Catalog excerpts
![OPERATING MANUAL 2-Axis Load Cell XY Model 8561 - 1](https://img.directindustry.com/pdf/repository_di/13615/operating-manual-2-axis-load-cell-xy-model-8561-1066554_1m.jpg)
OPERATING MANUAL 2-Axis Load Cell XY Model 8561 © 2021 Manufacturer: burster burster prazisionsmesstechnik gmbh & co kg prazisionsmesstechnik gmbh & co kg All rights reserved Talstr. 1-5 Postfach 1432 Germany Germany Valid from: February 05, 2021
Open the catalog to page 1![OPERATING MANUAL 2-Axis Load Cell XY Model 8561 - 2](https://img.directindustry.com/pdf/repository_di/13615/operating-manual-2-axis-load-cell-xy-model-8561-1066554_2m.jpg)
Warranty disclaimer All information in the present documentation was prepared and compiled with great care and reproduced in accordance with effective control measures. No warranty is provided for freedom from errors. We reserve the right to make technical changes. The present information as well as the corresponding technical data can change without notice. Reproduction of any part of this documentation or its processing or revision using electronic systems is prohibited without the manufacturer’s prior written approval. Components, devices and measurement sensors made by burster...
Open the catalog to page 2![OPERATING MANUAL 2-Axis Load Cell XY Model 8561 - 3](https://img.directindustry.com/pdf/repository_di/13615/operating-manual-2-axis-load-cell-xy-model-8561-1066554_3m.jpg)
2-Axis Load Cell XY Model 8561The measurement solution. EU-Konformitatserklarung (nach en iso/i ec 17050-1:2010) EU-Declaration of conformity (in accordance with EN ISO/IEC 17050-1:2010) Name des Ausstellers: Issuer's name: Anschrift des Ausstellers: Issuer's address: Gegenstand der Erklarung: Object of the declaration: burster prazisionsmesstechnik gmbh & co kg Talstr. 1-5 76593 Gernsbach, Germany Kraflsensor Load Cell Modellnummer(n) (Typ): 84xx; 85xx Diese Erklarung beinhaltet obengenannte Produkte mit alien Optionen This declaration covers all options of the above product(s) Das oben...
Open the catalog to page 3![OPERATING MANUAL 2-Axis Load Cell XY Model 8561 - 6](https://img.directindustry.com/pdf/repository_di/13615/operating-manual-2-axis-load-cell-xy-model-8561-1066554_6m.jpg)
2-Axis Load Cell XY Model 8561 1 For your safety The following symbols are used in this operation manual to warn of hazards. 1.1 Symbols used in the operating manual 1.1.1 Signal words The following signal words are used in the operating manual according to the specified hazard classification. High degree of risk: indicates a hazardous situation which, if not avoided, will result in death or serious injury. A warning Moderate degree of risk: indicates a hazardous situation which, if not avoided, may result in death or serious injury. A caution Low degree of risk: indicates a hazardous...
Open the catalog to page 6![OPERATING MANUAL 2-Axis Load Cell XY Model 8561 - 7](https://img.directindustry.com/pdf/repository_di/13615/operating-manual-2-axis-load-cell-xy-model-8561-1066554_7m.jpg)
2-Axis Load Cell XY Model 8561 2 introduction IMPORTANT: Read the operating manual carefully before using the equipment, and keep for future reference. The load cells in the 8561 model series are primarily designed for the measurement of force in production equipment, using newtons (N) as the unit of measurement. The local gravitational acceleration (g = 9.81 m/s2) must be taken into account when determining masses. 2.1.1 Customer service department For repair inquiries, please call our customer service department on +49 7224 645-53. Please have the serial number to hand. The serial number...
