Data Sheet Typ 8532-1

Low-Cost Compressive Load Cell With IN-LINE amplifier Very economical price Application This force measurement chain was developed for applications where a low cost solution is more important than achieving high levels of accuracy. The sensors strain gauge technology allows the measurement of static and dynamic forces. The load cell is also designed for applications that provide only little space due to its compact design. These properties, together with the sensors dust protection, make the measuring chain suitable for a wide range of applications, such as ►► ►► ►► ►► ►► ►► Industrial manufacture Manufacture of customized machinery Geological investigations Motor vehicle engineering Commercial agriculture Bridge building Technical changes reserved. All data sheets at www.burster.com Measuring ranges between 0 ... 500 N and 0 ... 20 kN Normalized output signal 0 ... 10 V Stainless steel sensor Compact design Customer-specific versions possible from 20 pieces up Description The body of the sensor is a flat, cylindrical disk, into which a domed force application knob is integrated. It is important that the force is applied axially to the center of the sensor. The domed form, however, minimizes the effect of a force that is not exactly axial. A full-bridge strain gauge is used as the measuring element inside the sensor, by means of which the force to be measured is converted into a proportional electrical voltage. The in-line amplifier increases this voltage from 0 up to 10 V. The surface against which the sensor rests is important for the quality of the measurement. It should be ground. It must be sufficiently hard and thick and not deform under load. burster praezisionsmesstechnik gmbh & co kg Germany Talstr. 1-5 . Gernsbach 76593 . Phone +49-7224-6450 www.burster.com [email protected]

 Open the catalog to page 1
Data Sheet Typ 8532-2

Technical Data Order Code Measuring Range Electrical values Dimensional drawing 15 ... 30 V DC 0 ... 10 V 440 Ω, nominal 1 kHz > 2000 MΩ 350 Ω, nominal max. 0.3 VA Environmental conditions Sensor Range of operation temperature: Range of nominal temperature: Influence of temperature to zero signal: Influence of temperature to measurement signal: Excitation voltage: Output voltage: Output resistance: Limit frequency: Isolation resistance (sensor): Bridge resistance (sensor): Power consumption: Cable outlet refer to the picture at the front side IN-LINE amplifier Ambient temperature: Temperature...

 Open the catalog to page 2

All Burster präzisionsmesstechnik gmbh & co kg catalogs and technical brochures

  1. Load cells

    25  Pages

  2. Load-cell

    25  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.