Data-Sheet- DIGISTANT® Model 4462-1

High Precision Calibration Source For voltage, current and thermocouples upon request Application The precision calibration unit combines high accuracy, low drift, low noise and superior long-term stability with multiple functionality and simple operation. Ramps, ∆+/∆-, and multiple setpoint storage make the operation of the device easier for the user. For that reason the application possibilities are many: High precision current and voltage source ± 52 mA, ± 30 V Option: ± 22 mA, ± 60 V Precision simulation for all conventional thermocouple types (optional) Error limit 0.003 % Rdg. Standard with RS232 and IEEE488 interface, USB and Ethernet (optional) Current "SINK" Description It is possible to set current of ± 200 nA ... ± 52 mA, voltage of ± 1 µV ... ± 30 V and, optionally temperature setpoint value of 14 thermocouples types. The output value is fed back via the sense line to eliminate voltage drops across the measuring leads. The device has an adjustable current/voltage limitation. An external voltage divider of 1 up to 1:1000 can be considered ► Precise testing of thermocouple temperature measuring internally. instruments With the thermovoltage sourcing option you can enter °C, °F and K, the temperature scales ITS 90 or IPTS 68 and the ► Calibration of controllers, sensors, detection devices and comparison point mode constant/external. Furthermore, when other devices used in process control sourcing thermocouples a calibrated external comparison ► Open-loop process control with the aid of integrated point can be used, whereby the data for calibration in the ramp function device can be taken into consideration. DIGISTANT® model 4462 can be used both as a stand-alone Indication of the source value is carried out in large 12 mm table-top device, as well as in automatic, computer-assisted figures on an illuminated graphics-LCD. manufacturing and testing systems. The device can be operated both via the keyboard as well as the interface. ► Calibration of current and DC-voltage meters Technical changes reserved Latest updates of data sheet always under www.burster.com burster praezisionsmesstechnik gmbh & co kg . Tel. +49-7224-6450 . Fax 64588 Talstr. 1-5 . DE-76593 Gernsbach . www.burster.

 Open the catalog to page 1
Data-Sheet- DIGISTANT® Model 4462-2

Source main menu External sense Divider factor of the external divider. The voltage value is fed with the value which should appear on the output. Manual range selection Current limitation A new delta value can be entered Currently set delta value Source value Source value will be negative 0 are edited. The last source value remains stored Source value will be positive Operating Examples Ramp 1 Configuration menu SEQUENZ: TRIANGEL REPETITIONS: 17 START-VAL: 0.0mV END-VAL: 250.0mV DELTA-VAL: 25.0mV DELTA-TIME.hh:mm:ss.s Ramp function: ► Ramp 1 with constant delta values and delta time ► Ramp 2...

 Open the catalog to page 2
Data-Sheet- DIGISTANT® Model 4462-3

Technical Data Voltage source Resolution Error limits at 23 °C ± of reading Option: 60 V (Range 30 V will be dropped) Range ± Error limits at 23 °C ± of reading Output current: Current source Error limits at 23 °C ± of reading Burden voltage: max 30 V at 52 mA, source resistance > 500 MΩ Confidence coefficient for the specified errors: 95 % (K2). (Burden voltage: max 60 V at 22 mA, model VXX1) Option: Thermocouple simulation Model Relative humidity: 80 % up to 31 °C above linear: decreasing that temperature to 50 % at Tmax, no condensation Storage temperature: - 10 °C ... 60 °C Device construction:...

 Open the catalog to page 3
Data-Sheet- DIGISTANT® Model 4462-4

External reference junction model 4485-V001 for thermocouples ► ► ► ► For an accurate simulation of thermocouples A built-in Pt100 for cold junction compensation Thermally stable and isolated construction Plug type: Miniature TC connector Technical Data ► Limits: ► Long term stability: ► Insulation resistance between pins in disconnected status: ► Operating temperature range: ► Storage temperature range: Thermo cable and connector cause an additional error. We recommend to use the class 1. Application Example 1. Calibration of a PC card with a thermocouple measurement input Instead of the thermocouple...

 Open the catalog to page 4