Delivery: ex stock | Warranty: 24 months Press Load Cell for hand and automatic operated presses MODEL 8451 Highlights Measuring ranges from 0 … 500 N up to 0 … 100 kN Non-linearity < 0,25 % F.S. Protection class IP65 / IP67 Simplest mounting on press ram Robust construction with mechanical overload protection Applications Forces in component joining Press-fitting Bending forces during material deformation Cutting forces when severing materia Forces during stamping processes Punching forces for blanks Break-out forces used in destructive testing Measuring ranges 0 ... 50 kN up to 0 ... 100 kN Product description The Load cell model 8451 has been developed for measuring the forces that occur during press operation. The internal measuring elements have a rugged design, which mean they can cope reliably with the steep force curves that are typical of press applications. They can be fitted or replaced quickly and easily on the press ram without the need for additional components around them. The force sensor is placed between the tool and the press ram and can thus measure the actual compression force directly in the axis of operation. The load cell measures the compression forces between the circular contact surfaces of plunger and tool. The pin on its top side and hole on its lower face are simply provided for mechanical fixing and centering the components correctly. The connecting cables are suitable for drag chains, designed for many movements and stably fastened in the sensor housing. Attachments are available which clamp onto the press sensors to enable easy mounting of displacement sensors according to the circumstances of use. burster Sensors and Process Instruments – Technical changes reserved. All data sheets at www.burster.
Open the catalog to page 1Measuring range calibrated in N and kN from 0 ... Accuracy Relative non-linearity* Characteristic curve deviation* Relative hysteresis Temperature effect on zero output Temperature effect on nominal sensitivity Electrical value Sensitivity nominal Measurement direction Compression direction Bridge resistance 350 Ω nominal (deviations are possible) Insulation resistance Environmental conditions Nominal temperature range Operating temperature range Mechanical values Deflection full scale Maximum operating force 120 % of nominal load (after that overload protection takes effect) Max. static load...
Open the catalog to page 2Dimensional drawing 1 – Measuring ranges from ≤ 0 ... 2 kN | from ≤ 0 ... 450 lbs Ø 25 Option Standardization, TEDS Cable extension Contact surfaces for force transmission Dimensional drawing 2 – Measuring ranges from ≥ 0 ... 5 kN up to ≤ 0 ... 20 kN | from ≥ 0 ... 1.1 klbs up to ≤ 0 ... 4.5 klbs Ø 25 Contact surfaces for force transmission Option Standardization, TEDS Cable extension Dimensional drawing 3 – Measuring ranges from ≥ 0 ... 50 kN | from ≥ 0 ... 11.25 klbs Ø 43 Contact surfaces for force transmission Option Standardization, TEDS Cable extension burster Sensors and Process Instruments...
Open the catalog to page 3Electrical termination Output signal burster load cells are based on a strain-gage Wheatstone bridge. This measurement principle means that the output voltage mV/V is highly dependent on the sensor supply voltage. Our website contains details of suitable instrumentation amplifiers, indicator and display devices and process instruments. Excitation + (white) Output signal - (green) burster burster TEDS The "burster Transducer Electronic Data Sheet" (TEDS) is a memory in which identification data of the sensor, calibration data and other sensor parameters are saved. In conjunction with your own...
Open the catalog to page 4Examples Example showing use of mounting parts to fit displacement sensor Model 5501-Z002 The displacement sensor is mounted on the press head. Its push rod rests on the bracket that is clamped onto the load cell. Example of a measuring chain Load cell Displacement sensor Connector plug Fitting of plug Mounting parts ForceMaster Analysis and configuration software 9110-P001 1> Displacement sensor e.g. Mode 8713-50 PLC sequence control function (optional) USB-Stick (optional) Mounting parts Typ 5501-Z002 Typ 5501-Z003 Presses load cell Model 8451 Tool change with special tool cards Different acoustic...
Open the catalog to page 5Calibration Test and calibration certificate Supplied with the sensor Amongst other data, includes figures for zero point, full-scale output and calibration offset Standard factory calibration certificate for load cells or measurement chains (WKS) Optionally available Our standard factory calibration is performed in 20% steps starting from zero until the reaching the nominal force, for increasing and decreasing load with unchanged installation position. Factory calibration is performed in the compression direction. Special factory calibration certificate for load cells or measurement chains (WKS)...
Open the catalog to page 6Order Code Measuring range 0 ... 500 Delivery ex stock at short notice N 8 Nominal sensitivity/not standardized tandardization at 0.8 mV/V S (not possible for measuring ranges 0 ... 5 kN and 0 ... 10 kN) Connection cable 1.7 m (with standardization in the cable 2 m) Connection cable 3 m extended * Connection cable 5 m extended * (with sens line) * shortened delivery time compared with cable length 3 m and 5 m in one piece Open cable ends + 6 cm single wires 9 pins Sub-D connector model 9900-V209 9 pins Sub-D connector model 9900-V209 for 9163-V3xxxx 12 pins round connector model 9941 for burster...
Open the catalog to page 75 Pages
7 Pages
76 Pages
8 Pages
6 Pages
7 Pages
25 Pages
5 Pages
6 Pages
5 Pages
6 Pages
5 Pages
5 Pages
2 Pages
2 Pages
6 Pages
2 Pages
25 Pages
5 Pages
9 Pages
7 Pages
5 Pages
6 Pages
6 Pages
7 Pages
7 Pages
2 Pages
7 Pages
7 Pages
7 Pages
9 Pages
1 Page
6 Pages
6 Pages
14 Pages
2 Pages
6 Pages
5 Pages
6 Pages
7 Pages
2 Pages
2 Pages
2 Pages
7 Pages
8 Pages
2 Pages
2 Pages
7 Pages
5 Pages
6 Pages
7 Pages
5 Pages
2 Pages
6 Pages
5 Pages
8 Pages
9 Pages
7 Pages
6 Pages
7 Pages
7 Pages
6 Pages
6 Pages
11 Pages
2 Pages
2 Pages
1 Page
1 Page
2 Pages
2 Pages
1 Page
5 Pages
76 Pages
2 Pages
4 Pages
4 Pages
5 Pages
2 Pages
4 Pages
6 Pages