Catalog excerpts
![Data-Sheet - 9251 - 1](https://img.directindustry.com/pdf/repository_di/13615/data-sheet-9251-1070800_1m.jpg)
Delivery: on request | Warranty: 24 months Fieldbus Controller for the 9250 Instrumentation Amplifier series Highlights ■ NEW: Measuring input: Strain gage, Potentiometer, ±10 V ■ Non-linearity < 0,005 % F.S. ■ TARA function with LED display ■ PROFINET, EtherCAT and EtherNet/IP ■ High measurement speed ■ Up to 8 model 9250 instrumentation amplifiers can be modularly connected Applications Automation technology Production Research and development Mechanical engineering Test-bench equipment NEW 9251 with integrated strain gage measuring input EtherCAT.^ Product description The new 9250/9251 amplifier generation unites all the features that make modern measurement data acquisition actually possible for the first time. Network-compatible, high-precision, user-friendly, smart and versatile: the combined system of amplifier module and Fieldbus controller can be integrated into any existing setup. The Fieldbus controller delivers all signals exactly where they are needed, to be combined, checked and linked. With the available Fieldbus interfaces, you are flexible, perfectly connected and you save time, costs and other resources when linking to and integrating into existing systems. Due to the integrated measuring input, the use of a Fieldbus controller module is sufficient for single-channel applications. For multi-channel applications, the system can be expanded to up to 9 measuring channels. Fieldbus controller 9251 with up to 8 instrumentation Up to 8 bus-compatible model 9250 instrumentation amplifiers can be cascaded on the model 9251 Fieldbus controller. Automatic detection 9250 and addressing of the instrumentation amplifier modules allows easy expansion. By means of measuring input, the fieldbus controller can be operated as a stand-alone device. Some applications require large amounts of measurement data to be acquired and transmitted within a very short time. Very fast PLC communication with high update rates is needed. To optimize data throughput, the model 9251 Fieldbus controller can transmit a whole data array with the last 32 measured values per channel. The scaled measured values are read simultaneously in the real-time data of the Fieldbus link. burster Sensors and Process Instruments - Technical changes reserved. All data sheets at www.burster.com
Open the catalog to page 1![Data-Sheet - 9251 - 2](https://img.directindustry.com/pdf/repository_di/13615/data-sheet-9251-1070800_2m.jpg)
burster Sensors and Process Instruments - Technical changes reserved. All data sheets at www.burster.com
Open the catalog to page 2![Data-Sheet - 9251 - 3](https://img.directindustry.com/pdf/repository_di/13615/data-sheet-9251-1070800_3m.jpg)
burster Sensors and Process Instruments - Technical changes reserved. All data sheets at www.burster.com
Open the catalog to page 3![Data-Sheet - 9251 - 4](https://img.directindustry.com/pdf/repository_di/13615/data-sheet-9251-1070800_4m.jpg)
Block diagram – singlechannel application, fieldbus controller with measuring input and load cell Fieldbus controller Galvanic isolation USB interface Config / status Block diagram – multichannel application with universal instrumentation amplifier, fieldbus controller with measuring input and load cells Fieldbus controller Galvanic isolation Config / status burster Sensors and Process Instruments – Technical changes reserved. All data sheets at www.burster.com
Open the catalog to page 4![Data-Sheet - 9251 - 5](https://img.directindustry.com/pdf/repository_di/13615/data-sheet-9251-1070800_5m.jpg)
DigiVision PC software Free of charge at www.burster.com Convenient device configuration via front-panel USB port Automatic recognition of amplifier modules in DigiVision Backup facility for storing settings Analog output configuration Scaling of output values Configuration of PLC I/O outputs Device information burster Sensors and Process Instruments - Technical changes reserved. All data sheets at www.burster.com
Open the catalog to page 5![Data-Sheet - 9251 - 6](https://img.directindustry.com/pdf/repository_di/13615/data-sheet-9251-1070800_6m.jpg)
Calibration certificates for measurement chains burster Sensors and Process Instruments - Technical changes reserved. All data sheets at www.burster.com
Open the catalog to page 6All Burster präzisionsmesstechnik gmbh & co kg catalogs and technical brochures
-
Press fitting - the reliable way
11 Pages
-
Data Sheet Typ 9307
6 Pages
-
Data Sheet Model 2511
6 Pages
-
Data Sheet Typ 8625
7 Pages
-
Data Sheet Model 9243
2 Pages
-
Data Sheet- Model 2500
2 Pages
-
SENSOR SOLUTIONS
1 Pages
-
A CONNECTION THAT NETWORKS
1 Pages
-
Quality leading the way
3 Pages
-
Data Sheet Model 9210
5 Pages
-
Flyer Load Experts
1 Pages
-
Data Sheet 8427
7 Pages
-
Displacement Sensors
2 Pages
-
Displacement Sensors
2 Pages
-
Data Sheet Typ 87240
2 Pages
-
Data sheet Typ 8416
6 Pages
-
Load cells
25 Pages
-
Data Sheet Model 8402
6 Pages
-
Flyer Load Experts
1 Pages
-
Data Sheet - Model 8438
6 Pages
-
Data Sheet Model 8400-B001
2 Pages
-
Sensor Solutions
1 Pages
-
A Connection that Networks
1 Pages
-
Qualitiy leading the way
3 Pages
-
Data Sheet Model 9250
7 Pages
-
Data Sheet Typ 8656
7 Pages
-
Data Sheet Model 9235
2 Pages
-
Data sheet Model 8435
7 Pages
-
Data Sheet Typ 8417
7 Pages
-
Data Sheet Typ 8532
2 Pages
-
Torque Sensors
9 Pages
-
Data Sheet Typ 8627
2 Pages
-
Data Sheet Model 8527
7 Pages
-
Data Sheet Model 8526
9 Pages
-
Data Sheet Model 8431
12 Pages
-
Data Sheet Typ 9311
6 Pages
-
Data Sheet Model 8511
6 Pages
-
Data Sheet - DIGISTANT® 4463
5 Pages
-
Data sheet Series 8738
2 Pages
-
Torque Sensors
16 Pages
-
Data Sheet Model 8630
6 Pages
-
Data Sheet Models 8710, 8711
2 Pages
-
Data Sheet Typ 8740/8741
4 Pages
-
Data Sheet Models 8712, 8713
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8451
7 Pages
-
Procision to the core
3 Pages
-
Flyer Battery Tester
1 Pages
-
Data Sheet Model 2560
5 Pages
-
Data Sheet Model 8561
6 Pages
-
Data Sheet Model 2311
5 Pages
-
Data Sheet Model 8523
8 Pages
-
Data Sheet Series 87350
2 Pages
-
Operation manual
76 Pages
-
Data Sheet Typ 8739
2 Pages
-
Load-cell
25 Pages
-
Data Sheet Motel 8565
5 Pages
-
Data sheet Model 8631
5 Pages
-
Data Sheet Model 8718
2 Pages
-
Data Sheet Typ 8512
5 Pages
-
Data-Sheet- Model 8228
6 Pages
-
Data Sheet Model 8510
5 Pages
-
Data Sheet Model 8415
6 Pages
-
RESISTOMAT® Model 2329
4 Pages
-
Data Sheet Model 8524
8 Pages
-
Data Sheet Model 2550
4 Pages
-
Data Sheet Model 9186/8532
2 Pages
-
Data Sheet Typ 8645
5 Pages
-
Data sheet Model 8709
2 Pages
-
Flyer Displacement Sensor
2 Pages
-
Data Sheet - Model 8670
4 Pages