Product catalog summary
Introduction
The document is an operation manual for the Fieldbus Controller Model 9251 by Burster Präzisionsmesstechnik GmbH & Co KG, detailing installation, operation, and maintenance instructions.
Warranty Disclaimer
No warranty is provided for error freedom, and technical changes can occur without notice. Reproduction of the document is prohibited without approval.
Safety Instructions
Safety is emphasized with signal words like DANGER, WARNING, and CAUTION. Symbols warn of electric shock hazards and stress the importance of following the manual.
Device Concept
Outlines the functional scope, block diagram, power supply requirements, and optional sensor technologies. Connects up to eight 9250 instrumentation amplifiers to Ethernet-based fieldbuses.
Controls and Connections
Details on front view, terminal assignments, fieldbus status indicators, and LED functions. Includes grounding, shielding, and compatible sensors information.
First-Time Use
Instructions for installation and removal ensure proper setup and operation.
PROFINET, EtherCAT, and EtherNET/IP
Explains planning and implementation of networks, port identification, LED functions, and data transmission protocols. Covers error codes and service data objects.
Technical Data
Operates at 11 to 30 V DC with a maximum power consumption of 3 W. Designed for indoor use at altitudes up to 2000 m and temperatures between 0 °C and 50 °C.
Error Indicators
Status LEDs indicate errors such as input overload or internal malfunctions, with a troubleshooting table provided.
Warranty and Service
24-month warranty with free repairs unless damage results from improper use. Contact details for service inquiries are provided.
Additional Information
Includes details on downloading the test certificate, storage and operating conditions, and restrictions on use. Only trained personnel should operate the device.
Status LED Indicators
Different colors and flashing patterns indicate various statuses, such as normal measuring mode or fieldbus module errors.
Grounding and Shielding
Proper grounding via the mounting rail is essential. Sensor leads should be short, and shielding continuous.
Compatible Sensors/Inputs
Supports voltage measurement with transmitters having a voltage output of up to ±10 V, requiring a separate power supply.
PLC Inputs and Outputs
Offers optional PLC inputs and outputs with functions like tare, reset, and dynamic/static limit thresholds.
Micro-USB Port
Used for configuration via DigiVision software, not for measurement operations.
Data Transmission Methods
'Short' for slow measurements or fast PLC communication, 'extended' for high measurement rates.
Safety and Installation
Use under specified conditions and install on a grounded mounting rail. Not for use in explosive areas or with higher voltages.
Data Protocols
Includes short and extended methods, cyclical and acyclical data communication processes.
EtherCAT Communication
Uses PDO and SDO data objects, with LED signals managing initialization and status indicators.
Port Identification
Integrates into the fieldbus network using two RJ45 ports.
EtherCAT Fieldbus-Specific LED Functions
LED indicators provide status information, adhering to EtherCAT specifications.
Service Offering
Burster offers on-site support, product training, and calibration services.
Technical Data and Accessories
Refer to the online data sheet for detailed specifications and available accessories.
Disposal Instructions
Outlines legal obligations for battery and instrument disposal, emphasizing environmental protection.
See more

Catalog excerpts

Operation Manual Fieldbus controller Model 9251-1

Valid from: OPERATION MANUAL Fieldbus controller Model 9251 burster prazisionsmesstechnik gmbh & co kg All rights reserved prazisionsmesstechnik gmbh & co kg Talstr. 1-5 Postfach 1432 Germany Germany

 Open the catalog to page 1
Operation Manual Fieldbus controller Model 9251-2

Warranty disclaimer All information in the present documentation was prepared and compiled with great care and reproduced in accordance with effective control measures. No warranty is provided for freedom from errors. We reserve the right to make technical changes. The present information as well as the corresponding technical data can change without notice. Reproduction of any part of this documentation or its processing or revision using electronic systems is prohibited without the manufacturer's prior written approval. Components, devices and measurement sensors made by burster präzisionsmesstechnik...

 Open the catalog to page 2
Operation Manual Fieldbus controller Model 9251-3

Fieldbus-Controller Model 9251 EU-Konformitatserklarung (nach en iso/iec 17050-1:2010) EU-Declaration of conformity (in accordance with EN ISO/IEC 17050-1:2010) Issuer's name: Issuer's address: burster prazisionsmesstechnik gmbh & co kg Talstr. 1-5 Model number /type: Diese Erklarung beinhaltet obengenannte Produkte mit alien Optionen This declaration covers all options of the above product(s) The object of the declaration described above Is in conformity with the requirements of the following documents: Xitel Title Richtlinie zur Beschrankung der Verwendung bestimmter gefahrlicher Stoffe in...

