Delivery: ex stock | Warranty: 24 months Press Load Cell for hand and automatic operated presses MODEL 8552 Highlights Measuring ranges from 0 … 100 N up to 0 … 25 kN Small, compact design Pin/hole diameter from 8 mm to 16 mm Different diameter for pin and hole can be combined Mechanical overload protection for all measurement ranges Applications Forces in component joining Press-fitting Bending forces during material deformation Cutting forces when severing material Forces during stamping processes Punching forces for blanks Flexible mechanical adaption Break-out forces used in destructive testing Product description Simple adapter mounting Flexible configuration of hole and pin The load cell measures the compression forces between the circular contact surfaces of plunger and tool. The pin on its top side and hole on its lower face are simply provided for mechanical fixing and centering the components correctly. To provide as large a range of mechanical compatibility as possible, the pins/holes are available in different diameters. Attachments are available which clamp onto the press sensors to enable easy mounting of displacement sensors according to the circumstances of use. Mounting potentiometric displacement sensors of the 871x model series burster Sensors and Process Instruments – Technical changes reserved. All data sheets at www.burster.

 Open the catalog to page 1
Data sheet Model 8552/Model 8451-2

Measuring range calibrated in N and kN from 0 ... Accuracy Relative non-linearity* Characteristic curve deviation* Relative hysteresis Temperature effect on zero output Temperature effect on nominal sensitivity Electrical value Sensitivity nominal Measurement direction Compression direction Bridge resistance 350 Ω nominal (deviations are possible) Insulation resistance Environmental conditions Nominal temperature range Operating temperature range Mechanical values Deflection full scale Maximum operating force 120 % of nominal load (after that overload protection takes effect) Max. static load...

 Open the catalog to page 2
Data sheet Model 8552/Model 8451-3

Dimensional drawing Contact surfaces for force transmission Option Standardization, TEDS Cable extension Electrical termination Output signal burster load cells are based on a strain-gage Wheatstone bridge. This measurement principle means that the output voltage mV/V is highly dependent on the sensor supply voltage. Our website contains details of suitable instrumentation amplifiers, indicator and display devices and process instruments. Excitation + (white) Output signal - (green) burster burster TEDS The "burster Transducer Electronic Data Sheet" (TEDS) is a memory in which identification...

 Open the catalog to page 3
Data sheet Model 8552/Model 8451-4

Accessories Connectors and units Order code Connectors 9941 Connectors 12 pin, suitable to all burster desktop units Connectors 9 pin, suitable to SENSORMASTER, DIGIFORCE® and TRANS CAL Connectors 9 pin with TEDS Connectors 8 pin, suitable to ForceMaster Potentiometric displacement transducers Mounting potentiometric displacement sensors of the 871x model series ForceMaster 9110 - Monitoring for hand presses Sensor electronics, amplifier and process control units like digital indicator model 9180, model 9163, modular amplifier model 9250 or DIGIFORCE® Model 9307 Examples Example showing use of...

 Open the catalog to page 4
Data sheet Model 8552/Model 8451-5

Calibration Test and calibration certificate Supplied with the sensor Amongst other data, includes figures for zero point, full-scale output and calibration offset Standard factory calibration certificate for load cells or measurement chains (WKS) Optionally available Our standard factory calibration is performed in 5 force steps (20% steps) starting from zero until the reaching the nominal force, for increasing and decreasing compression load under the same installation position. Special factory calibration certificate for load cells or measurement chains (WKS) On request We are happy to calibrate...

 Open the catalog to page 5
Data sheet Model 8552/Model 8451-6

Order Code Measuring range 0 ... 100 klbs klbs Delivery ex stock at short notice N 8 Nominal sensitivity/not standardized Connection cable 1.7 m (with standardization in the cable 2 m) Connection cable 3 m extended * Connection cable 5 m extended * (with sens line) * shortened delivery time compared with cable length 3 m and 5 m in one piece Open cable ends + 6 cm single wires 9 pins Sub-D connector model 9900-V209 9 pins Sub-D connector model 9900-V209 for 9163-V3xxxx 12 pins round connector model 9941 for burster desktop devices 8 pins coupling connector model 9900-V245 with sensor datas for...

 Open the catalog to page 6