Catalog excerpts
OPERATING MANUAL DIGIFORCE® model 9307 © 2018 burster praezisionsmesstechnik gmbh & co kg All rights reserved Valid from: 20.02.2019 Manufacturer: burster praezisionsmesstechnik gmbh & co kg Talstr. 1 - 5 P.O. Box 1432 Germany Germany Email: info@burster.com
Open the catalog to page 1Warranty disclaimer All information in the present documentation was prepared and compiled with great care and reproduced in accordance with effective control measures. This documentation may contain errors, and the information it contains and the corresponding technical data are subject to change without notice. Reproduction of any part of this documentation or its processing or revision using electronic systems is prohibited without the manufacturer's prior written approval. Components, devices and measurement sensors made by burster praezisionsmesstechnik (hereinafter referred to as the...
Open the catalog to page 2The measurement solution. EU-Konformitatserklarung (nach en iso/iec 17050-1:2010) EU-Declaration of conformity (in accordance with EN ISO/IEC 17050-1:2010) Name des Ausstellers: Issuer's name: burster prazisionsmesstechnik gmbh & co kg Anschrift des Ausstellers: Issuer’s address: Gegenstand der Erklarung: Object of the declaration: Talstr. 1-5 76593 Gernsbach, Germany Universeller Prozess-Cortroller DIGIFORCE® Universal Process-Controller DIGIFORCE® Modellnummer(n) (Typ): Model number /type: Diese Erklarung beinhaltet obengenannte Produkte mit alien Optioner This declaration covers all...
Open the catalog to page 34.4.4.1 Connector C: Connection guidance for incremental sensors ...49
Open the catalog to page 66.8.1.3 Additional results when recording two curves Y1(x) and Y2(x)123 6.8.2.2 Additional results when recording two curves Y1(x) and Y2(x)130
Open the catalog to page 86.12.1 Parameters in „Sensor test" for channel X, Y1 und Y2 menu (menu 36)170 9.1.1 Changing the measurement program without program acknowledgement198 9.1.2 Changing the measurement program with program acknowledgement199
Open the catalog to page 99.4.2.1 Switching signals for channel “X“ with ABSOLUTE reference205 9.4.2.2 Switching signals for channel “X“ with TRIGGER reference ..206
Open the catalog to page 10DIGIFORCE® 93071 For your safety ® The following symbols on the DIGIFORCE 9307 and in this operating manual warn of hazards. 1.1 Symbols used in this manual 1.1.1 Signal words The following signal words are used in the operating manual according to the specified hazard classification. DANGER High degree of risk: indicates a hazardous situation which, if not avoided, will result in death or serious injury. A WARNING Moderate degree of risk: indicates a hazardous situation which, if not avoided, may result in death or serious injury. A CAUTION Low degree of risk: indicates a hazardous...
Open the catalog to page 11DIGIFORCE® 93071.2 Symbols and precautionary statements on the DIGIFORCE® 9307 Symbol
Open the catalog to page 12DIGIFORCE® 93072 Introduction IMPORTANT: Read the operating manual carefully before using the equipment, and keep for future reference. The DIGIFORCE® 9307 is an instrument for monitoring repetitive production processes. Its core function is to record and analyze signals from processes in which physical variables, such as force, pressure or torque, vary as a function of displacement, angle or time according to a defined curve. The resultant measurement curve is analyzed using graphical evaluation elements such as windows, envelopes and thresholds. The result of the analysis is classified as...
Open the catalog to page 13DIGIFORCE® 93072.4 Ambient conditions 2.4.1 Storage conditions The following requirements must be met when storing the DIGIFORCE 9307: • The DIGIFORCE 9307 must be packed in clean packaging • Store in dry environment • No condensation • Store at temperatures between 0° C and +60° C 2.4.2 Operating conditions The following requirements must be met when operating the DIGIFORCE 9307: • Always operate indoors • Maximum height: above sea level 2000 m • Operate at temperatures between: +5 °C ... +40 °C, ideally +23 °C • Humidity: 80% up to +31 °C, decreasing flinearly above that temperature to...
Open the catalog to page 14DANGER Electrical shock hazard Disconnect the DIGIFORCE® 9307 from the power plug before cleaning. ® Disconnect the DIGIFORCE 9307 from the power plug and use a slightly damp cloth for cleaning the unit. NOTICE Do not immerse the DIGIFORCE 9307 in water or hold it under running water. Do not use strong cleaning agents as these may damage the DIGIFORCE® 9307. Use a slightly damp cloth to clean the DIGIFORCE® 9307. Personnel must be familiar with the relevant regulations. They must follow these regulations. Only trained personnel who are familiar with the applicable safety regulations are...
