Operation Manual Instrumentation Amplifier Model 9250

Product catalog summary
Warranty Disclaimer: The document outlines a warranty covering material and production defects of the products, excluding liability for consequential damages from improper use and does not guarantee market success or suitability for specific purposes.
Contents Overview: The manual is organized into sections including safety instructions, device design, controls and connections, initial use, configuration, calibration, and customer services.
1. Safety Instructions: This section explains the symbols and conventions used to ensure user safety and proper handling of the device, using signal words like DANGER, WARNING, CAUTION, and NOTICE.
2. Introduction: Describes the intended industrial use of the 9250 instrumentation amplifier, suitable for EMC-certified control cabinets, and provides customer service contact information.
3. Device Design: Details the amplifier's functions, signal processing, measurement quality, model versions, power supply, and compatible sensors.
4. Controls and Connections: Explains the controls, including LEDs, control buttons, grounding, shielding, compatible sensors, and outputs.
5. Initial Use: Provides installation and removal instructions for the instrument.
6. Configuration: Offers guidance on manual and software-based configuration, including input selection and analog output configuration.
7. Calibration: Describes the calibration process for different sensor types, including strain-gage and potentiometric sensors.
8. Customer Services: Information on available customer services for the 9250 instrumentation amplifier.
9. Technical Data: Includes specifications related to electromagnetic compatibility and interference immunity.
LED Indicators: The device features LEDs indicating the status of PLC outputs, analog output modes, input configurations, and tare status.
Control Buttons: Includes buttons for taring, input configuration, and output selection, with specific functions for each.
Grounding and Shielding: Proper grounding via the mounting rail is essential, with recommendations for sensor leads and system components.
Compatible Sensors/Inputs: Supports various sensor types with specific configuration options and requirements.
Outputs: Offers configurable analog voltage and current outputs, with only one active and calibrated at a time.
PLC Inputs/Outputs: Separate PLC inputs and outputs for various functions, isolated from the instrumentation electronics.
Burster TEDS Support: The amplifier can read burster TEDS data for automatic sensor configuration.
Connections: Detailed terminal assignments for connecting various sensor types, with diagrams illustrating connection methods.
Installation and Safety: The amplifier must be installed on a grounded mounting rail in a control cabinet, with safety warnings highlighted.
Configuration: Quick configuration via manual button operations, with detailed steps for selecting input and output options.
Performing Sensor Teach-In: Instructions for activating calibration mode and setting analog output levels.
Tare Function: Corrects static offsets on sensor channels, with instructions for activation and deactivation.
Additional Settings via DigiVision: System requirements and software installation instructions for DigiVision, used for device detection and configuration.
Device Settings: Includes measurement mode, decimal places, unit settings, sensor excitation voltage, filter options, and samples per second.
Configuring the Analog Output: Instructions for configuring voltage and current outputs.
Configuring PLC I/O - Digital Inputs / Limits: Configuration options for dynamic and static limit settings.
Device Settings - Properties: Includes station name, calibration date, software version, serial number, and device version.
Key Lock: Lock input/output and tare functions via DigiVision settings.
Adjustment for Calibration: Methods for calibration using physical variables or test and calibration certificate data.
Adjustment Procedures for Various Sensors: Detailed steps for adjusting strain-gage sensors, potentiometric displacement sensors, and transmitters or sensors with standard signal output.
Adjustment of the Counter Input: Configuration options for the 32-bit counter in various modes.
Customer Services: Burster offers on-site support, product training, and calibration services.
Technical Data: Refer to the data sheet for detailed technical specifications and electromagnetic compatibility information.
Accessories: Details of available accessories can be found in the data sheet.
Disposal: Dispose of batteries and instruments according to statutory regulations to protect the environment.
See more

Catalog excerpts

Operation Manual Instrumentation Amplifier Model 9250-1

OPERATION MANUAL Instrumentation amplifier Model 9250 Manufacturer: © 2023 burster burster praezisionsmesstechnik gmbh & co praezisionsmesstechnik gmbh & co kg kg All rights reserved Talstr. 1 - 5 Postfach 1432 DE -76593 Gernsbach DE -76587 Gernsbach Germany Germany Tel.: +49-7224-645-0 Fax: +49-7224-645-88 Email: [email protected] www.burster.com

 Open the catalog to page 1
Operation Manual Instrumentation Amplifier Model 9250-2

Warranty disclaimer All information in the present documentation was prepared and compiled with great care and reproduced in accordance with effective control measures. No warranty is provided for freedom from errors. We reserve the right to make technical changes. The present information as well as the corresponding technical data can change without notice. Reproduction of any part of this documentation or its processing or revision using electronic systems is prohibited without the manufacturer's prior written approval. Components, devices and measurement sensors made by burster präzisionsmesstechnik...

