Catalog excerpts
![Data sheet - Calibration Resistor Modelserie 1240 - 1](https://img.directindustry.com/pdf/repository_di/13615/data-sheet-calibration-resistor-modelserie-1240-1062352_1m.jpg)
Calibration Resistor te ertifica With C ISO 9000 ing to accord Application The 0.02 class calibration resistors excel in their modern design and small mechanical dimensions. Their ruggedness also ensures a long life. Calibration resistors of the 1240 series are used wherever very constant operating standards are required. Typical main areas of application therefore include: ► When normal resistors prove to be too large scale ► For test and calibration of resistance measurement devices ► For tests on electrical temperature measuring equipment ► For laboratory setup of a Wheatstone bridge ► As shunt resistor for accurate current measurement ► As part of standard equipment in research laboratories ► For a large part of measurements in calibration laboratory A test certificate according to ISO 9000 with detailed technical data is included in the scope of delivery of these high-quality calibration resistors. Technical changes reserved. All data sheets at www.burster.com Range 10 µΩ ... 100 kΩ Low capacitance and low inductance design Suitable for direct current and technical frequencies High stability < ± 0.01 % over years DAkkS Calibration Certificate The calibration laboratory D-K-15141-01-00 at burster praezisionsmesstechnik is supervised by DAkkS (Deutsche Akkreditierungsstelle GmbH) according to ISO 17025. It can prove its status by a certificate and is authorized to issue calibration certificates with the DAkkS logo and with the DKD logo (Deutscher Kalibrierdienst). These calibration certificates are internationally approved by multilateral contracts. Manufacturer Calibration Certificate Please refer to DAkkS Calibration Certificate but with reduced accuracy. The calibration resistors can also be delivered with a manufacturer calibration certificate. It confirms the traceability of the used secondary voltage and resistance standards to the national standards according to DIN ISO 9000ff and is guaranteed by our certified calibration laboratory (D-K-15141-01-00). burster praezisionsmesstechnik gmbh & co kg Germany www.burster.com Talstr. 1-5 . Gernsbach 76593 . Phone +49-7224-6
Open the catalog to page 1![Data sheet - Calibration Resistor Modelserie 1240 - 2](https://img.directindustry.com/pdf/repository_di/13615/data-sheet-calibration-resistor-modelserie-1240-1062352_2m.jpg)
1240 EN - 2 Technical Data Resistance material: Temperature coefficient: Temperature dependence: Calibration temperature: Surface temperature (To ): Thermal resistance (Rth): Operation temperature (Tu): Increase of temperature: Surface temperature: Test voltage: Nominal insulation voltage: 10 pQ ... 200 mQ MANGANIN® sheet 500 mQ ... 100 kQ MANGANIN® wire approx.± 10 ppm/K (1 + a20 (t - 20) + b (t - 20)2) 10-6 b = - 0.59.10-6 23 °C ± 3 K (< 0.5 W load) max. 85 °C 11 K/W 0 ... 23 ... 40 °C Tp = Rth . I2 . (R + Rl) To = Tu + Tp (To = 85 °C) max 2900 VDC (resistance element housing) 650 VDC...
Open the catalog to page 2All Burster präzisionsmesstechnik gmbh & co kg catalogs and technical brochures
-
Press fitting - the reliable way
11 Pages
-
Data Sheet Typ 9307
6 Pages
-
Data Sheet Model 2511
6 Pages
-
Data Sheet Typ 8625
7 Pages
-
Data Sheet Model 9243
2 Pages
-
Data Sheet- Model 2500
2 Pages
-
SENSOR SOLUTIONS
1 Pages
-
A CONNECTION THAT NETWORKS
1 Pages
-
Quality leading the way
3 Pages
-
Data-Sheet - 9251
6 Pages
-
Data Sheet Model 9210
5 Pages
-
Flyer Load Experts
1 Pages
-
Data Sheet 8427
7 Pages
-
Displacement Sensors
2 Pages
-
Displacement Sensors
2 Pages
-
Data Sheet Typ 87240
2 Pages
-
Data sheet Typ 8416
6 Pages
-
Load cells
25 Pages
-
Data Sheet Model 8402
6 Pages
-
Flyer Load Experts
1 Pages
-
Data Sheet - Model 8438
6 Pages
-
Data Sheet Model 8400-B001
2 Pages
-
Sensor Solutions
1 Pages
-
A Connection that Networks
1 Pages
-
Qualitiy leading the way
3 Pages
-
Data Sheet Model 9250
7 Pages
-
Data Sheet Typ 8656
7 Pages
-
Data Sheet Model 9235
2 Pages
-
Data sheet Model 8435
7 Pages
-
Data Sheet Typ 8417
7 Pages
-
Data Sheet Typ 8532
2 Pages
-
Torque Sensors
9 Pages
-
Data Sheet Typ 8627
2 Pages
-
Data Sheet Model 8527
7 Pages
-
Data Sheet Model 8526
9 Pages
-
Data Sheet Model 8431
12 Pages
-
Data Sheet Typ 9311
6 Pages
-
Data Sheet Model 8511
6 Pages
-
Data Sheet - DIGISTANT® 4463
5 Pages
-
Data sheet Series 8738
2 Pages
-
Torque Sensors
16 Pages
-
Data Sheet Model 8630
6 Pages
-
Data Sheet Models 8710, 8711
2 Pages
-
Data Sheet Typ 8740/8741
4 Pages
-
Data Sheet Models 8712, 8713
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8451
7 Pages
-
Procision to the core
3 Pages
-
Flyer Battery Tester
1 Pages
-
Data Sheet Model 2560
5 Pages
-
Data Sheet Model 8561
6 Pages
-
Data Sheet Model 2311
5 Pages
-
Data Sheet Model 8523
8 Pages
-
Data Sheet Series 87350
2 Pages
-
Operation manual
76 Pages
-
Data Sheet Typ 8739
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8565
5 Pages
-
Data sheet Model 8631
5 Pages
-
Data Sheet Model 8718
2 Pages
-
Data Sheet Typ 8512
5 Pages
-
Data-Sheet- Model 8228
6 Pages
-
Data Sheet Model 8510
5 Pages
-
Data Sheet Model 8415
6 Pages
-
RESISTOMAT® Model 2329
4 Pages
-
Data Sheet Model 8524
8 Pages
-
Data Sheet Model 2550
4 Pages
-
Data Sheet Model 9186/8532
2 Pages
-
Data Sheet Typ 8645
5 Pages
-
Data sheet Model 8709
2 Pages
-
Flyer Displacement Sensor
2 Pages
-
Data Sheet - Model 8670
4 Pages