Catalog excerpts
OPERATION MANUAL DIGIFORCE® Model 9311 © 2018 burster praezisionsmesstechnik gmbh & co kg All rights reserved Manufacturer: burster praezisionsmesstechnik gmbh & co kg Talstr. 1 - 5 P.O. Box 1432 Germany Germany Tel.: +49-7224-645-0 Fax: +49-7224-645-88 Email: info@burster.com www.burster.com
Open the catalog to page 1Warranty disclaimer All information in the present documentation was prepared and compiled with great care and reproduced in accordance with effective control measures. This documentation may contain errors, and the information it contains and the corresponding technical data are subject to change without notice. Reproduction of any part of this documentation or its processing or revision using electronic systems is prohibited without the manufacturer's prior written approval. Components, devices and measurement sensors made by burster praezisionsmesstechnik (hereinafter referred to as the...
Open the catalog to page 2The measurement solution. EU-Konformitatserklarung (nach en iso/iec 17050-1:2010) EU-Declaration of conformity (in accordance with EN ISO/IEC 17050-1:2010) Name des Ausstellers: Issuer’s name: Anschrift des Ausstellers: Issuer’s address: Gegenstand der Erklarung: Object of the declaration: burster prazisionsmesstechnik gmbh & co kg Talstr. 1-5 76593 Gernsbach, Germany DIGIFORCE®X/Y-Monitoring, Einpress-, Fijge-, Niet- und Verstemmuberwachung DIGIFORCE® X/Y-Monitoring, press-fit Joining, rivet and caulking monitoring DIGIFORCE® 9311 Modellnummer(n) (Typ): Model number /type: Diese Erklarung...
Open the catalog to page 3® The following symbols on the DIGIFORCE 9311 and in this operation manual warn of hazards. 1.1 Symbols used in the instruction manual 1.1.1 Signal words The following signal words are used in the operation manual according to the specified hazard classification. DANGER High degree of risk: indicates a hazardous situation which, if not avoided, will result in death or serious injury. A WARNING Moderate degree of risk: indicates a hazardous situation which, if not avoided, may result in death or serious injury. A CAUTION Low degree of risk: indicates a hazardous situation which, if not...
Open the catalog to page 92 Introduction IMPORTANT: Read the operation manual carefully before using the equipment, and keep for future reference. ® The DIGIFORCE 9311 is an instrument that is designed to monitor repetitive production processes. Its core function is to record and analyse process signals representing physical variables between which there is a defined relationship, for instance recording a curve of force, pressure or torque plotted against displacement, angle or time. Graphical evaluation elements such as windows, trapezoids, thresholds or envelopes are used to analyse the resultant curve. The...
Open the catalog to page 112.4 Ambient conditions 2.4.1 Storage conditions The following requirements must be met when storing the DIGIFORCE 9311: • Store at temperatures between 0 °C and +60 °C • The unit must be packed in clean packaging • Store in a dry environment • No condensation 2.4.2 Operating conditions The following requirements must be met when operating the DIGIFORCE 9311: • Always operate indoors • Maximum height above sea level 2000 m • Operate at temperatures between +5 °C and +40 °C, ideally +23 °C • Humidity: 80% up to +31 °C, decreasing linearly above that temperature to 50% at Tmax, no condensation...
Open the catalog to page 12DANGER Electrical shock hazard Disconnect the DIGIFORCE® 9311 from the power plug before cleaning. ® Disconnect the DIGIFORCE 9311 from the power plug and use a slightly damp cloth for cleaning the unit. NOTICE ® Do not immerse the DIGIFORCE 9311 in water or hold it under running water. Do not use strong cleaning agents as these may damage the instrument. Use a slightly damp cloth to clean the instrument. 2.5 Personnel Personnel must be familiar with the relevant regulations. They must follow these regulations. Only trained personnel who are familiar with the applicable safety regulations...
Open the catalog to page 13DANGER Electrical shock hazard Never switch on the instrument if it shows signs of damage incurred in transit. Only ever use the instrument under the conditions specified in this operation manual. Inspect the instrument for damage. If you suspect that the unit has been damaged during shipping, notify the delivery company within 72 hours. ® The DIGIFORCE 9311 should be shipped only in its original packaging or in packaging capable of providing an equivalent degree of protection. burster praezisionsmesstechnik gmbh & co kg provides a manufacturer's warranty for a period of 24 months after...
Open the catalog to page 142.10 Error messages when the unit is powered up ® During boot-up, the DIGIFORCE 9311 may display certain error messages. The following errors mean that the DIGIFORCE® 9311 must be sent in for checking and possibly repair: For further information, please refer to section 2.2 "Customer Service" on page 11.
