burster Battery Measuring Module AC/DC-IR measurement for 100% checking of battery cells in automation systems Protected against EM interference Highlights ■ Internal resistance ranges: 0 ... 10 to 300 mQ ■ Accuracy: from ±0,4% rdg. even with interference radiation ■ Compact design, protection class IP54 ■ Protected against electromagnetic interference ■ Measure and evaluate in a few milliseconds ■ Single to multi-channel application Options ■ Desktop device with display Areas of application ■ Quality assurance of battery cells ■ BoL, MoL assembly processes for battery modules, packs or cell-to-pack Display device Multi-channel system with top-hat rail Internal resistance measurement Effect on electrolytes detectable Internal resistance measurement Effect on electrode detectable Open circuit voltage measurement Product description The battery measurement module type 2511 is specially designed for fast, multi-channel measurement of battery cells. The device is designed for tough industrial use in highly automated systems and also for laboratory operation. The battery measurement module type 2511 offers a compact design, a high degree of protection IP54 and a design hardened against electromagnetic interference, which is essential in automated systems in order to determine measured values with maximum repeatability and traceability. The battery measuring module model 2511 performs an open circuit voltage measurement (OCV), including a detection of polarity. Using the well proven four wire measuring method, the internal resistance of the contacted cells is measured precisely. Therefore, the device combines the functionality of a battery tester and a battery analyzer and enables rapid testing of battery cells regardless of the technology. Important parameters are measured and evaluated quickly in just a few milliseconds. The testing can be carried out with individually adjustable parameters. The variable fieldbus interfaces enable flexible process integration. Fully automatic testing can be carried out in this way. Temperature measurement burster - Technical changes reserved. All data sheet at www.burster.com
Open the catalog to page 1Technical data Operating modes and measuring times galvanic isolation, inverse polarity protection, overvoltage protection (parameterization, configuration, laboratory operation) PROFINET, EtherCAT 4 rubberized feet (fitted as standard) Wall mounting (accessory only for panel mounting) Mounting rail installation (accessory, mounting rail in accordance with DIN EN 50022) * For information on other measuring times and operating modes, see operating manual F.S. = from full scale value burster - Technical changes reserved. All data sheet at www.burster.com
Open the catalog to page 2Principle of operation Battery measuring module model 2511 is optimized for rapid testing of cells. It operates in accordance with the well-tried four-conductor method (Kelvin connection) and has 4 connections for impedance measurement: 2 cables for supplying the test current and 2 cables for the voltage measurement. The battery tester works as a current sink. It draws a relatively small DC current IDC from the test object (battery cell) in relation to the load current, converts this into an AC current IAC, applies this to the test object (battery cell) and measures the resulting voltage drop...
Open the catalog to page 3Applications 16-channel high-speed application – 100 % monitoring in vehicle battery module received goods checking PLC Many battery cells are required to manufacture and install high-performance battery modules for electric vehicles. In the received goods checking area, important battery parameters of each individual cell must be reliably measured and evaluated within very short cycle times. After contacting the prismatic cells, the internal resistance with 1 kHz and the cell voltage of all 16 cells are measured and evaluated within approx. 0.5 s with the cascadable battery measuring module...
Open the catalog to page 4DigiControl PC software The innovative, intuitively operated PC software for battery measuring module 2511 is used wherever diagnoses, battery condition determination or target/actual comparisons are to be carried out on battery cells. ■ Convenient device configuration via USB interface ■ Management/configuration of different operating modes ■ Measurement data logging ■ Entry of test object designations for measurement data logging ■ Exporting the measurement data in an Excel file or as plain text ■ Evaluation of the measuring results Single cell holder Model 2500-Z001 The round cell holder enables...
Open the catalog to page 5Generate order code Standard Fieldbuses EtherCAT burster - Technical changes reserved. All data sheet at www.burster.com
Open the catalog to page 65 Pages
7 Pages
76 Pages
8 Pages
6 Pages
7 Pages
25 Pages
5 Pages
6 Pages
5 Pages
5 Pages
5 Pages
2 Pages
2 Pages
6 Pages
2 Pages
25 Pages
5 Pages
9 Pages
7 Pages
5 Pages
6 Pages
6 Pages
7 Pages
7 Pages
2 Pages
7 Pages
7 Pages
7 Pages
9 Pages
1 Page
6 Pages
6 Pages
14 Pages
2 Pages
6 Pages
5 Pages
6 Pages
7 Pages
2 Pages
2 Pages
2 Pages
7 Pages
8 Pages
7 Pages
2 Pages
2 Pages
7 Pages
5 Pages
6 Pages
7 Pages
5 Pages
2 Pages
6 Pages
5 Pages
8 Pages
9 Pages
7 Pages
6 Pages
7 Pages
7 Pages
6 Pages
6 Pages
11 Pages
2 Pages
2 Pages
1 Page
1 Page
2 Pages
2 Pages
1 Page
5 Pages
76 Pages
2 Pages
4 Pages
4 Pages
5 Pages
2 Pages
4 Pages
6 Pages