1. Catalogs
  2. burster Measurement Solutions GmbH
  3. Operation Manual Instrumentation Amplifier Model 9250 2025

Operation Manual Instrumentation Amplifier Model 9250 2025

Operation Manual Instrumentation Amplifier Model 9250 2025
1 / 71 PagesView full catalog

Operation Manual Instrumentation Amplifier Model 9250 2025

Product catalog summary
Warranty Disclaimer: The document outlines a warranty covering material and production defects of the products, excluding liability for consequential damages from improper use and does not guarantee market success or suitability for specific purposes.
Contents Overview: The manual is organized into sections including safety instructions, device design, controls and connections, initial use, configuration, calibration, and customer services.
1. Safety Instructions: This section explains the symbols and conventions used to ensure user safety and proper handling of the device, using signal words like DANGER, WARNING, CAUTION, and NOTICE.
2. Introduction: Describes the intended use of the 9250 instrumentation amplifier, customer service contact information, and ambient conditions for storage and operation.
3. Device Design: Details the functions, signal processing, measurement quality, model versions, power supply, and compatible sensors of the amplifier.
4. Controls and Connections: Explains the controls, LEDs, and connections available on the amplifier, including sensor compatibility and output options.
5. Initial Use: Provides instructions for installing and removing the device.
6. Configuration: Offers guidance on manual and software-based configuration, including input selection, analog output configuration, and additional settings via DigiVision software.
7. Calibration: Describes the process for calibrating the amplifier with different types of sensors, including strain-gage and potentiometric sensors.
8. Customer Services: Information on available customer services for the 9250 instrumentation amplifier.
9. Technical Data: Includes specifications related to electromagnetic compatibility and interference immunity.
LED Indicators: The device features LEDs to indicate the status of PLC outputs, analog output modes, input configurations, and tare status, providing feedback on operational states and error conditions.
Control Buttons: The amplifier includes buttons for taring, input configuration, and output selection, allowing manual configuration of input and output settings.
Grounding and Shielding: Proper grounding via the mounting rail is essential, with recommendations for sensor lead length, system grounding, shielding, and signal line spacing.
Compatible Sensors/Inputs: Supports full-bridge strain-gage sensors, potentiometric sensors, voltage measurement/transmitters, and TTL incremental sensors, each with specific configuration options.
Outputs: Offers configurable analog voltage and current outputs, with options for 0 ... ±5 V, 0 ... ±10 V, 0 ... 20 mA, and 4 ... 20 mA, with only one output active and calibrated at a time.
PLC Inputs/Outputs: Separate PLC inputs and outputs can be assigned functions like tare/reset and limit buffer reset, with galvanic isolation from the instrumentation electronics.
Connection Methods: Provides detailed instructions for connecting various sensor types and covers burster TEDS connections and USB port specifications.
Installation and Configuration: The amplifier should be installed on a grounded mounting rail, with quick configuration possible via buttons and manual configuration for input and output options.
Performing Sensor Teach-In: Describes the process for activating calibration mode, setting calibration points, and saving the rescaling calibration.
Tare Function: Instructions for initiating and canceling the taring process.
Additional Settings via DigiVision: System requirements and software download instructions for configuring connected amplifiers.
Device List and Settings: Use DigiVision software to configure measurement mode, decimal places, units, sensor excitation voltage, and filter settings.
Configuring the Analog Output: Options for analog output configuration, with only one output active and calibrated at a time.
Configuring PLC I/O - Digital Inputs / Limits: Instructions for configuring outputs and inputs with dynamic or static limits.
Device Settings - Properties: View or set station name, calibration date, software version, serial number, and device version.
Key Lock: Lock input/output and tare buttons via DigiVision settings.
Adjustment for Calibration: Calibration instructions for strain-gage sensors, potentiometric displacement sensors, and transmitters or sensors with standard signal output.
Adjustment of the Counter Input: Configure the 32-bit counter in different modes and use the teach-in option if needed.
Customer Services: On-site support, product training, initial calibration, and recalibration services, with contact details for service inquiries.
Technical Data: Detailed specifications and compliance with EN 61326-1:2013 for interference immunity and emission.
Accessories and Disposal: Information on accessories and proper disposal methods as per statutory regulations.
See more

Catalog excerpts

Operation Manual Instrumentation Amplifier Model 9250 2025-1

OPERATION MANUALInstrumentation amplifier Model 9250 Manufacturer: praezisionsmesstechnik gmbh & co praezisionsmesstechnik gmbh & co kg kg All rights reserved Talstr. 1 - 5 Postfach 1432 DE -76593 Gernsbach DE -76587 Gernsbach Germany Germany Tel.: +49-7224-645-0 Fax: +49-7224-645-88 Email: [email protected] www.burster.com

 Open the catalog to page 1
Operation Manual Instrumentation Amplifier Model 9250 2025-2

Warranty disclaimer All information in the present documentation was prepared and compiled with great care and reproduced in accordance with effective control measures. No warranty is provided for freedom from errors. We reserve the right to make technical changes. The present information as well as the corresponding technical data can change without notice. Reproduction of any part of this documentation or its processing or revision using electronic systems is prohibited without the manufacturer's prior written approval. Components, devices and measurement sensors made by burster präzisionsmesstechnik...

