Delivery: ex stock | Warranty: 24 months Pressure Transmitter ■ Built-in instrumentation amplifier with output 0 ... 10 V ■ Process connection thread G 1/4 inch ■ Vaccum measuring ranges -1 ... +1 bar to -1 ... +10 bar ■ Absolute measurement type ■ Process connection thread G 1/2 inch ■ Flush diaphragm in G 1/4 inch or M10 x 1 ■ Controlling and monitoring of production facilities ■ Monitoring of hydraulic systems ■ Cooling and air-conditioning systems Product description With its rugged housing and a stainless steel sensor element, the transducer is particularly robust and ideally suited to the harshest environments. This also means that the sensor can be installed anywhere with no effect on the measurement signal. The built-in instrumentation amplifier converts the sensor signals into noise-immune voltage signals or current signals that can be transmitted over relatively long distances. For high viscose materials, a front-level membrane M12 x 1 is available, and with this disruptive dead volumes can be expelled. The sensor has a small protected hole on the rear to allow measurement of atmospheric pressure (measurement type relative). For the absolute measurement option, the applied pressure is measured with respect to an enclosed vacuum. As an electrical connection, a DIN 43650A valve connector or an M12 x 1,4-pin connection is available. burster Sensors and Process Instruments - Technical changes reserved. All data sheets at www.burster.com
Open the catalog to page 1Measurement accuracy (Combined ^roreon^tmg of < ±0.25 % F.S. relative, < ±0,5 % F.S. absolute Dead volume at restored diaphragm Temperature effect on zero signal Temperature effect on characteristic value Electrical values Excitation voltage Excitation voltage Voltage output 5 V, Current consumption Voltage output Current consumption Current output Cut-off frequency Reaction time Load resistance Insulation resistance Environmental conditions Rated temperature range Operating temperature Mechanical values Overpressure limit Burst pressure Size Dynamic performance Mechanical shock 100 g/1 ms according...
Open the catalog to page 2Measurement accuracy (Combined error consisting of non-linearity, hysteresis and non-repeatability): burster Sensors and Process Instruments - Technical changes reserved. All data sheets at www.burster.com
Open the catalog to page 3Dimensional drawing – Process connection G 1/4, G 1/2 internal diaphragm Dimensional drawing – Process connection G 1/4, M10 x 1 front flush diaphragm Size A: L 82 mm, Ø D 22 mm; Size B: L 72 mm, Ø D 26.5 mm Size in connection with option absolute messend (-V2xxx) always A Size in connection with option -1 bar (-V3xxx) always B Size in connection with option front flush (-Vxxx1) always B Electrical connections burster Sensors and Process Instruments – Technical changes reserved. All data sheets at www.burster.com For detailed dimensions, you can find the CAD data of the sensor on our website...
Open the catalog to page 4Electrical connections burster Sensors and Process Instruments - Technical changes reserved. All data sheets at www.burster.com
Open the catalog to page 5burster Sensors and Process Instruments - Technical changes reserved. All data sheets at www.burster.com
Open the catalog to page 65 Pages
7 Pages
76 Pages
8 Pages
6 Pages
7 Pages
25 Pages
5 Pages
6 Pages
5 Pages
6 Pages
5 Pages
5 Pages
2 Pages
2 Pages
6 Pages
2 Pages
25 Pages
5 Pages
9 Pages
7 Pages
5 Pages
6 Pages
6 Pages
7 Pages
7 Pages
2 Pages
7 Pages
7 Pages
7 Pages
9 Pages
1 Page
6 Pages
6 Pages
14 Pages
2 Pages
6 Pages
5 Pages
6 Pages
7 Pages
2 Pages
2 Pages
2 Pages
7 Pages
8 Pages
7 Pages
2 Pages
2 Pages
7 Pages
5 Pages
6 Pages
7 Pages
5 Pages
2 Pages
6 Pages
5 Pages
8 Pages
9 Pages
7 Pages
6 Pages
7 Pages
7 Pages
6 Pages
6 Pages
11 Pages
2 Pages
2 Pages
1 Page
1 Page
2 Pages
2 Pages
1 Page
5 Pages
76 Pages
2 Pages
4 Pages
4 Pages
5 Pages
2 Pages
4 Pages
6 Pages