Data Sheet Model 9243

Data Sheet Model 9243

Data Sheet Model 9243

Product catalog summary
Overview: The document provides technical specifications and application details for the Burster Model 9243 amplifier module, designed for converting measurement signals from strain gauges, potentiometric sensors, or DC/DC sensors into standard signals. It is suitable for use in harsh environments with an IP65 version available.
Specifications:
  • Accuracy: < 0.05%
  • Outputs: ±5 V, ±10 V, and 0 (4) - 20 mA
  • Cut-off frequency: 1 kHz, optional 4 kHz
  • Configuration: Via DIP switches
  • Power Supply: 20 - 36 V DC or 14 - 26 V AC
  • Operating Temperature: 0 ... 60 °C
Technical Data:
  • Connectable Sensors: Strain gauges (350 ...1000 Ω), Potentiometers (1 kΩ ... 5 kΩ), DC/DC transmitters
  • Excitation Voltage: 2.5 V, 5 V, 10 V
  • Excitation Current: Max. 35 mA
  • Analog Output: Voltage output max. 11.5 V, Current output 0 ... 20 mA or 4 ... 20 mA
  • Gain: 0.5 ... 50,000 (via DIP switches + potentiometer)
Installation and Configuration: The amplifier module is designed for easy installation on DIN mounting rails. It features a 6-wire technique to avoid measurement errors due to line length or temperature fluctuations. Configuration is accessible via DIP switches located under a cover.
IP65 Version: The IP65 version is housed in cast-aluminium, suitable for screw mounting, and provides enhanced protection for use in rugged environments.
Accessories: Includes rail mounting transformer, plug-in socket, and DMS simulator for easy adjustment to SG sensors.
Applications: Suitable for use with strain gauge sensors (force, pressure, torque) and potentiometric sensors (displacement, angle).
See more

Catalog excerpts

Data Sheet Model 9243-1

Amplifier Module for strain gauge and potentiommetric sensors Isolation between signal and power supply Cut-off frequency 1 kHz, optional 4 kHz Easy installation on DIN mounting rail The amplifier module model 9243 is used wherever measurement signals from strain gauges, potentiometric sensors or DC/DC sensors have to be converted into standard signals. Simply by mounting on conventional DIN-mount rails, it is possible to position the amplifier module on location, in the proximity of the sensor. Especially for rough environments a IP65 version is available. The broad auxiliary power range and the choice between AC or DC permits operation on standard power supplies used in switch gear cabinets. A highly precise reference voltage source is built-in for calibration purposes. A calibrating shunt can also be connected via two separate terminals. This permits deliberate detuning of a strain gauge sensor for calibration or merely to check the measuring chain. A highly accurate precision amplifier performs the amplification of the sensor signal being applied. The necessary gain factor is adjusted coarsely with DIP switches while fine-tuning is carried out by using a potentiometer. Current and voltage outputs are available simultaneously. The sensor excitation is performed by the amplifier module itself so that no additional voltage source is required. It can also be set in steps of 2.5 V, 5 V, 10 V using DIP switches. The maximum feed current of 35 mA permits parallel connection of several strain gages, e.g. for the addition of measurement variables. Measurement errors brought about by varying line lengths or due to temperature fluctuations effecting the sensor cable are avoided by having probe lines measuring the actual feed voltage directly on site at the sensor itself (6 wire technology). Fluctuations are immediately corrected electronically. The cut-off frequency of the amplifier can be switched between 10 Hz and 1 kHz. The DIP switches for configuring the entire device are found easily accessible, under a cover. Technical changes reserved. All data sheets at www.burster.com burster praezisionsmesstechnik gmbh & co kg Germany www.burster.com Talstr. 1-5 . Gernsbach 76593 . Phone +49-7224-6450 [email protected] Rail mounting module

 Open the catalog to page 1
Data Sheet Model 9243-2

Technical Data Connection Schematic Connectable sensors Strain gauges ► for strain gauge sensors, e.g. force, pressure or torque sensors Bridge resistances: Connection technology: Sensitivity: Excitation voltage: Excitation current: Analog output Voltage output: max. 11.5 V at open terminals ±10 V Current output: 0 ... 20 mA or 4 ... 20 mA Load: 200 ... 500 Ω Input impedance: 1 GΩ Output impedance: with 10 V output: 470 Ω with monitor output: 10 kΩ General amplifier data Gain: 0.5 ... 50 000 (via DIP switches + potentiometer) Shift zero point: up to 100 % possible Accuracy: < 0.05% Temperature...

 Open the catalog to page 2

All Burster Measurement Solutions GmbH catalogs and technical brochures

  1. Load-cell

    25  Pages