Warranty Disclaimer: The document provides information without warranty for errors, and technical changes can occur without notice. The warranty covers material and production defects but excludes improper use or consequential damages.

1. For Your Safety: Signal words like DANGER, WARNING, and CAUTION indicate risk levels. Adhering to these notices is crucial for handling the model 8561 2-axis load cell safely.

2. Introduction: The load cell is designed for force measurement in production equipment. The manual includes customer service contact information, instructions for downloading the test certificate, ambient conditions for storage and operation, and cleaning instructions.

3. Concept and General Information: The load cell uses two spring elements forming bending beams to measure force with strain gages, minimizing cross-talk between perpendicular forces Fx and Fy.

4. Using the Instrument for the First Time: Grounding and equipotential bonding are necessary for safe operation.

5. Installation: Details on mechanical installation, fixing methods, and electrical system connections are provided.

6. Measurement Chain Calibration: Calibration procedures are outlined to ensure accurate measurements.

7. Technical Data: Information on electromagnetic compatibility, including interference immunity and emission, is included.

8. Accessories Available: A list of available accessories is provided.

9. Disposal: Instructions for proper disposal of the load cell are given.

Overview: The document provides detailed technical information and guidelines for the model 8561 2-axis load cell, which uses four bending beams and strain gages to measure force. It includes specifications, installation instructions, and operational guidelines.

Specifications: Constructed using aviation materials, the load cell converts force into a linear extension using a spring element and strain gages configured in a Wheatstone bridge to minimize measurement errors. The rated output is typically around 2 mV/V with a recommended excitation voltage of 5 V.

Installation and Usage: Proper installation requires a stable, hardened, and flat mounting surface. The load cell should be protected from external forces such as vibrations and torsional moments, which can affect measurement accuracy. Electrical connections must be insulated and protected from electromagnetic interference.

Calibration and Maintenance: Each load cell comes with a test and calibration certificate. Calibration of downstream electronics is necessary for accurate measurements. Regular checks for overload and proper grounding are recommended.

Technical Data and Compliance: The load cell complies with EN 61326-1:2013 and EN 61326-2-3:2006 standards for electromagnetic compatibility. Technical data and accessory details are available on the manufacturer's website.

Disposal: Users are advised to dispose of the load cell in accordance with statutory regulations to protect the environment.
See more

Catalog excerpts

OPERATING MANUAL 2-Axis Load Cell XY Model 8561-1

OPERATING MANUAL 2-Axis Load Cell XY Model 8561 burster präzisionsmesstechnik gmbh & co kg All rights reserved Valid from: Manufacturer: burster präzisionsmesstechnik gmbh & co kg Talstr. 1-5 Postfach 1432 76593 Gernsbach 76587 Gernsbach Germany Germany Tel.: +49 7224 645-0 Fax: +49 7224 645-88 Email: [email protected] www.burster.de 4038-BA8561EN-5999-021523

 Open the catalog to page 1
OPERATING MANUAL 2-Axis Load Cell XY Model 8561-2

Warranty disclaimer All information in the present documentation was prepared and compiled with great care and reproduced in accordance with effective control measures. No warranty is provided for freedom from errors. We reserve the right to make technical changes. The present information as well as the corresponding technical data can change without notice. Reproduction of any part of this documentation or its processing or revision using electronic systems is prohibited without the manufacturer’s prior written approval. Components, devices and measurement sensors made by burster präzisionsmesstechnik...

 Open the catalog to page 2
OPERATING MANUAL 2-Axis Load Cell XY Model 8561-6

The following symbols are used in this operation manual to warn of hazards. Symbols used in the operating manual 1.1.1 Signal words The following signal words are used in the operating manual according to the specified hazard classification. DANGER High degree of risk: indicates a hazardous situation which, if not avoided, will result in death or serious injury. WARNING Moderate degree of risk: indicates a hazardous situation which, if not avoided, may result in death or serious injury. CAUTION Low degree of risk: indicates a hazardous situation which, if not avoided, could result in minor or...

 Open the catalog to page 6
OPERATING MANUAL 2-Axis Load Cell XY Model 8561-7

IMPORTANT: Read the operating manual carefully before using the equipment, and keep for future reference. The load cells in the 8561 model series are primarily designed for the measurement of force in production equipment, using newtons (N) as the unit of measurement. The local gravitational acceleration (g ≈ 9.81 m/s²) must be taken into account when determining masses. 2.1.1 Customer service department For repair inquiries, please call our customer service department on +49 7224 645-53. Please have the serial number to hand. The serial number is essential to establishing the definite technical...

