Operation Manual Fieldbus controller Model 9251
65Pages

{{requestButtons}}

Catalog excerpts

Operation Manual Fieldbus controller Model 9251 - 1

Valid from: OPERATION MANUAL Fieldbus controller Model 9251 burster prazisionsmesstechnik gmbh & co kg All rights reserved Manufacturer: burster prazisionsmesstechnik gmbh & co kg Talstr. 1-5 Postfach 1432 Germany Germany

Open the catalog to page 1
Operation Manual Fieldbus controller Model 9251 - 2

Warranty disclaimer All information in the present documentation was prepared and compiled with great care and reproduced in accordance with effective control measures. No warranty is provided for freedom from errors. We reserve the right to make technical changes. The present information as well as the corresponding technical data can change without notice. Reproduction of any part of this documentation or its processing or revision using electronic systems is prohibited without the manufacturer's prior written approval. Components, devices and measurement sensors made by burster...

Open the catalog to page 2
Operation Manual Fieldbus controller Model 9251 - 3

Fieldbus-Controller Model 9251 EU-Konformitatserklarung (nach en iso/iec 17050-1:2010) EU-Declaration of conformity (in accordance with EN ISO/IEC 17050-1:2010) Name des Ausstellers: Issuer's name: Anschrift des Ausstellers: Issuer's address: Gegenstand der Erklarung: Object of the declaration: burster prazisionsmesstechnik gmbh & co kg Talstr. 1-5 76593 Gernsbach, Germany Buscontroller Buscontroller Model number /type: Diese Erklarung beinhaltet obengenannte Produkte mit alien Optionen This declaration covers all options of the above product(s) Das oben beschriebene Produkt ist konform mit...

Open the catalog to page 3
Operation Manual Fieldbus controller Model 9251 - 4

Fieldbus-Controller Model 9251 Declaration of Conformity (DOC) Reference Information File Number 12231.01 Part 1 oM Year Last Issued: 2022 Continues in effect so long as the named entity (i) remans an ODVA Licensee Vendor far the ODVA Length of technology; es; defined by the above specif cation(s); { ) continues bUH is user responsibilities as defined Validity; in rtsTerms of Usage Agreement with ODVA; and (iii)lheCF Identityfotthe Produces) remains identical to those enumerated in this Declaration of Conformity. ODVA Licensed Vendor to Whom this DOC has Been Issued Entity Name: burster...

Open the catalog to page 4
Operation Manual Fieldbus controller Model 9251 - 8

7.3.2 Data protocol for data transmission from the 9251 fieldbus controller to the control system 38 7.3.4 Data protocol for data transmission from the control system to the 9251 fieldbus controller 40 7.4.2 Acyclical data 9250 7.4.3 Acyclical data 9250 7.4.4 Acyclical data 9250 7.4.5 Acyclical data 9250 7.4.6 Acyclical data 9250 7.4.7 Acyclical data 9250 7.4.8 Acyclical data 9250 7.4.9 Acyclical data 9250 8.6.2 Data protocol for cyclic data transmission from the 9251 fieldbus controller to the scanner 51

Open the catalog to page 8
Operation Manual Fieldbus controller Model 9251 - 10

Fieldbus-Controller Model 9251 1 For your safety The following symbols on the model 9251 fieldbus controller and in this operation manual warn of hazards. 1.1 Symbols used in the operating manual 1.1.1 Signal words The following signal words are used in the operating manual according to the specified hazard classification. DANGER High degree of risk: indicates a hazardous situation which, if not avoided, will result in death or serious injury. A WARNING Moderate degree of risk: indicates a hazardous situation which, if not avoided, may result in death or serious injury. A CAUTION Low degree...

Open the catalog to page 10
Operation Manual Fieldbus controller Model 9251 - 11

Fieldbus-Controller Model 9251 1.1.2 Pictograms

Open the catalog to page 11
Operation Manual Fieldbus controller Model 9251 - 12

Fieldbus-Controller Model 9251 2 Introduction IMPORTANT: Read the operating manual carefully before using the equipment, and keep for future reference. • Only use the model 9251 fieldbus controller outside of potentially explosive A areas. • The model 9251 fieldbus controller is not intended as a substitute for safety devices and protective equipment. Use safety devices and protective equipment. ' • The model 9251 fieldbus controller is not intended for use in medical applications or where people are at risk. • Do not connect voltages that are higher than the specification allows. • Not for...

Open the catalog to page 12
Operation Manual Fieldbus controller Model 9251 - 13

Fieldbus-Controller Model 9251 2.2.2 Contact person If you have any questions relating to the model 9251 fieldbus controller, please go directly to burster prazisionsmesstechnik gmbh & co kg, or if outside Germany, please contact your burster agent (see also www .burster.com). Head office burster prazisionsmesstechnik gmbh & co kg Talstr. 1-5 76593 Gernsbach GERMANY Phone: +49 7224 645-0 Email: info@burster.de 2.3 Download the test certificate You have the option to download the test certificate for your model 9251 fieldbus controller online. To do this, use the following link...

Open the catalog to page 13
Operation Manual Fieldbus controller Model 9251 - 14

Fieldbus-Controller Model 9251 2.4.3 Restrictions on use A DANGER The model 9251 fieldbus controller is not intended as a substitute for safety devices and protective equipment. Use safety devices and protective equipment. The model 9251 fieldbus controller does not pose a hazard if used within its specification and in accordance with the safety regulations. The manufacturer does not accept liability for any personal injury or property damage arising from misinterpretation of measurement results. 2.4.4 Cleaning A DANGER Electrical shock hazard Disconnect the model 9251 fieldbus controller...

Open the catalog to page 14
Operation Manual Fieldbus controller Model 9251 - 15

DANGER Electrical shock hazard Never switch on the model 9251 fieldbus controller if it shows signs of damage incurred in transit. Only ever use the model 9251 fieldbus controller under the conditions specified in this operating manual. Inspect the model 9251 fieldbus controller for damage. If you suspect that the unit has been damaged during shipping, notify the delivery company within 72 hours. The packaging should be retained for examination by a representative of the manufacturer and/or the delivery company. The model 9251 fieldbus controller should be shipped only in its original...

Open the catalog to page 15
Operation Manual Fieldbus controller Model 9251 - 16

Fieldbus-Controller Model 92513 Device concept Please refer to the model 9251 fieldbus controller data sheet for full details of dimensions, weight, degree of protection etc. 3.1 Functional scope The model 9251 fieldbus controller serves as a bridge between cascadable model 9250 universal instrumentation amplifiers and Ethernet-based fieldbuses such as PROFINET, EtherCAT and EtherNet/IP. Up to eight model 9250 instrumentation amplifiers, bus-compatible version, can be connected to the model 9251 fieldbus controller. The scaled measured values are read simultaneously in the real-time data of...