Open the catalog to page 15DANGER Electrical shock hazard ® Never switch on the DIGIFORCE 9307 if it shows signs of damage incurred in ® transit. Only ever use the DIGIFORCE 9307 under the conditions specified in this operating manual. ® Inspect the DIGIFORCE 9307 for damage. If you suspect that the unit has been damaged during shipping, notify the delivery company within 72 hours. ® The DIGIFORCE 9307 should be shipped only in its original packaging or in packaging capable of providing an equivalent degree of protection. burster praezisionsmesstechnik gmbh & co kg provides a manufacturer's warranty for a period of...
Open the catalog to page 16DIGIFORCE® 9307 2.10 Error messages when the unit is powered up During boot-up, the DIGIFORCE® 9307 may display certain error messages. The following errors mean that the DIGIFORCE® 9307 must be sent in for checking and possibly repair: For further information, please refer to section 2.2 "Customer service" on page 13.
Open the catalog to page 17Principles of design and operation ® Please refer to the DIGIFORCE 9307 data sheet for technical data, full details of dimensions, weight, degree of protection etc. The DIGIFORCE 9307 monitors processes in which precisely defined functional relationships between two or more measured quantities need to be demonstrated. These measured quantities are recorded synchronously during the manufacturing process or subsequent functional testing to produce a measurement curve, which is then assessed using graphical and mathematical evaluation techniques. After internal evaluation, the measurement...
Open the catalog to page 18All Burster präzisionsmesstechnik gmbh & co kg catalogs and technical brochures
-
SENSOR SOLUTIONS
1 Pages
-
A CONNECTION THAT NETWORKS
1 Pages
-
Quality leading the way
3 Pages
-
Data-Sheet - 9251
6 Pages
-
Data Sheet Model 9210
5 Pages
-
Flyer Load Experts
1 Pages
-
Load cells
25 Pages
-
Data Sheet 8427
7 Pages
-
Displacement Sensors
2 Pages
-
Displacement Sensors
2 Pages
-
Data Sheet Typ 87240
2 Pages
-
Data sheet Typ 8416
6 Pages
-
Load cells
25 Pages
-
Data Sheet Model 8402
6 Pages
-
Flyer Load Experts
1 Pages
-
Data Sheet - Model 8438
6 Pages
-
Data Sheet Model 8400-B001
2 Pages
-
Sensor Solutions
1 Pages
-
A Connection that Networks
1 Pages
-
Qualitiy leading the way
3 Pages
-
Data Sheet Model 9250
7 Pages
-
Torque Sensors
9 Pages
-
Data Sheet Typ 8656
7 Pages
-
Data Sheet Model 9235
2 Pages
-
Data sheet Model 8435
7 Pages
-
Data Sheet Typ 8417
7 Pages
-
Data Sheet Typ 8532
2 Pages
-
Torque Sensors
9 Pages
-
Data Sheet Typ 8627
2 Pages
-
Data Sheet Model 8527
7 Pages
-
Data Sheet Model 8526
9 Pages
-
Data Sheet Typ 8655
7 Pages
-
Data Sheet Model 8431
12 Pages
-
Pressfitting -the reliable way
11 Pages
-
Data Sheet Typ 9311
6 Pages
-
Data Sheet Model 8511
6 Pages
-
Data Sheet - DIGISTANT® 4463
5 Pages
-
Data sheet Series 8738
2 Pages
-
Torque Sensors
16 Pages
-
Data Sheet Model 8630
6 Pages
-
Data Sheet Typ 8625
7 Pages
-
Data Sheet Models 8710, 8711
2 Pages
-
Data Sheet Typ 8740/8741
4 Pages
-
Data Sheet Models 8712, 8713
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8451
7 Pages
-
Procision to the core
3 Pages
-
Flyer Battery Tester
1 Pages
-
Data Sheet Model 2560
5 Pages
-
Data Sheet Model 8561
6 Pages
-
Data Sheet Model 2311
5 Pages
-
Data Sheet Model 8523
8 Pages
-
Data Sheet Series 87350
2 Pages
-
Data Sheet Model 9243
2 Pages
-
Operation manual
76 Pages
-
Data Sheet Typ 8739
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8565
5 Pages
-
Data sheet Model 8631
5 Pages
-
Data Sheet Model 8718
2 Pages
-
Data Sheet Typ 8512
5 Pages
-
Data-Sheet- Model 8228
6 Pages
-
Data Sheet Model 8510
5 Pages
-
Data Sheet Model 8415
6 Pages
-
Data Sheet Model 2511
6 Pages
-
RESISTOMAT® Model 2329
4 Pages
-
Data Sheet Model 8524
8 Pages
-
Data Sheet Model 2550
4 Pages
-
Data Sheet Model 9186/8532
2 Pages
-
Data Sheet Typ 8645
5 Pages
-
Data sheet Model 8709
2 Pages
-
Flyer Displacement Sensor
2 Pages
-
Data Sheet - Model 8670
4 Pages