Delivery: ex stock | Warranty: 24 months Miniature Bending Beam Tension and Compression Load Cell ■ Measuring ranges from 0 ... 1 N up to 0 ... 20 N, 0 ... 0.224 lbs up to 0 ... 4.4 lbs ■ Mechanical bidirectional overload protection ■ Special design upon request ■ Standardized nominal sensitivity ■ Check of switches and buttons (limit-, micro- and toggle-switches) ■ Contact coupling and contact decoupling forces ■ Recording of frictional forces and spring characteristics The sensor element consists of a double bending beam with applied strain gages. Changes in the ohmic resistance of the strain gage fullbridge caused by applied forces are converted into electrical voltages. The precise value (characteristic value) of the output voltage, resulting from the application of a rated force to the sensor, is specified in the accompanying calibration protocol. The sensor has to be mounted by two screws on the cable side. The opposite side is meant to receive applied forces (loads). Once the rated stress or strain is exceeded by 20 %, further deflection of the bending beam is prevented by an integrated, mechanical stop. This protects the sensor element against permanent deformation. Sensor attachment Bending protection burster Sensors and Process Instruments - Technical changes reserved. All data sheets at www.burster.com
Open the catalog to page 1Relative non-linearity* Characteristic curve deviation* Relative hysteresis Temperature effect on zero output Temperature effect on nominal sensitivity Electrical values Sensitivity nominal Measurement direction Standardization** Bridge resistance Insulation resistance Tension and compression direction. Load calibration in compression direction (clearly marked by an arrow on the sensor). The full-scale output is likely to be different when used in the tension direction. Positive signal 350 Q nominal (deviations are possible) Environmental conditions Nominal temperature range Operating temperature...
Open the catalog to page 2Electrical terminationOutput signal burster load cells are based on a strain-gage Wheatstone bridge. This measurement principle means that the output voltage mV/V is highly dependent on the sensor supply voltage. Our website contains details of suitable instrumentation amplifiers, indicator and display devices and process instruments. The "burster Transducer Electronic Data Sheet" (TEDS) is a memory in which identification data of the sensor, calibration data and other sensor parameters are saved. In conjunction with your own suitable burster device, there is the option of performing a simple...
Open the catalog to page 3Order Code burster Sensors and Process Instruments - Technical changes reserved. All data sheets at www.burster.com
Open the catalog to page 4Order Code Measuring range ±1 N ±2 N ±5 N Nominal sensitivity/not standardized ' temperature range limited to 0 ... +60 °C Connection cable 1.7 m (Standardization 2 m Connection cable 3 m Connection cable 3 m extended * Connection cable 5 m extended * (with sens line shortened delivery time compared with cable length 3 m and 5 m in one piece *** temperature range limited to 0 ... +60 °C ** The data in the area 20 % - 100 % of rated load Fnom Note ■ Brochure Our brochure „Load cells for production, automation, R&D and quality assurance" is available for download on our website. It conatains numerous...
Open the catalog to page 55 Pages
7 Pages
76 Pages
8 Pages
6 Pages
7 Pages
25 Pages
6 Pages
5 Pages
6 Pages
5 Pages
5 Pages
2 Pages
2 Pages
6 Pages
2 Pages
25 Pages
5 Pages
9 Pages
7 Pages
5 Pages
6 Pages
6 Pages
7 Pages
7 Pages
2 Pages
7 Pages
7 Pages
7 Pages
9 Pages
1 Page
6 Pages
6 Pages
14 Pages
2 Pages
6 Pages
5 Pages
6 Pages
7 Pages
2 Pages
2 Pages
2 Pages
7 Pages
8 Pages
7 Pages
2 Pages
2 Pages
7 Pages
5 Pages
6 Pages
7 Pages
5 Pages
2 Pages
6 Pages
5 Pages
8 Pages
9 Pages
7 Pages
6 Pages
7 Pages
7 Pages
6 Pages
6 Pages
11 Pages
2 Pages
2 Pages
1 Page
1 Page
2 Pages
2 Pages
1 Page
5 Pages
76 Pages
2 Pages
4 Pages
4 Pages
5 Pages
2 Pages
4 Pages
6 Pages