Open the catalog to page 7![OPERATING MANUAL 2-Axis Load Cell XY Model 8561 - 8](https://img.directindustry.com/pdf/repository_di/13615/operating-manual-2-axis-load-cell-xy-model-8561-1066554_8m.jpg)
2-Axis Load Cell XY Model 8561 2.3.1 Storage The model 8561 2-axis load cell must be stored under the following conditions: • dry • no condensation • temperature between 0 °C and 60 °C Note: Provided the storage conditions have been observed, no special steps need to be taken after storage and prior to commissioning. notice Only connect the model 8561 2-axis load cell to instrumentation amplifiers that are fitted with a safety transformer to EN 61558. Transmitters connected to the outputs or other devices that are galvanically connected to the sensor’s signal lines must also be fitted with...
Open the catalog to page 8![OPERATING MANUAL 2-Axis Load Cell XY Model 8561 - 9](https://img.directindustry.com/pdf/repository_di/13615/operating-manual-2-axis-load-cell-xy-model-8561-1066554_9m.jpg)
2-Axis Load Cell XY Model 8561 2.4 Personnel Personnel must be familiar with the relevant regulations. They must follow these regulations. Only trained personnel who are familiar with the applicable safety regulations are permitted to operate the model 8561 2-axis load cell. 2.5 Contents of pack • 2-axis load cell, model 8561 • Connector socket 90° angle (9900-V647) • Test certificate Inspect the model 8561 2-axis load cell for damage. If you suspect that the unit has been damaged during shipping, notify the delivery company within 72 hours. The packaging should be retained by a...
Open the catalog to page 9![OPERATING MANUAL 2-Axis Load Cell XY Model 8561 - 10](https://img.directindustry.com/pdf/repository_di/13615/operating-manual-2-axis-load-cell-xy-model-8561-1066554_10m.jpg)
The warranty shall be deemed void immediately if you open or dismantle the model 8561 2axis load cell during the warranty period. The model 8561 2-axis load cell does not contain any parts that are intended to be serviced by the user. Only the manufacturer’s own qualified personnel are permitted to open the model 8561 2-axis load cell. It is not permitted to make any changes to the model 8561 2-axis load cell without the written agreement of burster präzisionsmesstechnik gmbh & co kg. burster präzisionsmesstechnik gmbh & co kg does not accept liability for damages or injury if this...
Open the catalog to page 10![OPERATING MANUAL 2-Axis Load Cell XY Model 8561 - 11](https://img.directindustry.com/pdf/repository_di/13615/operating-manual-2-axis-load-cell-xy-model-8561-1066554_11m.jpg)
Concept and general information Please refer to the data sheet for the model 8561 2-axis load cell for full details of dimensions, weight, degree of protection etc. Mechanical design The model 8561 2-axis load cell consists of two spring elements in the form of bending beams, which are joined to the central part. Strain gages X/Y measuring elements with strain gages applied A radial force in the central part of the load cell deforms these measuring elements, causing a displacement of the measuring axis. The resulting elongation is not visible to the naked eye and is measured using strain...
Open the catalog to page 11![OPERATING MANUAL 2-Axis Load Cell XY Model 8561 - 12](https://img.directindustry.com/pdf/repository_di/13615/operating-manual-2-axis-load-cell-xy-model-8561-1066554_12m.jpg)
2-Axis Load Cell XY Model 8561 U * Figure 2: Foil strain gage Special techniques are used to mount strain gages manufactured in this way onto the surface of the spring element. 3.2.2.1 Strain gage wiring In order to reduce undesirable influences on the measurement, in the model 8561 2-axis load cell four strain gages are connected as a Wheatstone bridge for each measurement direction. Figure 3 illustrates this wiring in a simplified form. Figure 3: Full-bridge strain gage on the model 8561 2-axis load cell for one measurement direction To reduce the effect of temperature,...
