Data Sheet-Pressure Transducer Model 8103-1

■ Measuring ranges between 0 ... 5 bar and 0 ... 1000 bar ■ Accuracy < 0.5 % ■ Flush mounted diaphragm ■ Made of titanium ■ Not magnetic This transducer can be used anywhere thanks to its small size. Designed to work without a measuring chamber (uses a flush front diaphragm instead), this transducer is ideal for any measurements where the material to be measured may leave problematic residues. The range of suitable applications is even greater thanks to a choice of screw-on or weld-on adapters. ► Bottling plants, food industry ► Mixing facilities for the chemicals industry These pressure transducers are made entirely of titanium and therefore have outstanding resistance to corrosion. These convert the pressure-induced deflection of the diaphragm into a change in electrical resistance, which can be ampli-fled, measured and processed by external electronic circuitry. The transducers come in a choice of measuring ranges: up to 20 bar for measurements with respect to atmospheric pressure, or a range of 50 bar and above for measurements with respect to a sealed atmosphere. Technical changes reserved. All data sheets at www.burster.com burster praezisionsmesstechnik gmbh & co kg Germany www.burster.com Talstr. 1-5 Gernsbach 76593 Phone +49-7224-6450 [email protected]

 Open the catalog to page 1
Data Sheet-Pressure Transducer Model 8103-2

Electrical values Bridge resistance: foil strain gauge Excitation voltage: Nominal sensitivity: measuring range 0 ... 5 bar measuring range > 0 ... 10 bar Limit temperature range: Nominal temperature range: Influence of temperature on zero: measuring range 0 ... 5 bar measuring range > 0 ... 10 bar Influence of temperature on sensitivity: Combined error consisting,of non linearity, hysteresis and variation measuring range < 20 bar measuring range > 50 bar Measuring ranges: Dynamic performance: recommended maximum against atmosphere against sealed atmosphere refer to table 400 % over capacity...

 Open the catalog to page 2

All Burster präzisionsmesstechnik gmbh & co kg catalogs and technical brochures

  1. Load cells

    25  Pages

  2. Load-cell

    25  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.