Catalog excerpts
![Data sheet USB Sensor Interface Model 9206 - 1](https://img.directindustry.com/pdf/repository_di/13615/data-sheet-usb-sensor-interface-model-9206-1064545_1m.jpg)
USB Sensor Interface For strain gauge, potentiometric, DC/DC and Pt100 sensors Model 9206 Application In the field there is a frequent need to measure sensor readings rapidly and easily right at the sensor and to transfer them directly to a PC without additional amplifiers or converters. The 9206 USB sensor interface can satisfy this requirement admirably, thanks to its „plug & measure" design. The USB connection means installation could not be simpler. Typical applications: ► Mobile test measurements via laptop ► Laboratory test set-ups ► Instrumentation and control ► Diagnostic measurements in the chemical industry ► PC-based recording of expansion figures in bio engineering Technical changes reserved. All data sheets at www.burster.com ■ Inexpensive "Plug & Measure" design ■ Simple connection via PC USB port ■ Measurement accuracy < 0.05 % F.S., optional 0.01 % F.S. incl. DAkkS ■ 24 bit resolution ■ 6 wire technology for the highest precision ■ High-speed measurement of up to 1200 readings/sec. ■ Convenient configuration and analysis software DigiVision for max. 32 measurement channels ■ Pt100 as option ■ LabVIEW, DASYLab and DLL drivers free of charge Description “Plug & Measure” is the concept of the USB sensor interface 9206. Whether as a 1 channel In-Line version or as a multi-channel solution in a desktop housing, the 9206 provides high-performance and cost-effective measured value acquisition for analog sensors such as full-bridge strain gages and potentiometric sensors , DC/DC transmitter and Pt100 sensor. With the DigiVision measurement software included in the scope of delivery, the USB sensor interface can be flexibly parameterized for your measurement task. The software offers extensive functions for recording, displaying and logging measurement data. With the LabVIEW and DLL driver packages available free of charge, the USB sensor interface can be flexibly integrated into your own programs. Whether in the laboratory as a table-top device or in a harsh environment as a 1 channel InLine IP67 version, the USB sensor interface can be used in many ways. The 9206 in a desktop case with an increased measuring accuracy of 0.01 % F.S. is suitable for precision applications with DAkkS certificate. burster praezisionsmesstechnik gmbh & co kg Germany www.burster.com Talstr. 1-5 ■ Gernsbach 76593 ■ Phone +49-7224-6450 info@burster.com
Open the catalog to page 1![Data sheet USB Sensor Interface Model 9206 - 2](https://img.directindustry.com/pdf/repository_di/13615/data-sheet-usb-sensor-interface-model-9206-1064545_2m.jpg)
Technical Data Connectable sensors Strain gauge Bridge resistance: Connection system: Sensitivity: Sensor excitation: Excitation current: Measurement: Potentiometer Connection system: Resistance: Measurement signal: Sensor excitation: Excitation current: Measurement error: Software DigiVision System requirement: Order Code USB-Sensor-Interface 9206-V IP67 - In-Line IP40 - In-Line with 12 pin connector for sensors Strain gauge, Poti, DC/DC Pt100 including measurement and analysis software 9206-P001 USB multi sensor interface - in housing Transmitter and DC/DC sensors Sensor excitation:...
Open the catalog to page 2![Data sheet USB Sensor Interface Model 9206 - 3](https://img.directindustry.com/pdf/repository_di/13615/data-sheet-usb-sensor-interface-model-9206-1064545_3m.jpg)
DigiVision Configuration and Analysis Software General Software Data ► Functions like tare and reset ► Convenient device finder ► Export function to Excel ► Instrument parameterization ► Instrument data adopted automatically, min/max values switchable in measuring mode ► Communication with a controller unit e.g. scaling, limit settings ► Back-up function for instrument data ► Simultaneous display of up to 16 measurement channels ► Different measurement rates can be combined ► Different triggers can be set: global or channel-specific ► Creation of instrument groups ► Report finder for...
