Catalog excerpts
Amplifier Module for strain gauge and potentiommetrio sensorsModel 9243 Code: 9243 EN ■ Accuracy < 0.05 % ■ Outputs ± 5 V, ±10 V and 0 (4) - 20 mA ■ 6 wire technique ■ Isolation between signal and power supply ■ Cut-off frequency 1 kHz, optional 4 kHz ■ Configuration via DIP switches ■ Easy installation on DIN mounting rail Application The amplifier module model 9243 is used wherever measurement signals from strain gauges, potentiometric sensors or DC/DC sensors have to be converted into standard signals. Simply by mounting on conventional DIN-mount rails, it is possible to position the amplifier module on location, in the proximity of the sensor. Especially for rough environments a IP65 version is available. The broad auxiliary power range and the choice between AC or DC permits operation on standard power supplies used in switch gear cabinets. A highly precise reference voltage source is built-in for calibration purposes. A calibrating shunt can also be connected via two separate terminals. This permits deliberate detuning of a strain gauge sensor for calibration or merely to check the measuring chain. Description A highly accurate precision amplifier performs the amplification of the sensor signal being applied. The necessary gain factor is adjusted coarsely with DIP switches while fine-tuning is carried out by using a potentiometer. Current and voltage outputs are available simultaneously. The sensor excitation is performed by the amplifier module itself so that no additional voltage source is required. It can also be set in steps of 2.5 V, 5 V, 10 V using DIP switches. The maximum feed current of 35 mA permits parallel connection of several strain gages, e.g. for the addition of measurement variables. Measurement errors brought about by varying line lengths or due to temperature fluctuations effecting the sensor cable are avoided by having probe lines measuring the actual feed voltage directly on site at the sensor itself (6 wire technology). Fluctuations are immediately corrected electronically. The cut-off frequency of the amplifier can be switched between 10 Hz and 1 kHz. The DIP switches for configuring the entire device are found easily accessible, under a cover. Technical changes reserved. All data sheets at www.burster.com burster praezisionsmesstechnik gmbh & co kg Germany www.burster.com Talstr. 1-5 ■ Gernsbach 76593 ■ Phone +49-7224-6450 info@burster.com
Open the catalog to page 1Technical Data Connection Schematic Connectable sensors Strain gauges ► for strain gauge sensors, e.g. force, pressure or torque sensors + Excitation Bridge resistances: Connection technology: Sensitivity: Excitation voltage: Excitation current: 1 kΩ ... 5 kΩ 3 wire 0 V ... 5 V 5V max. 35 mA selectable via DIP switches Voltage output: max. 11.5 V at open terminals ±10 V Current output: 0 ... 20 mA or 4 ... 20 mA Load: 200 ... 500 Ω Input impedance: 1 GΩ Output impedance: with 10 V output: 470 Ω with monitor output: 10 kΩ General amplifier data Gain: 0.5 ... 50 000 (via DIP switches +...
Open the catalog to page 2All Burster präzisionsmesstechnik gmbh & co kg catalogs and technical brochures
-
SENSOR SOLUTIONS
1 Pages
-
A CONNECTION THAT NETWORKS
1 Pages
-
Quality leading the way
3 Pages
-
Data-Sheet - 9251
6 Pages
-
Data Sheet Model 9210
5 Pages
-
Flyer Load Experts
1 Pages
-
Load cells
25 Pages
-
Data Sheet 8427
7 Pages
-
Displacement Sensors
2 Pages
-
Displacement Sensors
2 Pages
-
Data Sheet Typ 87240
2 Pages
-
Data sheet Typ 8416
6 Pages
-
Load cells
25 Pages
-
Data Sheet Model 8402
6 Pages
-
Flyer Load Experts
1 Pages
-
Data Sheet - Model 8438
6 Pages
-
Data Sheet Model 8400-B001
2 Pages
-
Sensor Solutions
1 Pages
-
A Connection that Networks
1 Pages
-
Qualitiy leading the way
3 Pages
-
Data Sheet Model 9250
7 Pages
-
Torque Sensors
9 Pages
-
Data Sheet Typ 8656
7 Pages
-
Data Sheet Model 9235
2 Pages
-
Data sheet Model 8435
7 Pages
-
Data Sheet Typ 8417
7 Pages
-
Data Sheet Typ 8532
2 Pages
-
Torque Sensors
9 Pages
-
Data Sheet Typ 8627
2 Pages
-
Data Sheet Model 8527
7 Pages
-
Data Sheet Model 8526
9 Pages
-
Data Sheet Typ 8655
7 Pages
-
Data Sheet Model 8431
12 Pages
-
Pressfitting -the reliable way
11 Pages
-
Data Sheet Typ 9311
6 Pages
-
Data Sheet Model 8511
6 Pages
-
Data Sheet - DIGISTANT® 4463
5 Pages
-
Data sheet Series 8738
2 Pages
-
Torque Sensors
16 Pages
-
Data Sheet Model 8630
6 Pages
-
Data Sheet Typ 8625
7 Pages
-
Data Sheet Models 8710, 8711
2 Pages
-
Data Sheet Typ 8740/8741
4 Pages
-
Data Sheet Models 8712, 8713
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8451
7 Pages
-
Procision to the core
3 Pages
-
Flyer Battery Tester
1 Pages
-
Data Sheet Model 2560
5 Pages
-
Data Sheet Model 8561
6 Pages
-
Data Sheet Model 2311
5 Pages
-
Data Sheet Model 8523
8 Pages
-
Data Sheet Series 87350
2 Pages
-
Operation manual
76 Pages
-
Data Sheet Typ 8739
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8565
5 Pages
-
Data sheet Model 8631
5 Pages
-
Data Sheet Model 8718
2 Pages
-
Data Sheet Typ 8512
5 Pages
-
Data-Sheet- Model 8228
6 Pages
-
Data Sheet Model 8510
5 Pages
-
Data Sheet Model 8415
6 Pages
-
Data Sheet Model 2511
6 Pages
-
RESISTOMAT® Model 2329
4 Pages
-
Data Sheet Model 8524
8 Pages
-
Data Sheet Model 2550
4 Pages
-
Data Sheet Model 9186/8532
2 Pages
-
Data Sheet Typ 8645
5 Pages
-
Data sheet Model 8709
2 Pages
-
Flyer Displacement Sensor
2 Pages
-
Data Sheet - Model 8670
4 Pages