  3. Operation Manual Milliohmmeter RESISTOMAT® Model 2316

Operation Manual Milliohmmeter RESISTOMAT® Model 2316

Operation Manual Milliohmmeter RESISTOMAT® Model 2316
1 / 124 PagesView full catalog

Operation Manual Milliohmmeter RESISTOMAT® Model 2316

Product catalog summary
Introduction
The document is an operation manual for the Milliohmmeter RESISTOMAT® Model 2316, intended for both production and laboratory environments. It provides comprehensive instructions on setup, operation, and maintenance.
Safety Instructions
This section details the symbols and signal words used to ensure safe operation, emphasizing adherence to guidelines to prevent accidents and equipment damage.
Specifications and Compliance
The RESISTOMAT® Model 2316 complies with EU directives on hazardous substances, voltage limits, and electromagnetic compatibility, meeting EN 61010-1 and EN 61326-1 standards.
Setup and Installation
Instructions cover unpacking, initial setup, and installation, including supply voltage, power connections, and calibration procedures, supported by a block diagram.
Controls and Interfaces
The manual describes the front and rear panel controls, button functions, and connector sockets, along with interfaces for remote control such as RS232, USB, and Ethernet.
Operation
Detailed instructions include display segments, configuration menus, and measurement modes, with guidance on handling different load types and performing temperature compensation.
Remote Control and SCPI Commands
Guidance is provided for remote control via PLC, RS232, and Ethernet interfaces, along with a comprehensive list of SCPI commands for advanced programming and automation.
Warranty and Liability
The manufacturer offers a warranty for material and production defects, excluding liability for improper use or consequential damages, advising users to follow the manual closely.
Installation and Handling Instructions
Recommendations include using the instrument in a horizontal position, avoiding extreme conditions, and using protective enclosures in dirty environments.
Functional Test and Calibration
The instrument is pre-calibrated and should be recalibrated annually, preferably at the manufacturer's premises.
Storage Guidelines
Store the unit in an airtight bag with a desiccant, away from light sources, and protect the display panel.
Safety Instructions
Precautions include not using the instrument for life-risk systems without protection, ensuring no external voltage before measurement, and handling inductive devices carefully.
Control Panel and Interfaces
The front panel features a backlit LCD display and a membrane keypad, with detailed instructions for safe connections to various interfaces.
Operating Instructions
The configuration menu allows setting adjustments, and the measurement menu displays current status with options for manual or automatic range selection.
Limits
Instructions for setting measurement limits are provided, with activation of PLC outputs or relays based on evaluation results.
Load Selection
Users can select time constants for the current regulator, with safety warnings for handling inductive loads.
Protection Circuit
The instrument includes a protection circuit with a fuse and overvoltage arrester, designed for up to 400 Vrms.
Measurement Modes
Several modes are described, including continuous operation, single shot, alternating measurement, fast measure, and cooling curve, each with specific settings and limitations.
Measurement Procedures
The instrument records resistance values over time, with options for temperature compensation and autozero functions.
Device Programming
Users can copy and initialize device programs, with options for comparator settings and display adjustments.
Self-Diagnostic Tests
Built-in tests help verify instrument functionality and troubleshoot issues.
Access Control
Access to settings can be restricted with a password, with options for changing it.
Interfaces
Details on RS232, USB, Ethernet, and Printer interfaces are provided, with specific configuration settings.
Reference Settings
Instructions for setting reference temperature and length are included, affecting calibration status.
Measurement Current Selection
Options for low and high measurement currents are provided, with recommendations based on the environment.
Calibration
Digital calibration requires specific software and calibration resistances.
Remote Control
Control via PLC and RS232 interfaces is described, including pin configurations and communication protocols.
Communication Protocol
Specifications for control characters and protocol standards are provided, emphasizing ANSI standard X3.28-1976.
Connection Establishment
Methods for establishing connections include "selection with response" and "fast selection," with examples provided.
SCPI Commands
Commands have optional sections, long and short forms, with specific formatting rules.
Changes in Functions
Some functions have changed from previous models, with recommendations to avoid outdated commands.
Specifications
Details on resistance measurement, comparator limits, display, and access settings are provided.
Procedures
Calibration and data handling procedures are outlined, with configurable Pt100 coefficients for temperature scaling.
Standards and Compliance
SCPI registers and IEEE488.2 compliance are detailed, with specific bits indicating errors or valid measurements.
Recommendations
Ensure commands are not executed during calibration or active measurements to avoid errors.
Limitations
Some commands are not implemented and return errors, with unsupported functions noted.
Trigger Subsystem
Commands for starting, stopping, and switching measurement modes are detailed.
System Subsystem
Commands for querying system version, language, and errors are provided.
Status Subsystem
Commands for resetting and querying status registers are included.
Sense Subsystem
Commands for temperature compensation and measurement resolution are detailed.
Automatic and Manual Range Selection
Instructions for setting measurement ranges and offset correction are provided.
Source Subsystem
Commands for setting measurement current are included.
IEEE-488.2 Commands
Standard commands for service request, status byte, and device identification are detailed.
Programming Examples
Examples for communication using "selection with response" and "fast selection" modes are provided.
Maintenance and Customer Service
No user maintenance is required, with annual recalibration recommended. Contact details for customer service are provided.
Technical Data
Technical specifications include display features, measurement accuracy, and operational parameters.
Calibration and Adjustment
Calibration involves specific software and resistances, with digital adjustment processes.
Error Messages and Troubleshooting
Error messages and troubleshooting tips are provided, with specific error codes.
Disposal
Instructions for proper disposal of batteries and equipment are included, emphasizing legal and environmental obligations.
See more