Open the catalog to page 153 Principles of design and operation ® Please refer to the DIGIFORCE 9311 data sheet for full details of dimensions, weight, degree of protection etc. 3.1 Range of functions The DIGIFORCE® 9311 monitors processes in which precisely defined functional relationships need to be demonstrated between two measured quantities. These measured quantities are recorded synchronously during the manufacturing process or subsequent functional testing to produce a measurement curve, which is then assessed using graphical evaluation elements. After evaluating the measurements, the instrument displays the...
Open the catalog to page 163.3 Power supply The instrument can be operated with a voltage of 100 to 240 VAC (±10 %) / 50 to 60 Hz (±10 %) / typical 15 VA. A DANGER Inspect the power lead for damage before use. Do not connect the power lead if there are signs of damage. To help identify damage to the power lead in good time, test it regularly in accordance with national accident prevention regulations. 3.4 Sensors suitable for use with the instrument ® The DIGIFORCE 9311 can process signals from a huge range of sensor technologies. Note: The "Channel settings" menu (M21) is where the physical connectors, and hence the...
Open the catalog to page 17All Burster präzisionsmesstechnik gmbh & co kg catalogs and technical brochures
-
SENSOR SOLUTIONS
1 Pages
-
A CONNECTION THAT NETWORKS
1 Pages
-
Quality leading the way
3 Pages
-
Data-Sheet - 9251
6 Pages
-
Data Sheet Model 9210
5 Pages
-
Flyer Load Experts
1 Pages
-
Load cells
25 Pages
-
Data Sheet 8427
7 Pages
-
Displacement Sensors
2 Pages
-
Displacement Sensors
2 Pages
-
Data Sheet Typ 87240
2 Pages
-
Data sheet Typ 8416
6 Pages
-
Load cells
25 Pages
-
Data Sheet Model 8402
6 Pages
-
Flyer Load Experts
1 Pages
-
Data Sheet - Model 8438
6 Pages
-
Data Sheet Model 8400-B001
2 Pages
-
Sensor Solutions
1 Pages
-
A Connection that Networks
1 Pages
-
Qualitiy leading the way
3 Pages
-
Data Sheet Model 9250
7 Pages
-
Torque Sensors
9 Pages
-
Data Sheet Typ 8656
7 Pages
-
Data Sheet Model 9235
2 Pages
-
Data sheet Model 8435
7 Pages
-
Data Sheet Typ 8417
7 Pages
-
Data Sheet Typ 8532
2 Pages
-
Torque Sensors
9 Pages
-
Data Sheet Typ 8627
2 Pages
-
Data Sheet Model 8527
7 Pages
-
Data Sheet Model 8526
9 Pages
-
Data Sheet Typ 8655
7 Pages
-
Data Sheet Model 8431
12 Pages
-
Pressfitting -the reliable way
11 Pages
-
Data Sheet Typ 9311
6 Pages
-
Data Sheet Model 8511
6 Pages
-
Data Sheet - DIGISTANT® 4463
5 Pages
-
Data sheet Series 8738
2 Pages
-
Torque Sensors
16 Pages
-
Data Sheet Model 8630
6 Pages
-
Data Sheet Typ 8625
7 Pages
-
Data Sheet Models 8710, 8711
2 Pages
-
Data Sheet Typ 8740/8741
4 Pages
-
Data Sheet Models 8712, 8713
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8451
7 Pages
-
Procision to the core
3 Pages
-
Flyer Battery Tester
1 Pages
-
Data Sheet Model 2560
5 Pages
-
Data Sheet Model 8561
6 Pages
-
Data Sheet Model 2311
5 Pages
-
Data Sheet Model 8523
8 Pages
-
Data Sheet Series 87350
2 Pages
-
Data Sheet Model 9243
2 Pages
-
Operation manual
76 Pages
-
Data Sheet Typ 8739
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8565
5 Pages
-
Data sheet Model 8631
5 Pages
-
Data Sheet Model 8718
2 Pages
-
Data Sheet Typ 8512
5 Pages
-
Data-Sheet- Model 8228
6 Pages
-
Data Sheet Model 8510
5 Pages
-
Data Sheet Model 8415
6 Pages
-
Data Sheet Model 2511
6 Pages
-
RESISTOMAT® Model 2329
4 Pages
-
Data Sheet Model 8524
8 Pages
-
Data Sheet Model 2550
4 Pages
-
Data Sheet Model 9186/8532
2 Pages
-
Data Sheet Typ 8645
5 Pages
-
Data sheet Model 8709
2 Pages
-
Flyer Displacement Sensor
2 Pages
-
Data Sheet - Model 8670
4 Pages