Delivery: ex stock | Warranty; 24 months Miniatur Compression Load Cell NEW option: Dual-range in different spreadings Highlights ■ Measuring ranges from 0 ... 1 kN up to 0 ... 100 kN ■ Connecting cable suitable for drag chains ■ Made of stainless steel ■ Standardized output signal 1.5 mV/V ■ Dual range model ■ Connecting cable attached centrally from below ■ Form-fitted to prevent rotation ■ Press-in force measurements on longitudinal and transversal connections ■ Compression force measurements on punch and roller applicancy ■ Spring tension measurements on shock absorbers for cars ■ Contact pressure determination in push rods ■ Compression force measurements on compressed-air knee-lever presses This, related to its measuring range, miniaturized load cell enables an universal and reliable operation in industries and laboratories. It is well suited for compression measurements in very restricted structures. The load cell is a compact construction and made of stainless steel. Therefore it can be used in many fields of industry. Thanks to the rounded top, in shape of a little hat, the force to be measured is led into the sensor centrically and free of lateral force. Strain gauges arranged in a full bridge are applied on the generated surface of the sensor. By applying a force to the strain gauge bridge the resistance change of the strain gauges is transformed into an output voltage which is directly proportional to the measured force. The load cells have to be mounted complete on a smooth, plane parallel surface. They can be fixed with contact glue or silicone. To achieve optimum measurement accuracy, protect the sensor from off-axis loads that will result in lateral or side forces. Clamping forces must not be applied laterally to the circumferential surface of the sensor. During installation or mounting you have to take care that the cable outlet and the cable of the load cell are not stressed by tension and bending forces. In the connection cable of the sensor, the output signal is standardized to 1.5 mV/V, so that an exchange can easily be done, without the need to re-adjust the processing electronics. burster Sensors and Process Instruments - Technical changes reserved. All data sheets at www.burster.com
Open the catalog to page 1Relative non-linearity* Characteristic curve deviation* Relative hysteresis Temperature effect on zero output Temperature effect on nominal sensitivity Electrical values Sensitivity nominal Measurement direction Bridge resistance Insulation resistance compression direction realized on board in connection cable, 1.7 m from sensor housing or 0.3 m from cable end 350 Q nominal (deviations are possible) Environmental conditions Nominal temperature range Operating temperature range Deflection full scale Maximum operating force Overload burst Dynamic performance Protection class Natural frequency Weight...
Open the catalog to page 2burster Sensors and Process Instruments - Technical changes reserved. All data sheets at www.burster.com
Open the catalog to page 3Electrical termination Output signal burster load cells are based on a strain-gage Wheatstone bridge. This measurement principle means that the output voltage mV/V is highly dependent on the sensor supply voltage. Our website contains details of suitable instrumentation amplifiers, indicator and display devices and process instruments. Sensor + (pink)* Excitation + (white) Output signal - (green) Excitation - (brown) Output signal + (yellow) Sensor - (grey)* only for extended cables of length 5 m or more option burster Sensors and Process Instruments - Technical changes reserved. All data sheets...
Open the catalog to page 4Calibration Test and calibration certificate Dual-range in different spreadings Dual-range model As an optional extra, an additional calibration certificate is available for a second measuring range that is Optionally available smaller by one step. For example, for the measuring range 0 ... 20 kN also a calibration certificate for 0 ... 10 kN. Depending on the measuring range, this results in a dual range ratio of 1:2 or 1:2.5. burster Sensors and Process Instruments - Technical changes reserved. All data sheets at www.burster.com
Open the catalog to page 5Measuring range ‘ shortened delivery time compared with cable length 3 m and 5 m in one piece Calibration 1:2 / 1:2.5 dual-range option Non-linearity according to specification ‘ The data in the area 20 % - 100 % of rated load F Nominal temperature range +15 °C ... +70 °C ■ Brochure Our brochure „Load cells for production, automation, R&D and quality assurance" is available for download on our website. It conatains numerous applications, detailed product specifications and overviews. ■ Product videos Watch our How-to-do video at: www.youtube.com/bursterVideo Youl Tube ■ CAD data Download via...
Open the catalog to page 65 Pages
7 Pages
76 Pages
8 Pages
6 Pages
7 Pages
25 Pages
5 Pages
6 Pages
5 Pages
6 Pages
5 Pages
5 Pages
2 Pages
2 Pages
6 Pages
2 Pages
25 Pages
5 Pages
9 Pages
7 Pages
5 Pages
6 Pages
6 Pages
7 Pages
7 Pages
2 Pages
7 Pages
7 Pages
7 Pages
9 Pages
1 Page
6 Pages
14 Pages
2 Pages
6 Pages
5 Pages
6 Pages
7 Pages
2 Pages
2 Pages
2 Pages
7 Pages
8 Pages
7 Pages
2 Pages
2 Pages
7 Pages
5 Pages
6 Pages
7 Pages
5 Pages
2 Pages
6 Pages
5 Pages
8 Pages
9 Pages
7 Pages
6 Pages
7 Pages
7 Pages
6 Pages
6 Pages
11 Pages
2 Pages
2 Pages
1 Page
1 Page
2 Pages
2 Pages
1 Page
5 Pages
76 Pages
2 Pages
4 Pages
4 Pages
5 Pages
2 Pages
4 Pages
6 Pages