 Open the catalog to page 3
Operation Manual Fieldbus controller Model 9251-4

Fieldbus-Controller Model 9251 Declaration of Conformity (DOC) Reference Information File Number 12231.01 Part 1 oM Year Last Issued: 2022 Continues in effect so long as the named entity (i) remans an ODVA Licensee Vendor far the ODVA Length of technology; es; defined by the above specif cation(s); { ) continues bUH is user responsibilities as defined Validity; in rtsTerms of Usage Agreement with ODVA; and (iii)lheCF Identityfotthe Produces) remains identical to those enumerated in this Declaration of Conformity. ODVA Licensed Vendor to Whom this DOC has Been Issued Entity Name: burster jjnbh...

 Open the catalog to page 4
Operation Manual Fieldbus controller Model 9251-8

7.3.2 Data protocol for data transmission from the 9251 fieldbus controller to the control system 7.3.3 Data protocol for data transmission from the 9250 instrumentation amplifier to the control 7.3.4 Data protocol for data transmission from the control system to the 9251 fieldbus controller 7.3.5 Data protocol for data transmission from the control system to the 9250 instrumentation 8.6.2 Data protocol for cyclic data transmission from the 9251 fieldbus controller to the scanner 8.6.3 Data protocol for cyclic data transmission from the 9250 measuring amplifier to the 8.7.1 Data protocol for...

 Open the catalog to page 8
Operation Manual Fieldbus controller Model 9251-10

Fieldbus-Controller Model 9251 1 For your safety The following symbols on the model 9251 fieldbus controller and in this operation manual warn of hazards. 1.1 Symbols used in the operating manual The following signal words are used in the operating manual according to the specified hazard classification. DANGER High degree of risk: indicates a hazardous situation which, if not avoided, will result in death or serious injury. Moderate degree of risk: indicates a hazardous situation which, if not avoided, may result in death or serious injury. Low degree of risk: indicates a hazardous situation...

 Open the catalog to page 10
Operation Manual Fieldbus controller Model 9251-11

Fieldbus-Controller Model 9251 1.1.2 Pictograms

 Open the catalog to page 11
Operation Manual Fieldbus controller Model 9251-12

Fieldbus-Controller Model 92512 Introduction IMPORTANT: Read the operating manual carefully before using the equipment, and keep for future reference. DANGER • Only use the model 9251 fieldbus controller outside of potentially explosive • The model 9251 fieldbus controller is not intended as a substitute for safety devices and protective equipment. Use safety devices and protective equipment. ' • The model 9251 fieldbus controller is not intended for use in medical applications or where people are at risk. • Do not connect voltages that are higher than the specification allows. • For use in EMC-certified...

 Open the catalog to page 12
Operation Manual Fieldbus controller Model 9251-13

Fieldbus-Controller Model 92512.2.2 Contact person If you have any questions relating to the model 9251 fieldbus controller, please go directly to burster prazisionsmesstechnik gmbh & co kg, or if outside Germany, please contact your burster agent (see also www .burster.com). Head office burster prazisionsmesstechnik gmbh & co kg Talstr. 1-5 76593 Gernsbach GERMANY Email: [email protected] You have the option to download the test certificate for your model 9251 fieldbus controller online. To do this, use the following link https://tinvurl.com/v45kumv6. You can then download the test certificate...

 Open the catalog to page 13
Operation Manual Fieldbus controller Model 9251-14

Fieldbus-Controller Model 9251 2.4.3 Restrictions on use A DANGER The model 9251 fieldbus controller is not intended as a substitute for safety devices and protective equipment. Use safety devices and protective equipment. The model 9251 fieldbus controller does not pose a hazard if used within its specification and in accordance with the safety regulations. The manufacturer does not accept liability for any personal injury or property damage arising from misinterpretation of measurement results. Disconnect the model 9251 fieldbus controller from the power supply and use a dry cloth to clean...

 Open the catalog to page 14
Operation Manual Fieldbus controller Model 9251-15

DANGER Electrical shock hazard Never switch on the model 9251 fieldbus controller if it shows signs of damage incurred in transit. Only ever use the model 9251 fieldbus controller under the conditions specified in this operating manual. Inspect the model 9251 fieldbus controller for damage. If you suspect that the unit has been damaged during shipping, notify the delivery company within 72 hours. The packaging should be retained for examination by a representative of the manufacturer and/or the delivery company. The model 9251 fieldbus controller should be shipped only in its original packaging...

 Open the catalog to page 15
Operation Manual Fieldbus controller Model 9251-16

Device concept Please refer to the model 9251 fieldbus controller data sheet for full details of dimensions, weight, degree of protection etc. Functional scope The model 9251 fieldbus controller serves as a bridge between cascadable model 9250 universal instrumentation amplifiers and Ethernet-based fieldbuses such as PROFINET, EtherCAT and EtherNet/IP. Up to eight model 9250 instrumentation amplifiers, bus-compatible version, can be connected to the model 9251 fieldbus controller. The scaled measured values are read simultaneously in the real-time data of the fieldbus link. A DC standard signal...

 Open the catalog to page 16

All Burster Measurement Solutions GmbH catalogs and technical brochures

  1. Load-cell

    25  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.