Open the catalog to page 3![Data sheet USB Sensor Interface Model 9206 - 4](https://img.directindustry.com/pdf/repository_di/13615/data-sheet-usb-sensor-interface-model-9206-1064545_4m.jpg)
Software DigiVision 9206-P200 ► Intuitive operation ► Easy-going configuration the interfaces ► Measurement rate up to 1200 meas./sec. for every channel ► Up to 32 measurements at the same time ► Storage of measurement protocols ► Data export in Excel ► Free mathematical measuring channels Typical Applications ► Differential measurements ► Averaging of the measurement results ► Determination of efficiency in engine test Technical changes reserved. All data sheets at www.burster.com ► Determine mass moment of inertia ► Determine the frictional force ► Comparison of different measurement...
Open the catalog to page 4All Burster präzisionsmesstechnik gmbh & co kg catalogs and technical brochures
-
Press fitting - the reliable way
11 Pages
-
Data Sheet Typ 9307
6 Pages
-
Data Sheet Model 2511
6 Pages
-
Data Sheet Typ 8625
7 Pages
-
Data Sheet Model 9243
2 Pages
-
Data Sheet- Model 2500
2 Pages
-
SENSOR SOLUTIONS
1 Pages
-
A CONNECTION THAT NETWORKS
1 Pages
-
Quality leading the way
3 Pages
-
Data-Sheet - 9251
6 Pages
-
Data Sheet Model 9210
5 Pages
-
Flyer Load Experts
1 Pages
-
Data Sheet 8427
7 Pages
-
Displacement Sensors
2 Pages
-
Displacement Sensors
2 Pages
-
Data Sheet Typ 87240
2 Pages
-
Data sheet Typ 8416
6 Pages
-
Load cells
25 Pages
-
Data Sheet Model 8402
6 Pages
-
Flyer Load Experts
1 Pages
-
Data Sheet - Model 8438
6 Pages
-
Data Sheet Model 8400-B001
2 Pages
-
Sensor Solutions
1 Pages
-
A Connection that Networks
1 Pages
-
Qualitiy leading the way
3 Pages
-
Data Sheet Model 9250
7 Pages
-
Data Sheet Typ 8656
7 Pages
-
Data Sheet Model 9235
2 Pages
-
Data sheet Model 8435
7 Pages
-
Data Sheet Typ 8417
7 Pages
-
Data Sheet Typ 8532
2 Pages
-
Torque Sensors
9 Pages
-
Data Sheet Typ 8627
2 Pages
-
Data Sheet Model 8527
7 Pages
-
Data Sheet Model 8526
9 Pages
-
Data Sheet Model 8431
12 Pages
-
Data Sheet Typ 9311
6 Pages
-
Data Sheet Model 8511
6 Pages
-
Data Sheet - DIGISTANT® 4463
5 Pages
-
Data sheet Series 8738
2 Pages
-
Torque Sensors
16 Pages
-
Data Sheet Model 8630
6 Pages
-
Data Sheet Models 8710, 8711
2 Pages
-
Data Sheet Typ 8740/8741
4 Pages
-
Data Sheet Models 8712, 8713
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8451
7 Pages
-
Procision to the core
3 Pages
-
Flyer Battery Tester
1 Pages
-
Data Sheet Model 2560
5 Pages
-
Data Sheet Model 8561
6 Pages
-
Data Sheet Model 2311
5 Pages
-
Data Sheet Model 8523
8 Pages
-
Data Sheet Series 87350
2 Pages
-
Operation manual
76 Pages
-
Data Sheet Typ 8739
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8565
5 Pages
-
Data sheet Model 8631
5 Pages
-
Data Sheet Model 8718
2 Pages
-
Data Sheet Typ 8512
5 Pages
-
Data-Sheet- Model 8228
6 Pages
-
Data Sheet Model 8510
5 Pages
-
Data Sheet Model 8415
6 Pages
-
RESISTOMAT® Model 2329
4 Pages
-
Data Sheet Model 8524
8 Pages
-
Data Sheet Model 2550
4 Pages
-
Data Sheet Model 9186/8532
2 Pages
-
Data Sheet Typ 8645
5 Pages
-
Data sheet Model 8709
2 Pages
-
Flyer Displacement Sensor
2 Pages
-
Data Sheet - Model 8670
4 Pages