Digital Displays for Incremental Position Sensor Series 9140 ■ Display resolution from -999999 ... 999999 ■ Resolution to 0.1 ^m ■ Peak value memory for min, max and peak-to-peak ■ Classifier comparator ■ Up to 2 measuring channels ■ RS232 interface ■ Mathematical functions Application The incremental digital displays are used in combination with our high-precision displacement sensors 8738. The digital technology of these measuring systems satisfies high demands for precision and long service life, as is required more and more nowadays ► in measuring laboratories ► in production ► in testing laboratories ► in workshops and many other areas. Typical uses: ► Automatic assembly machines ► Semiconductor industry ► Keyboard tests ► Robot controllers ► Testing of shafts and planes ► Measurement of differential displacement Description With its phenomenal resolution of 0.1 pm and the high response frequency of 20 MHz, the 9140 is a powerful display unit with a compact design. The comparator function integrated as standard allows for direct evaluation of measurements almost in real-time; these can be processed further by a higher-level controller. A rather more comprehensive acquisition method is also integrated into the system. Device settings can be made either through the keypad on the front, or through the optionally available serial interface. The two-channel version also offers simple mathematical functions such as addition and subtraction. These are particularly handy for differential displacement measurements. Technical changes reserved. All data sheets at www.burster.com burster praezisionsmesstechnik gmbh & co kg Germany www.burster.com Talstr. 1-5 Gernsbach 76593 Phone +49-7224-6450 info@bursler.
Open the catalog to page 1![Data Sheet - Digital Displays for Incremental Position Sensor Series 9140 - 2](https://img.directindustry.com/pdf/repository_di/13615/data-sheet-digital-displays-incremental-position-sensor-series-9140-1067694_2m.jpg)
Technical Data Display resolution: Resolution: Cut-off frequency: Power supply: Working temperature range: Range of storage temperature: Dimensions: Panel meter (W x H x D) 10 °C ... 50 °C Front plate 72 x 72 x 104.5 [mm] +0,4 +0,4 cut-out 68+1 x 68+1 [mm] Radius, corners of cut-out Displacement indicator Standard Sensor model 8738-DK 0 8738-DG 1 Interface without 0 with RS232 1 with BCD output 2 Device type 1 channel 0 2 channel 1 Reset (via reset button, control input or RS232C command): T he display is returned to zero or to a previously entered initial value. Initial value: Any desired...
Open the catalog to page 2All Burster präzisionsmesstechnik gmbh & co kg catalogs and technical brochures
-
Press fitting - the reliable way
11 Pages
-
Data Sheet Typ 9307
6 Pages
-
Data Sheet Model 2511
6 Pages
-
Data Sheet Typ 8625
7 Pages
-
Data Sheet Model 9243
2 Pages
-
Data Sheet- Model 2500
2 Pages
-
SENSOR SOLUTIONS
1 Pages
-
A CONNECTION THAT NETWORKS
1 Pages
-
Quality leading the way
3 Pages
-
Data-Sheet - 9251
6 Pages
-
Data Sheet Model 9210
5 Pages
-
Flyer Load Experts
1 Pages
-
Data Sheet 8427
7 Pages
-
Displacement Sensors
2 Pages
-
Displacement Sensors
2 Pages
-
Data Sheet Typ 87240
2 Pages
-
Data sheet Typ 8416
6 Pages
-
Load cells
25 Pages
-
Data Sheet Model 8402
6 Pages
-
Flyer Load Experts
1 Pages
-
Data Sheet - Model 8438
6 Pages
-
Data Sheet Model 8400-B001
2 Pages
-
Sensor Solutions
1 Pages
-
A Connection that Networks
1 Pages
-
Qualitiy leading the way
3 Pages
-
Data Sheet Model 9250
7 Pages
-
Data Sheet Typ 8656
7 Pages
-
Data Sheet Model 9235
2 Pages
-
Data sheet Model 8435
7 Pages
-
Data Sheet Typ 8417
7 Pages
-
Data Sheet Typ 8532
2 Pages
-
Torque Sensors
9 Pages
-
Data Sheet Typ 8627
2 Pages
-
Data Sheet Model 8527
7 Pages
-
Data Sheet Model 8526
9 Pages
-
Data Sheet Model 8431
12 Pages
-
Data Sheet Typ 9311
6 Pages
-
Data Sheet Model 8511
6 Pages
-
Data Sheet - DIGISTANT® 4463
5 Pages
-
Data sheet Series 8738
2 Pages
-
Torque Sensors
16 Pages
-
Data Sheet Model 8630
6 Pages
-
Data Sheet Models 8710, 8711
2 Pages
-
Data Sheet Typ 8740/8741
4 Pages
-
Data Sheet Models 8712, 8713
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8451
7 Pages
-
Procision to the core
3 Pages
-
Flyer Battery Tester
1 Pages
-
Data Sheet Model 2560
5 Pages
-
Data Sheet Model 8561
6 Pages
-
Data Sheet Model 2311
5 Pages
-
Data Sheet Model 8523
8 Pages
-
Data Sheet Series 87350
2 Pages
-
Operation manual
76 Pages
-
Data Sheet Typ 8739
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8565
5 Pages
-
Data sheet Model 8631
5 Pages
-
Data Sheet Model 8718
2 Pages
-
Data Sheet Typ 8512
5 Pages
-
Data-Sheet- Model 8228
6 Pages
-
Data Sheet Model 8510
5 Pages
-
Data Sheet Model 8415
6 Pages
-
RESISTOMAT® Model 2329
4 Pages
-
Data Sheet Model 8524
8 Pages
-
Data Sheet Model 2550
4 Pages
-
Data Sheet Model 9186/8532
2 Pages
-
Data Sheet Typ 8645
5 Pages
-
Data sheet Model 8709
2 Pages
-
Flyer Displacement Sensor
2 Pages
-
Data Sheet - Model 8670
4 Pages