Catalog excerpts

Operation Manual Milliohmmeter RESISTOMAT® Model 2316-1

OPERATION MANUALMilliohmmeter RESISTOMAT® Model 2316 Manufacturer: burster praezisionsmesstechnik gmbh & co kg burster Talstr. 1 - 5 P.O.Box 1432 praezisionsmesstechnik gmbh & co kg 76593 Gernsbach 76587 Gernsbach All rights reserved Germany Germany Software version V 201801 Valid from: 04.03.2024 Email: [email protected]

 Open the catalog to page 1
Operation Manual Milliohmmeter RESISTOMAT® Model 2316-2

Exclusion of warranty liability for operating manuals All information in the present documentation was prepared and compiled with great care and reproduced subject to effective control measures. No warranty is provided for freedom from errors. We reserve the right to make technical changes. The present information as well as the corresponding technical data can change without notice. Reproduction of any part of this documentation or its processing or revision using electronic systems is prohibited without the manufacturer’s prior written approval. Components, devices and measured value sensors...

 Open the catalog to page 2
Operation Manual Milliohmmeter RESISTOMAT® Model 2316-3

RESISTOMAT® Model 2316The measurement solution.EU-Konformitatserklarung (nach en iso/iec 17050-1:2010) EU-Declaration of conformity (in accordance with EN ISO/IEC 17050-1:2010) Name des Ausstellers: burster prazisionsmesstechnik gmbh & co kg Issuer’s name: Anschrift des Ausstellers: Talstr. 1-5 Issuer’s address: 76593 Gernsbach, Germany Gegenstand der Erklarung: Milliohmmeter RESISTOMAT® fur Fertigung und Labor Object of the declaration: Milliohmmeter RESISTOMAT® for Production and Laboratory Model number / type: Diese Erklarung beinhaltet obengenannte Produkte mit alien Optionen This declaration...

 Open the catalog to page 3
Operation Manual Milliohmmeter RESISTOMAT® Model 2316-4

6.5.3.1 Handling inductive loads e.g. reactors, cables on reels, motors,

 Open the catalog to page 4
Operation Manual Milliohmmeter RESISTOMAT® Model 2316-9

RESISTOMAT® Model 2316 1 Safety instructions On the device RESISTOMAT® 2316 and in this manual the following symbols warn about risks: The following signal words are used in the operating manual according to the specified hazard classification. DANGER indicates a hazard with a high level of risk which, if not avoided, will result in death or serious injury. WARNING indicates a hazard with a medium level of risk which, if not avoided, could result in death or serious injury. CAUTION indicates a hazard with a low level or risk which, if not avoided, could result in minor or moderate injury. Property...