Open the catalog to page 12![OPERATING MANUAL 2-Axis Load Cell XY Model 8561 - 13](https://img.directindustry.com/pdf/repository_di/13615/operating-manual-2-axis-load-cell-xy-model-8561-1066554_13m.jpg)
External forces External forces here refers to any force that does not act radially to the sensor’s axis of symmetry – particularly transverse forces, bending moments and torsional forces. NOTICE Damage to the model 8561 2-axis load cell Avoid vibrations, even if the generated loads remain below the rated load and avoid external forces acting on the load cell. Design your measuring system in such a way as to prevent these external forces. IMPORTANT: External forces acting on the model 8561 2-axis load cell will significantly falsify the measurement result!
Open the catalog to page 13All Burster präzisionsmesstechnik gmbh & co kg catalogs and technical brochures
-
Press fitting - the reliable way
11 Pages
-
Data Sheet Typ 9307
6 Pages
-
Data Sheet Model 2511
6 Pages
-
Data Sheet Typ 8625
7 Pages
-
Data Sheet Model 9243
2 Pages
-
Data Sheet- Model 2500
2 Pages
-
SENSOR SOLUTIONS
1 Pages
-
A CONNECTION THAT NETWORKS
1 Pages
-
Quality leading the way
3 Pages
-
Data-Sheet - 9251
6 Pages
-
Data Sheet Model 9210
5 Pages
-
Flyer Load Experts
1 Pages
-
Data Sheet 8427
7 Pages
-
Displacement Sensors
2 Pages
-
Displacement Sensors
2 Pages
-
Data Sheet Typ 87240
2 Pages
-
Data sheet Typ 8416
6 Pages
-
Load cells
25 Pages
-
Data Sheet Model 8402
6 Pages
-
Flyer Load Experts
1 Pages
-
Data Sheet - Model 8438
6 Pages
-
Data Sheet Model 8400-B001
2 Pages
-
Sensor Solutions
1 Pages
-
A Connection that Networks
1 Pages
-
Qualitiy leading the way
3 Pages
-
Data Sheet Model 9250
7 Pages
-
Data Sheet Typ 8656
7 Pages
-
Data Sheet Model 9235
2 Pages
-
Data sheet Model 8435
7 Pages
-
Data Sheet Typ 8417
7 Pages
-
Data Sheet Typ 8532
2 Pages
-
Torque Sensors
9 Pages
-
Data Sheet Typ 8627
2 Pages
-
Data Sheet Model 8527
7 Pages
-
Data Sheet Model 8526
9 Pages
-
Data Sheet Model 8431
12 Pages
-
Data Sheet Typ 9311
6 Pages
-
Data Sheet Model 8511
6 Pages
-
Data Sheet - DIGISTANT® 4463
5 Pages
-
Data sheet Series 8738
2 Pages
-
Torque Sensors
16 Pages
-
Data Sheet Model 8630
6 Pages
-
Data Sheet Models 8710, 8711
2 Pages
-
Data Sheet Typ 8740/8741
4 Pages
-
Data Sheet Models 8712, 8713
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8451
7 Pages
-
Procision to the core
3 Pages
-
Flyer Battery Tester
1 Pages
-
Data Sheet Model 2560
5 Pages
-
Data Sheet Model 8561
6 Pages
-
Data Sheet Model 2311
5 Pages
-
Data Sheet Model 8523
8 Pages
-
Data Sheet Series 87350
2 Pages
-
Operation manual
76 Pages
-
Data Sheet Typ 8739
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8565
5 Pages
-
Data sheet Model 8631
5 Pages
-
Data Sheet Model 8718
2 Pages
-
Data Sheet Typ 8512
5 Pages
-
Data-Sheet- Model 8228
6 Pages
-
Data Sheet Model 8510
5 Pages
-
Data Sheet Model 8415
6 Pages
-
RESISTOMAT® Model 2329
4 Pages
-
Data Sheet Model 8524
8 Pages
-
Data Sheet Model 2550
4 Pages
-
Data Sheet Model 9186/8532
2 Pages
-
Data Sheet Typ 8645
5 Pages
-
Data sheet Model 8709
2 Pages
-
Flyer Displacement Sensor
2 Pages
-
Data Sheet - Model 8670
4 Pages