Catalog excerpts
Multichannel Amplifier For strain gauge sensors Operates with up to 4 measuring channels Protected against reverse connection and short-circuit Also available as circuit board without housing Simple configuration using DIP switch High degree of protection up to IP67 Situations often occur in practice in which it is necessary to place a measuring amplifier immediately in the neighborhood of the sensor in order to be able to access a standard signal there. In this way, long distances to the evaluating electronics can be covered. The measuring amplifier itself is powered by voltages between 15 V and 30 V. Internally, the highly accurate, short-circuit protected sensor excitation voltage is generated and used to supply the sensor‘s measuring bridge. The input range of the amplifier is appropriate for sensitivities between 0.5 and 30 mV/V and is also suitable for semiconductor strain gauge. This task can ideally be performed by the 9236 in-line measuring amplifier. With its high degree of protection (IP67) its singlechannel version can be integrated into the application even in the tough environment outside the switch gear cabinet. In the multichannel version, up to four measuring channels can be implemented in one housing for the DIN carrier rail. This means that it can be located either in the switch gear cabinet, or in the immediate neighborhood of the sensor. Users who want to put the amplifier onto an existing circuit board or who wish to construct their own housing can also obtain the amplifier as an open circuit board. It can be integrated by means of screw terminals. The analog output voltage can be set to a range from 0 to ± 5 V or 0 to ± 10 V. DIP switches are used to set the input range. Fine adjustments and zero point setting are performed by means of multi-turn potentiometers that are mounted on the circuit board. The sensors are connected, and the auxiliary power supplied, through user-friendly screw terminals. The amplifier in the IP67 version can, if in fact necessary, be achieved by clamping, gluing, or with the aid of a cable tie. The open circuit board has mounting holes for easy assembly. The amplifier‘s limit frequency is 1 kHz. The 9236 measuring amplifier finds applications wherever the output signal from sensors based on wire strain gauges, such as force, pressure or torque sensors, must be converted into a voltage signal, e.g. ►► ►► ►► ►► Automatic production machinery Laboratory measurements Integration into customer‘s circuit boards Field measurements Technical changes reserved. All data sheets at www.burster.com burster praezisionsmesstechnik gmbh & co kg Germany www.burster.com Talstr. 1-5 . Gernsbach 76593 . Phone +49-7224-6450 info@bur
Open the catalog to page 1Technical Data Terminal assignment for mounting rail version, 2 channel Connectable sensors Strain gauges Bridge resistance: Connection technology: Excitation: Excitation current: Power consumption: Configurable characteristic: Default setting: Analog output Output voltage selectable: 0 ... ± 5 V / 0 ... ± 10 V (standard) selectable Output resistance: 440 Q General amplifier values Measurement error: 0.1 % F.S. Zero point: 25 % / 5 % (standard) of measurement range selectable Temperature coefficient: < 100 ppm/K Zero drift: < 0.4 |jV/K Current consumption: 20 mA / 1 channel Range of...
Open the catalog to page 2All Burster präzisionsmesstechnik gmbh & co kg catalogs and technical brochures
-
SENSOR SOLUTIONS
1 Pages
-
A CONNECTION THAT NETWORKS
1 Pages
-
Quality leading the way
3 Pages
-
Data-Sheet - 9251
6 Pages
-
Data Sheet Model 9210
5 Pages
-
Flyer Load Experts
1 Pages
-
Load cells
25 Pages
-
Data Sheet 8427
7 Pages
-
Displacement Sensors
2 Pages
-
Displacement Sensors
2 Pages
-
Data Sheet Typ 87240
2 Pages
-
Data sheet Typ 8416
6 Pages
-
Load cells
25 Pages
-
Data Sheet Model 8402
6 Pages
-
Flyer Load Experts
1 Pages
-
Data Sheet - Model 8438
6 Pages
-
Data Sheet Model 8400-B001
2 Pages
-
Sensor Solutions
1 Pages
-
A Connection that Networks
1 Pages
-
Qualitiy leading the way
3 Pages
-
Data Sheet Model 9250
7 Pages
-
Torque Sensors
9 Pages
-
Data Sheet Typ 8656
7 Pages
-
Data Sheet Model 9235
2 Pages
-
Data sheet Model 8435
7 Pages
-
Data Sheet Typ 8417
7 Pages
-
Data Sheet Typ 8532
2 Pages
-
Torque Sensors
9 Pages
-
Data Sheet Typ 8627
2 Pages
-
Data Sheet Model 8527
7 Pages
-
Data Sheet Model 8526
9 Pages
-
Data Sheet Typ 8655
7 Pages
-
Data Sheet Model 8431
12 Pages
-
Pressfitting -the reliable way
11 Pages
-
Data Sheet Typ 9311
6 Pages
-
Data Sheet Model 8511
6 Pages
-
Data Sheet - DIGISTANT® 4463
5 Pages
-
Data sheet Series 8738
2 Pages
-
Torque Sensors
16 Pages
-
Data Sheet Model 8630
6 Pages
-
Data Sheet Typ 8625
7 Pages
-
Data Sheet Models 8710, 8711
2 Pages
-
Data Sheet Typ 8740/8741
4 Pages
-
Data Sheet Models 8712, 8713
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8451
7 Pages
-
Procision to the core
3 Pages
-
Flyer Battery Tester
1 Pages
-
Data Sheet Model 2560
5 Pages
-
Data Sheet Model 8561
6 Pages
-
Data Sheet Model 2311
5 Pages
-
Data Sheet Model 8523
8 Pages
-
Data Sheet Series 87350
2 Pages
-
Data Sheet Model 9243
2 Pages
-
Operation manual
76 Pages
-
Data Sheet Typ 8739
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8565
5 Pages
-
Data sheet Model 8631
5 Pages
-
Data Sheet Model 8718
2 Pages
-
Data Sheet Typ 8512
5 Pages
-
Data-Sheet- Model 8228
6 Pages
-
Data Sheet Model 8510
5 Pages
-
Data Sheet Model 8415
6 Pages
-
Data Sheet Model 2511
6 Pages
-
RESISTOMAT® Model 2329
4 Pages
-
Data Sheet Model 8524
8 Pages
-
Data Sheet Model 2550
4 Pages
-
Data Sheet Model 9186/8532
2 Pages
-
Data Sheet Typ 8645
5 Pages
-
Data sheet Model 8709
2 Pages
-
Flyer Displacement Sensor
2 Pages
-
Data Sheet - Model 8670
4 Pages