Universal High Voltage Battery Controller for analysis, testing and diagnosis Preliminary data sheet Highlights V oltage measurement of 0 … 100 VDC to 0 … 900 VDC A C resistance range (impedance) 0 … 100 mΩ and 0 … 100 Ω R esistance measuring range 0 … 1 mΩ and 0 … 3 Ω F requency range 1 Hz … 1 kHz E xtremely compact, easy to operate Areas of application The extremely compact, universal battery controller is one of the world's first devices for measuring the spectral impedance of low and high voltage battery systems. It is predestined for troubleshooting in development/laboratory or manufacturing areas, for analyzing operating behavior in the test phase or for “rapid diagnostics” in the support area. Irrespective of the technology, batteries or accumulators can be tested in a reliable, fast and safe way. S tandard battery tests T arget/actual comparisons D iagnosis function (status determination) B attery analyses Product description The model 2550 universal battery controller operates in accordance with the well-tried four-conductor measuring method, and combines the functionality of a battery tester and a battery analyzer, making it possible to carry out rapid testing of batteries and accumulators irrespective of the technology. As well as high-voltage batteries, low voltage batteries (e.g. 12 VDC, 24 VDC or 48 VDC) can also be measured and diagnosed. The power is supplied and the measurements are read out via the galvanically isolated USB interface. Parameterization, visualization and operation take place via the intuitively operated PC software. The battery test function records the battery voltage and the internal resistance at a fixed frequency. An OK/NOK statement can be derived by means of comparison with target values. The charge status and capacitance (health) can be diagnosed by comparing the battery data. Signs of aging can be detected at an early stage in this way by examining changes over time. With the battery analysis function, the battery voltage and also the internal resistance can be measured via the frequency (spectral impedance). Other battery parameters can be derived using the frequency curve, e.g. the model parameters of the equivalent circuit, from which conclusions can be drawn about the load behavior of the battery. For example, information about damage can be obtained via deviations of the curve from characteristic values. burster – Technical changes rese
Open the catalog to page 1![Data Sheet Model 2550 - 2](https://img.directindustry.com/pdf/repository_di/13615/data-sheet-model-2550-1037019_2m.jpg)
Technical data DC battery voltage measurement Range (adjustable) Measuring accuracy Input impedance AC resistance measuring ranges Impedance measuring range (Uac ≤ 200 mVss at the battery) Measuring current 0…1Ω 200 mAss, discharging (unipolar) Resolution Measuring accuracy Frequency range Range Time interval for single measurement Time interval for entire spectrum Type of measurement Ambient conditions Operating temperature Storage temperature Humidity General data Communication interface Power supply Current consumption Size Weight Protection class Protection type Measuring category EMV /...
Open the catalog to page 2![Data Sheet Model 2550 - 3](https://img.directindustry.com/pdf/repository_di/13615/data-sheet-model-2550-1037019_3m.jpg)
Calibration / test interval We recommend periodic checking at 12 monthly intervals. To do this, please send the device to us. Principle of operation The battery controller operates in accordance with the four-conductor method (Kelvin connection) and has 4 connections for impedance measurement: 2 connections for power input (Force + and Force -) and 2 connections for voltage measurement (Sense + and Sense -). The battery controller applies an AC current IAC that is relatively small in relation to the load current to the test object (battery, accumulator), and measures the resulting voltage...
Open the catalog to page 3![Data Sheet Model 2550 - 4](https://img.directindustry.com/pdf/repository_di/13615/data-sheet-model-2550-1037019_4m.jpg)
Analysis and diagnosis PC software The innovative, intuitively operated PC software for battery controller model 2550 is used wherever comprehensive visual analyses, diagnoses, battery condition determination or target/actual comparisons are to be carried out on battery cells or accumulators. C onvenient device configuration via USB interface M anagement of different operating modes can be defined V iewer function B ackup of settings M easurement data logging of the analysis and diagnosis data, including results H andover of test object designations for measurement data logging E xporting...
Open the catalog to page 4All Burster präzisionsmesstechnik gmbh & co kg catalogs and technical brochures
-
Press fitting - the reliable way
11 Pages
-
Data Sheet Typ 9307
6 Pages
-
Data Sheet Model 2511
6 Pages
-
Data Sheet Typ 8625
7 Pages
-
Data Sheet Model 9243
2 Pages
-
Data Sheet- Model 2500
2 Pages
-
SENSOR SOLUTIONS
1 Pages
-
A CONNECTION THAT NETWORKS
1 Pages
-
Quality leading the way
3 Pages
-
Data-Sheet - 9251
6 Pages
-
Data Sheet Model 9210
5 Pages
-
Flyer Load Experts
1 Pages
-
Data Sheet 8427
7 Pages
-
Displacement Sensors
2 Pages
-
Displacement Sensors
2 Pages
-
Data Sheet Typ 87240
2 Pages
-
Data sheet Typ 8416
6 Pages
-
Load cells
25 Pages
-
Data Sheet Model 8402
6 Pages
-
Flyer Load Experts
1 Pages
-
Data Sheet - Model 8438
6 Pages
-
Data Sheet Model 8400-B001
2 Pages
-
Sensor Solutions
1 Pages
-
A Connection that Networks
1 Pages
-
Qualitiy leading the way
3 Pages
-
Data Sheet Model 9250
7 Pages
-
Data Sheet Typ 8656
7 Pages
-
Data Sheet Model 9235
2 Pages
-
Data sheet Model 8435
7 Pages
-
Data Sheet Typ 8417
7 Pages
-
Data Sheet Typ 8532
2 Pages
-
Torque Sensors
9 Pages
-
Data Sheet Typ 8627
2 Pages
-
Data Sheet Model 8527
7 Pages
-
Data Sheet Model 8526
9 Pages
-
Data Sheet Model 8431
12 Pages
-
Data Sheet Typ 9311
6 Pages
-
Data Sheet Model 8511
6 Pages
-
Data Sheet - DIGISTANT® 4463
5 Pages
-
Data sheet Series 8738
2 Pages
-
Torque Sensors
16 Pages
-
Data Sheet Model 8630
6 Pages
-
Data Sheet Models 8710, 8711
2 Pages
-
Data Sheet Typ 8740/8741
4 Pages
-
Data Sheet Models 8712, 8713
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8451
7 Pages
-
Procision to the core
3 Pages
-
Flyer Battery Tester
1 Pages
-
Data Sheet Model 2560
5 Pages
-
Data Sheet Model 8561
6 Pages
-
Data Sheet Model 2311
5 Pages
-
Data Sheet Model 8523
8 Pages
-
Data Sheet Series 87350
2 Pages
-
Operation manual
76 Pages
-
Data Sheet Typ 8739
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8565
5 Pages
-
Data sheet Model 8631
5 Pages
-
Data Sheet Model 8718
2 Pages
-
Data Sheet Typ 8512
5 Pages
-
Data-Sheet- Model 8228
6 Pages
-
Data Sheet Model 8510
5 Pages
-
Data Sheet Model 8415
6 Pages
-
RESISTOMAT® Model 2329
4 Pages
-
Data Sheet Model 8524
8 Pages
-
Data Sheet Model 9186/8532
2 Pages
-
Data Sheet Typ 8645
5 Pages
-
Data sheet Model 8709
2 Pages
-
Flyer Displacement Sensor
2 Pages
-
Data Sheet - Model 8670
4 Pages