 Open the catalog to page 7
OPERATING MANUAL 2-Axis Load Cell XY Model 8561-8

2.3.1 Storage The model 8561 2-axis load cell must be stored under the following conditions: • dry • no condensation • temperature between 0 °C and 60 °C Note: Provided the storage conditions have been observed, no special steps need to be taken after storage and prior to commissioning. NOTICE Only connect the model 8561 2-axis load cell to instrumentation amplifiers that are fitted with a safety transformer to EN 61558. Transmitters connected to the outputs or other devices that are galvanically connected to the sensor’s signal lines must also be fitted with safety transformers to EN 61558....

 Open the catalog to page 8
OPERATING MANUAL 2-Axis Load Cell XY Model 8561-9

Personnel must be familiar with the relevant regulations. They must follow these regulations. Only trained personnel who are familiar with the applicable safety regulations are permitted to operate the model 8561 2-axis load cell. Contents of pack • 2-axis load cell, model 8561 • Connector socket 90° angle (9900-V647) • Test certificate CAUTION Never switch on the model 8561 2-axis load cell if it shows signs of damage incurred in transit. Only ever use the model 8561 2-axis load cell under the conditions specified in this operating manual. Inspect the model 8561 2-axis load cell for damage....

 Open the catalog to page 9
OPERATING MANUAL 2-Axis Load Cell XY Model 8561-10

The warranty shall be deemed void immediately if you open or dismantle the model 8561 2axis load cell during the warranty period. The model 8561 2-axis load cell does not contain any parts that are intended to be serviced by the user. Only the manufacturer’s own qualified personnel are permitted to open the model 8561 2-axis load cell. It is not permitted to make any changes to the model 8561 2-axis load cell without the written agreement of burster präzisionsmesstechnik gmbh & co kg. burster präzisionsmesstechnik gmbh & co kg does not accept liability for damages or injury if this condition...

 Open the catalog to page 10
OPERATING MANUAL 2-Axis Load Cell XY Model 8561-11

Concept and general information Please refer to the data sheet for the model 8561 2-axis load cell for full details of dimensions, weight, degree of protection etc. Mechanical design The model 8561 2-axis load cell consists of two spring elements in the form of bending beams, which are joined to the central part. Strain gages X/Y measuring elements with strain gages applied A radial force in the central part of the load cell deforms these measuring elements, causing a displacement of the measuring axis. The resulting elongation is not visible to the naked eye and is measured using strain gages....

 Open the catalog to page 11
OPERATING MANUAL 2-Axis Load Cell XY Model 8561-12

Foil strain gage Special techniques are used to mount strain gages manufactured in this way onto the surface of the spring element. Strain gage wiring In order to reduce undesirable influences on the measurement, in the model 8561 2-axis load cell four strain gages are connected as a Wheatstone bridge for each measurement direction. Figure 3 illustrates this wiring in a simplified form. Full-bridge strain gage on the model 8561 2-axis load cell for one measurement direction To reduce the effect of temperature, modulus-compensation strain gages are used. In addition to the four strain gages shown...

 Open the catalog to page 12
OPERATING MANUAL 2-Axis Load Cell XY Model 8561-13

External forces External forces here refers to any force that does not act radially to the sensor’s axis of symmetry – particularly transverse forces, bending moments and torsional forces. NOTICE Damage to the model 8561 2-axis load cell Avoid vibrations, even if the generated loads remain below the rated load and avoid external forces acting on the load cell. Design your measuring system in such a way as to prevent these external forces. IMPORTANT: External forces acting on the model 8561 2-axis load cell will significantly falsify the measurement result!

 Open the catalog to page 13
OPERATING MANUAL 2-Axis Load Cell XY Model 8561-14

Using the instrument for the first time CAUTION Never switch on the model 8561 2-axis load cell if it shows signs of damage incurred in transit. Only ever use the model 8561 2-axis load cell under the conditions specified in this operating manual. NOTICE Only connect the model 8561 2-axis load cell to instrumentation amplifiers that are fitted with a safety transformer to EN 61558. Transmitters connected to the outputs or other devices that are galvanically connected to the signal lines of the model 8561 2-axis load cell must also be fitted with safety transformers to EN 61558. Grounding and...