 Open the catalog to page 2
Operation Manual Instrumentation Amplifier Model 9250-3

EU-Konformitatserklarung (nach en iso/iec 17050-12010) EU-Declaration of conformity (in accordance with EN ISO/IEC 17050-1:2010) Name ties Ausstellers: issuer's name: Anschrift des Ausstellers: Issuer's address: Gegenstand der Erklarung: Object of the declaration: burster prazisionsmesstechnik gmbh & co kg Talstr. 1-5 76593 Gernsbach, Germany Messverstarker-Modul fur DMS, potentiometrische und DC/DC Sensoren Amplifier module for strain gauge, potentiometric and DC/DC sensors Modellnummer(n) (Typ): Model number/type: Diese Erklarung beinhaltet obengenannte Produkte mit alien Optionen This declaration...

 Open the catalog to page 3
Operation Manual Instrumentation Amplifier Model 9250-7

The following symbols on the 9250 instrumentation amplifier and in this operation manual warn of hazards. 1.1 Symbols used in the instruction manual 1.1.1 Signal words The following signal words are used in the operation manual according to the specified hazard classification. DANGER High degree of risk: indicates a hazardous situation which, if not avoided, will result in death or serious injury. A WARNING Moderate degree of risk: indicates a hazardous situation which, if not avoided, may result in death or serious injury. A CAUTION Low degree of risk: indicates a hazardous situation which,...

 Open the catalog to page 7
Operation Manual Instrumentation Amplifier Model 9250-9

2 Introduction IMPORTANT: Read the operation manual carefully before using the equipment, and keep for future reference. 2.1 Intended use DANGER The 9250 instrumentation amplifier must not be used in hazardous areas. • The 9250 instrumentation amplifier is not intended as a substitute for safety devices and protective equipment. Use safety devices and protective equipment. • The 9250 instrumentation amplifier is not suitable for medical applications or where people are at risk. • Do not connect voltages that are higher than those permitted in the specification. • Not suitable for safety-critical...

 Open the catalog to page 9
Operation Manual Instrumentation Amplifier Model 9250-10

2.2 Customer service 2.2.1 Customer service department For repair inquiries, please telephone our Service department on +49-7224-645-53, or email: [email protected] (Germany only). If you are outside Germany, you should contact your burster agent (see also www.burster.com). Please have the serial number to hand. The serial number is essential to establishing the definite technical status of the instrument and providing help quickly. You will find the serial number on the type plate of the instrumentation amplifier 9250. 2.2.2 Contact person If you have any questions relating to the instrumentation...

 Open the catalog to page 10
Operation Manual Instrumentation Amplifier Model 9250-11

2.4.2 Operating conditions The following requirements must be met when operating the 9250 instrumentation amplifier: • Always operate indoors • Maximum height above sea level 2000 m • Operate at temperatures between 0 °C and 60 °C • Humidity: 80% up to +31 °C, decreasing linearly above that temperature to 50% at Tmax, no condensation • Class of protection: 3 • Transient overvoltage category: CAT II • Supply voltage 11 ... 30 VDC • The mounting rail must be connected to the protective earth Note: Avoid condensation forming after transportation or storage. DANGER The 9250 instrumentation amplifier...

 Open the catalog to page 11
Operation Manual Instrumentation Amplifier Model 9250-12

2.5 Personnel Personnel must be familiar with the relevant regulations. They must follow these regulations. Only trained personnel who are familiar with the applicable safety regulations are permitted to operate the instrumentation amplifier 9250. We are happy to train your staff. To find out more, please look at our range of services at www.burster.com. The following components are supplied: • 9250 instrumentation amplifier • Operation manual • Warranty document • Test certificate • DigiVision configuration and analysis software, free-of-charge version (you can download the software from our...

 Open the catalog to page 12
Operation Manual Instrumentation Amplifier Model 9250-13

The warranty shall be deemed void immediately if you open or dismantle instrumentation amplifier 9250 during the warranty period. The 9250 instrumentation amplifier does not contain any parts that are intended to be serviced by the user. Only the manufacturer's own qualified personnel are permitted to open the 9250 instrumentation amplifier. It is not permitted to make any changes to the 9250 instrumentation amplifier without the written agreement of burster praezisionsmesstechnik gmbh & co kg. burster praezisionsmesstechnik gmbh & co kg does not accept liability for damages or injury if this...

 Open the catalog to page 13
Operation Manual Instrumentation Amplifier Model 9250-14

Device design Please refer to the data sheet for the 9250 instrumentation amplifier for full details of dimensions, weight, degree of protection etc. The 9250 instrumentation amplifier is intended for the acquisition and processing of sensor signals. The 9250 instrumentation amplifier is a fully configurable single-channel module that can be configured both using buttons and via the USB port. The 9250 instrumentation amplifier is ideally suited to measuring mechanical variables such as force, torque, pressure, acceleration, displacement and angle. Acquisition and processing of strain-gage, potentiometric,...

 Open the catalog to page 14
Operation Manual Instrumentation Amplifier Model 9250-15

Block diagram and potentials Block diagram of the 9250 instrumentation amplifier The PLC inputs and outputs, the TTL inputs and the voltage supply are galvanically isolated from the actual instrumentation electronics and therefore have their own ground terminals. A maximum voltage of 20 V is allowed between the respective terminals and PE. Model versions Please refer to the data sheet for details of the different model versions. You can obtain the latest data sheet and additional information on the 9250 instrumentation amplifier from https://bit.ly/3VbTDLo. Power supply The 9250 instrumentation...