 Open the catalog to page 2
Operation Manual Instrumentation Amplifier Model 9250 2025-3

EU-Konformitatserklarung (nach en iso/iec 17050-12010) Name ties Ausstellers: issuer's name: Issuer's address: burster prazisionsmesstechnik gmbh & co kg Talstr. 1-5 Messverstarker-Modul fur DMS, potentiometrische und DC/DC Sensoren Amplifier module for strain gauge, potentiometric and DC/DC sensors Modellnummer(n) (Typ): Model number/type: Diese Erklarung beinhaltet obengenannte Produkte mit alien Optionen This declaration covers all options of the above product(s) Das oben beschriebene Produkt ist konform mit den Anforderungen der folgenden Dokumente: The object of the declaration described...

 Open the catalog to page 3
Operation Manual Instrumentation Amplifier Model 9250 2025-7

The following symbols on the 9250 instrumentation amplifier and in this operation manual warn of hazards. Symbols used in the instruction manual 1.1.1 Signal words The following signal words are used in the operation manual according to the specified hazard classification. DANGER High degree of risk: indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING Moderate degree of risk: indicates a hazardous situation which, if not avoided, may result in death or serious injury. CAUTION Low degree of risk: indicates a hazardous situation which, if not avoided,...

 Open the catalog to page 7
Operation Manual Instrumentation Amplifier Model 9250 2025-9

2 Introduction IMPORTANT: Read the operation manual carefully before using the equipment, and keep for future reference. DANGER The 9250 instrumentation amplifier must not be used in hazardous areas. • The 9250 instrumentation amplifier is not intended as a substitute for safety devices and protective equipment. Use safety devices and protective equipment. • The 9250 instrumentation amplifier is not suitable for medical applications or where people are at risk. • Do not connect voltages that are higher than those permitted in the specification. • Not suitable for safety-critical applications....

 Open the catalog to page 9
Operation Manual Instrumentation Amplifier Model 9250 2025-10

2.2 Customer service2.2.1 Customer service department For repair inquiries, please telephone our Service department on +49-7224-645-53, or email: [email protected] (Germany only). If you are outside Germany, you should contact your burster agent (see also www.burster.com). Please have the serial number to hand. The serial number is essential to establishing the definite technical status of the instrument and providing help quickly. You will find the serial number on the type plate of the instrumentation amplifier 9250. If you have any questions relating to the instrumentation amplifier 9250,...

 Open the catalog to page 10
Operation Manual Instrumentation Amplifier Model 9250 2025-11

The following requirements must be met when operating the 9250 instrumentation amplifier: • Always operate indoors • Maximum height above sea level 2000 m • Operate at temperatures between 0 °C and 60 °C • Humidity: 80% up to +31 °C, decreasing linearly above that temperature to 50% at Tmax, no condensation • Transient overvoltage category: CAT II • The mounting rail must be connected to the protective earth Note: Avoid condensation forming after transportation or storage. DANGER The 9250 instrumentation amplifier is not intended as a substitute for safety devices and protective equipment. Use...

 Open the catalog to page 11
Operation Manual Instrumentation Amplifier Model 9250 2025-12

Personnel must be familiar with the relevant regulations. They must follow these regulations. Only trained personnel who are familiar with the applicable safety regulations are permitted to operate the instrumentation amplifier 9250. We are happy to train your staff. To find out more, please look at our range of services at www.burster.com. The following components are supplied: • Operation manual • Warranty document • Test certificate • DigiVision configuration and analysis software, free-of-charge version (you can download the software from our homepage https://www.burster.com/en/sensor-electronics/amplifier-and-transmitter-modules/p/detail/9250...

 Open the catalog to page 12
Operation Manual Instrumentation Amplifier Model 9250 2025-13

The warranty shall be deemed void immediately if you open or dismantle instrumentation amplifier 9250 during the warranty period. The 9250 instrumentation amplifier does not contain any parts that are intended to be serviced by the user. Only the manufacturer's own qualified personnel are permitted to open the 9250 instrumentation amplifier. It is not permitted to make any changes to the 9250 instrumentation amplifier without the written agreement of burster praezisionsmesstechnik gmbh & co kg. burster praezisionsmesstechnik gmbh & co kg does not accept liability for damages or injury if this...

 Open the catalog to page 13
Operation Manual Instrumentation Amplifier Model 9250 2025-14

Device design Please refer to the data sheet for the 9250 instrumentation amplifier for full details of dimensions, weight, degree of protection etc. The 9250 instrumentation amplifier is intended for the acquisition and processing of sensor signals. The 9250 instrumentation amplifier is a fully configurable single-channel module that can be configured both using buttons and via the USB port. The 9250 instrumentation amplifier is ideally suited to measuring mechanical variables such as force, torque, pressure, acceleration, displacement and angle. Acquisition and processing of strain-gage, potentiometric,...

 Open the catalog to page 14
Operation Manual Instrumentation Amplifier Model 9250 2025-15

Block diagram and potentials Block diagram of the 9250 instrumentation amplifier The PLC inputs and outputs, the TTL inputs and the voltage supply are galvanically isolated from the actual instrumentation electronics and therefore have their own ground terminals. A maximum voltage of 20 V is allowed between the respective terminals and PE. Model versions Please refer to the data sheet for details of the different model versions. You can obtain the latest data sheet and additional information on the 9250 instrumentation amplifier from https://bit.ly/3VbTDLo. Power supply The 9250 instrumentation...

 Open the catalog to page 15

All Burster Measurement Solutions GmbH catalogs and technical brochures

  1. Load-cell