Delivery: ex stock | Warranty: 24 months Compression Load Cell MODEL 8526 Highlights Measuring ranges from 0 ... 100 N to 0 ... 1 MN Extremely compact design For static and dynamic measurements T hree threaded holes on bottom for easy mounting and cable suitable for drag chain application Protection class IP64 Options Non-linearity 0.1% F.S. Standardized output signal burster TEDS Applications All forms of test benches Reference sensor for comparative and for calibration jobs In cramped assembly situations Product description Small measuring ranges Wide measuring range 500 kN Thanks to its compact shape and three fixing holes on its underside, the 8526 compression load cell can be used in a variety of applications. With its wide choice of measuring ranges from 0 ... 100 N up to 0 ... 1 MN, it really can cover a wealth of measurement tasks, from the laboratory to use in heavy industry. The integral load button provides an easy and reliable means of applying the force to be measured. Angle errors in the load application with a deviation from the measurement axis of up to 3° have only a minor influence on the measurement signal. For ideal measurement accuracy, the load cell should be mounted on a surface that has been ground and has a hardness of at least 60 HRC. Wide measuring range 1 MN The model 8526 load cell is designed with an internal elastic membrane, to which strain gages are attached. When a compressive load is applied to the load cell, the membrane is elastically deformed and transfers its tension to the strain gages. These in turn respond with a proportional change in their ohmic resistance, which can be evaluated using a suitable instrumentation amplifier or display device. burster Sensors and Process Instruments – Technical changes reserved. All data sheets at www.burster.com
Open the catalog to page 1Measuring range calibrated in N and kN from 0 ... Accuracy Relative non-linearity* Characteristic curve deviation* Relative hysteresis Temperature effect on zero output Temperature effect on nominal sensitivity Electrical values Sensitivity nominal Measurement direction Compression direction Bridge resistance Insulation resistance Environmental conditions Nominal temperature range Operating temperature range Mechanical values Deflection full scale Maximum operating force Overload burst Dynamic performance recommended: 50 %; maximum: 70 % (of capacity) Installation Intended mounting screws Tightening...
Open the catalog to page 2Measuring range calibrated in N and kN from 0 ... Accuracy Relative non-linearity* Characteristic curve deviation* Relative hysteresis Temperature effect on zero output Temperature effect on nominal sensitivity Electrical values Sensitivity nominal Measurement direction Bridge resistance Insulation resistance Environmental conditions Nominal temperature range Operating temperature range Mechanical values Deflection full scale Maximum operating force Overload burst Dynamic performance recommended: 50 %; maximum: 70 % (of capacity) Installation Intended mounting screws Tightening torque mounting...
Open the catalog to page 3Dimensional drawing 1 – Measuring ranges from 0 ... 0.1 kN up to 0 ... 200 kN | from 0 ... 22.4 lbs up to 0 ... 45.0 klbs Measuring range from 0 ... Option Standardization, TEDS L/B/D 90/8/7 Cable extension General tolerance of dimension burster Sensors and Process Instruments – Technical changes reserved. All data sheets at ww
Open the catalog to page 4Dimensional drawing 2 – Measuring range from 500 kN | 112 klbs Measuring range from 0 ... General tolerance of dimension burster Sensors and Process Instruments – Technical changes reserved. All data sheets
Open the catalog to page 5Dimensional drawing 3 – Measuring range from 1 MN | 225 klbs Ø D4 Measuring range from 0 ... General tolerance of dimension burster Sensors and Process Instruments – Technical changes reserved. All data sheets a
Open the catalog to page 6Electrical termination Output signal burster load cells are based on a strain-gage Wheatstone bridge. This measurement principle means that the output voltage mV/V is highly dependent on the sensor supply voltage. Our website contains details of suitable instrumentation amplifiers, indicator and display devices and process instruments. Electrical termination at measuring range Messbereich up to 0 ... 200 kN Electrical termination at measuring range 0 ... 500 kN and 0 ... 1 MN Output signal - (green) Excitation - (brown) Output signal + (yellow) Sensor - (grey)* TEDS I/O (red)** TEDS GND (blue)**...
Open the catalog to page 7Accessories Connectors and units Order Code Connection cable 99643-000A-0570030 Connection cable for measuring ranges 500 kN and 1 MN, length 3 m, open ends on one side Connectors 12 pin, suitable to all burster desktop units Connectors 9 pin, suitable to SENSORMASTER, DIGIFORCE® and TRANS CAL Connectors 9 pin with TEDS Connectors 8 pin, suitable to ForceMaster Mobile measuring device with strain gage simulator and sensor test (Ri, Ra, Shunt, RISO) Sensor electronics, amplifier and process control units like digital indicator model 9180, model 9163, modular amplifier model 9250 or DIGIFORCE®...
Open the catalog to page 8Order Code Measuring range 0 ... Delivery ex stock at short notice N 8 Nominal sensitivity/not standardized Connection cable 1.7 m (Standardization 2 m) Connection cable 3 m extended * Connection cable 5 m extended * (with sens line) * shortened delivery time compared with cable length 3 m and 5 m in one piece Open cable ends + 6 cm single wires 9 pins Sub-D connector model 9900-V209 9 pins Sub-D connector model 9900-V209 for 9163-V3xxxx 12 pins round connector model 9941 for burster desktop devices 9 pins Sub-D connector with burster TEDS model 9900-V229 8 pins coupling connector model 9900-V245...
Open the catalog to page 95 Pages
7 Pages
76 Pages
8 Pages
6 Pages
7 Pages
25 Pages
5 Pages
6 Pages
5 Pages
6 Pages
5 Pages
5 Pages
2 Pages
2 Pages
6 Pages
2 Pages
25 Pages
5 Pages
9 Pages
7 Pages
5 Pages
6 Pages
6 Pages
7 Pages
7 Pages
2 Pages
7 Pages
7 Pages
7 Pages
9 Pages
1 Page
6 Pages
6 Pages
14 Pages
2 Pages
6 Pages
5 Pages
6 Pages
7 Pages
2 Pages
2 Pages
2 Pages
7 Pages
8 Pages
7 Pages
2 Pages
2 Pages
7 Pages
5 Pages
6 Pages
7 Pages
5 Pages
2 Pages
6 Pages
5 Pages
8 Pages
7 Pages
6 Pages
7 Pages
7 Pages
6 Pages
6 Pages
11 Pages
2 Pages
2 Pages
1 Page
1 Page
2 Pages
2 Pages
1 Page
5 Pages
76 Pages
2 Pages
4 Pages
4 Pages
5 Pages
2 Pages
4 Pages
6 Pages