 Open the catalog to page 9
Operation Manual Milliohmmeter RESISTOMAT® Model 2316-10

RESISTOMAT® Model 23162 Introduction IMPORTANT: Read the operation manual carefully before using the equipment, and keep for future reference. Fast and accurate measurements of ultra-small resistances can be made using the RESISTOMAT® type 2316 milliohmmeter. With its rugged table-top case and membrane keypad, this instrument is designed for both laboratory use and harsh industrial environments. Temperature-compensated resistance-testing of wires and coils is possible using a Pt 100 sensor or pyrometer to measure the temperature of the device under test. The instrument then corrects the resistance...

 Open the catalog to page 10
Operation Manual Milliohmmeter RESISTOMAT® Model 2316-11

The instrument weighs 3.5 kg and is packaged accordingly to protect against shock. Unpack the instrument carefully and verify that all items are present. This normally includes: 1 RESISTOMAT® model 2316 milliohmmeter 1 power lead 1 copy of this manual Inspect the instrument carefully for damage. If you suspect that the instrument has been damaged during shipping, notify the delivery company immediately. The packaging should be retained for examination by a representative of the manufacturer and/or the delivery company. The RESISTOMAT® model 2316 should be shipped only in its original packaging...

 Open the catalog to page 11
Operation Manual Milliohmmeter RESISTOMAT® Model 2316-12

Power supply and signal-lead connectors USB interface Measurement input either via 5-pin bayonet socket or 4x laboratory safety sockets (4mm ø) Mains fuse Ethernet interface Power switch Mains socket RS232 interface IMPORTANT: additional protection of the measurement current using a super quick-acting 10 A fuse 6.3 x 32 mm, 600 VAC, 50 kA breaking capacity (or greater) RS Components #209-9406 (in Germany) Only use this fuse NOTICE • Use a suitable connecting cable with a dual-shield construction (aluminum foil cladding plus braided shield) for the communications port connection and the PLC I/O...

 Open the catalog to page 12
Operation Manual Milliohmmeter RESISTOMAT® Model 2316-13

RESISTOMAT® Model 2316Block diagram c <D .Q

 Open the catalog to page 13
Operation Manual Milliohmmeter RESISTOMAT® Model 2316-14

RESISTOMAT® Model 23163.6 Setup and installation • Ensure that there is an adequate supply of air to prevent heat building up in the instrument. • Do not place the instrument on surfaces such as carpets or cloths, or near materials such as curtains or wall hangings that could prevent the air circulating. • Do not place the instrument at an inclined angle. It should always be used in a horizontal position. • Keep the instrument away from apparatus, equipment, machines and installations that generate strong magnetic fields. • Do not place heavy objects on the instrument. • Condensation can form...

 Open the catalog to page 14
Operation Manual Milliohmmeter RESISTOMAT® Model 2316-15

RESISTOMAT® Model 2316 3.10 Safety instructions A DANGER Whilst the hardware and software has been developed and tested in accordance with the state of the art, they cannot be guaranteed totally free of errors. Thus this instrument or part of this instrument must not be used to influence a control system from which risk to life or property can arise directly or indirectly without additional protection. Maintenance and repair work must only be performed by trained, competent technical personnel familiar with the associated risks. • The instrument has two measurement inputs connected in parallel;...

 Open the catalog to page 15
Operation Manual Milliohmmeter RESISTOMAT® Model 2316-16

4 Controls 4.1 Front panel Front panel with backlit LCD display and integral membrane keypad with tactile feedback [START] : In the measurement menu this button starts a measurement In the Configuration menu this button is assigned different functions depending on the text shown on the display above the button (soft key). [STOP] : In the measurement menu this button stops a measurement. In the Configuration menu this button is assigned different functions depending on the text shown on the display above the button (soft key). [ft] : In the measurement menu and for manual range-selection can be...

 Open the catalog to page 16