281 without our written permission. We cannot accept liability in the event of such action.
Open the catalog to page 13TRANS CAL 72813. Device design 220 x 100 x 52 mm ca. 850 g IP 40 Protection type: Supply voltage: Nominal temperature range: Storage temperature range: (for further information please see chapter „11. Technical Data“) The TRANS CAL model 7281 is available in two different versions: the TRANS CAL model 7281-V0000 and the TRANS CAL model 7281-V0001. These versions have a different range of functions: The TRANS CAL model 7281 can be operated using batteries (rechargeable or non-rechargeable) or using a power adapter. Switching between the two supply options for the TRANS CAL model 7281 is done purely...
Open the catalog to page 145 Pages
7 Pages
76 Pages
8 Pages
6 Pages
7 Pages
25 Pages
5 Pages
6 Pages
5 Pages
6 Pages
5 Pages
5 Pages
2 Pages
2 Pages
6 Pages
2 Pages
25 Pages
5 Pages
9 Pages
7 Pages
5 Pages
6 Pages
6 Pages
7 Pages
7 Pages
2 Pages
7 Pages
7 Pages
7 Pages
9 Pages
1 Page
6 Pages
6 Pages
14 Pages
2 Pages
6 Pages
5 Pages
6 Pages
7 Pages
2 Pages
2 Pages
2 Pages
7 Pages
8 Pages
7 Pages
2 Pages
2 Pages
7 Pages
5 Pages
6 Pages
7 Pages
5 Pages
2 Pages
6 Pages
5 Pages
8 Pages
9 Pages
7 Pages
6 Pages
7 Pages
7 Pages
6 Pages
6 Pages
11 Pages
2 Pages
2 Pages
1 Page
1 Page
2 Pages
2 Pages
1 Page
5 Pages
76 Pages
2 Pages
4 Pages
4 Pages
5 Pages
2 Pages
4 Pages
6 Pages