Catalog excerpts
![Data sheet - DIGILOW Digital indicator for strain gauge sensors Model 9186 - 1](https://img.directindustry.com/pdf/repository_di/13615/data-sheet-digilow-digital-indicator-strain-gauge-sensors-model-9186-1067448_1m.jpg)
DIGILOW Digital indicator for strain gauge sensors Model 9186 Code: 9186 EN Desktop version ■ Less expensive digital display ■ For force, pressure or torque measurements using gauge sensors ■ Two limit alarms optionally available ■ Extremely easy-to-read display with 20 mm digit height ■ Display range -1999 to + 9999 ■ TARE function ■ Scaling possible using teach-in procedure or by entering sensor data directly Application The DIGILOW digital display can be used with strain gauge sensors measuring force, pressure or torque. The range of functions has been limited deliberately to ensure operation is simple and self-explanatory. With its unique, large and clear digit height of 20 mm, the digital display can be installed easily in process control panels and control cabinets. Thanks to the large choice of measurement signals that can be indicated, the display is ideal for use in a huge range of industry-based applications. As a simple and compact digital display, it can also be used as a multi-channel solution in laboratory or test systems, where several different measurements may need to be taken and displayed simultaneously. The front panel TARE function for the strain gauge sensor input makes it easy to zero the display for processes where an initial load may be applied (containers’ own weight, pre-tensioning of sensor by tool adaptation and so on). Production-oriented evaluation and control functions can be implemented using the limit generation option. Description The production of this excellent value digital display was possible by employing state-of-the-art microprocessor technology and keeping the complexity of the internal design to a minimum. The simple menu-driven instrument setup procedure with self-explanatory mnemonics ensures that even the novice can use the unit immediately without an operating manual. First, the user specifies the type of input signal or sensor. Then the user can select the relevant calibration procedure by either applying an input meas-surement or through teach-in (calibration taken from sensor documentation). The position of the decimal point can be set to suit, while the sensor supply voltage can be hardware-set to 5 VDC (default) or 10 VDC. There is also the option to use a digital low-pass filter to correct any display flicker caused by the particular application. Technical changes reserved. All data sheets at www.burster.com burster praezisionsmesstechnik gmbh & co kg Germany www.burster.com Talstr. 1-5 Gernsbach 76593 Phone +49-7224-6450 info@bursler.com
Open the catalog to page 1![Data sheet - DIGILOW Digital indicator for strain gauge sensors Model 9186 - 2](https://img.directindustry.com/pdf/repository_di/13615/data-sheet-digilow-digital-indicator-strain-gauge-sensors-model-9186-1067448_2m.jpg)
16 bit 0.1 % v. E. ± 4 digits 100 ppm/K 10 minutes - 1999 ... + 9999, height 20 mm 250 ms 25/sec. - 10 ... + 60 °C 95 % at 40 °C Front panel IP65 96 x 48 x 60 [mm] approx. 90 mm 92 x 44 [mm] 250 g plastic 130 x 70 x 150 [mm] 250 g Plastic Technical Data Connectable sensors Strain gauge Connection system: 4 wire Bridge voltage: 30 mV / 300 mV / selection via menu Standard functions TARE Balancing-out an offset Digital control input TARE General specifications Accuracy Resolution: Measurement error: Temperature coefficient: Warm-up period: Display Display: Display timing: Measurement range...
Open the catalog to page 2All Burster präzisionsmesstechnik gmbh & co kg catalogs and technical brochures
-
Press fitting - the reliable way
11 Pages
-
Data Sheet Typ 9307
6 Pages
-
Data Sheet Model 2511
6 Pages
-
Data Sheet Typ 8625
7 Pages
-
Data Sheet Model 9243
2 Pages
-
Data Sheet- Model 2500
2 Pages
-
SENSOR SOLUTIONS
1 Pages
-
A CONNECTION THAT NETWORKS
1 Pages
-
Quality leading the way
3 Pages
-
Data-Sheet - 9251
6 Pages
-
Data Sheet Model 9210
5 Pages
-
Flyer Load Experts
1 Pages
-
Data Sheet 8427
7 Pages
-
Displacement Sensors
2 Pages
-
Displacement Sensors
2 Pages
-
Data Sheet Typ 87240
2 Pages
-
Data sheet Typ 8416
6 Pages
-
Load cells
25 Pages
-
Data Sheet Model 8402
6 Pages
-
Flyer Load Experts
1 Pages
-
Data Sheet - Model 8438
6 Pages
-
Data Sheet Model 8400-B001
2 Pages
-
Sensor Solutions
1 Pages
-
A Connection that Networks
1 Pages
-
Qualitiy leading the way
3 Pages
-
Data Sheet Model 9250
7 Pages
-
Data Sheet Typ 8656
7 Pages
-
Data Sheet Model 9235
2 Pages
-
Data sheet Model 8435
7 Pages
-
Data Sheet Typ 8417
7 Pages
-
Data Sheet Typ 8532
2 Pages
-
Torque Sensors
9 Pages
-
Data Sheet Typ 8627
2 Pages
-
Data Sheet Model 8527
7 Pages
-
Data Sheet Model 8526
9 Pages
-
Data Sheet Model 8431
12 Pages
-
Data Sheet Typ 9311
6 Pages
-
Data Sheet Model 8511
6 Pages
-
Data Sheet - DIGISTANT® 4463
5 Pages
-
Data sheet Series 8738
2 Pages
-
Torque Sensors
16 Pages
-
Data Sheet Model 8630
6 Pages
-
Data Sheet Models 8710, 8711
2 Pages
-
Data Sheet Typ 8740/8741
4 Pages
-
Data Sheet Models 8712, 8713
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8451
7 Pages
-
Procision to the core
3 Pages
-
Flyer Battery Tester
1 Pages
-
Data Sheet Model 2560
5 Pages
-
Data Sheet Model 8561
6 Pages
-
Data Sheet Model 2311
5 Pages
-
Data Sheet Model 8523
8 Pages
-
Data Sheet Series 87350
2 Pages
-
Operation manual
76 Pages
-
Data Sheet Typ 8739
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8565
5 Pages
-
Data sheet Model 8631
5 Pages
-
Data Sheet Model 8718
2 Pages
-
Data Sheet Typ 8512
5 Pages
-
Data-Sheet- Model 8228
6 Pages
-
Data Sheet Model 8510
5 Pages
-
Data Sheet Model 8415
6 Pages
-
RESISTOMAT® Model 2329
4 Pages
-
Data Sheet Model 8524
8 Pages
-
Data Sheet Model 2550
4 Pages
-
Data Sheet Model 9186/8532
2 Pages
-
Data Sheet Typ 8645
5 Pages
-
Data sheet Model 8709
2 Pages
-
Flyer Displacement Sensor
2 Pages
-
Data Sheet - Model 8670
4 Pages