Data Sheet Model 9210

Data Sheet Model 9210

Data Sheet Model 9210

Product catalog summary
Product Overview: The Model 9210 is a digital instrumentation amplifier designed for strain gage sensors, featuring an IO-Link interface. It facilitates the digitalization of measurement technology directly from the sensor, offering a compact design suitable for various field applications.
Key Features:
  • Universal strain gage amplifier with IO-Link interface.
  • Non-linearity of less than 0.005% of full scale.
  • Designed for harsh environments with IP65 protection and high vibration resistance.
  • Compact and installation-friendly design.
Applications: Suitable for mechanical and plant engineering, assembly and joining equipment, and measuring cell expansion during battery production.
Technical Specifications:
  • Compatible with full-bridge strain gage sensors.
  • Excitation voltage of 2.5 V, short-circuit proof.
  • Measuring range of ±9.5 mV, configurable rated outputs up to ±3.8 mV/V.
  • Supply voltage of 18-30 V DC via IO-Link interface with current consumption under 40 mA.
  • 24-bit A/D conversion with a maximum measurement rate of 1000 values per second.
  • Thermal zero drift of less than 0.01% per 10 K and repeatability of less than 0.01%.
  • Signal-to-noise ratio at 1 mV/V greater than 75 dB.
IO-Link Interface:
  • Version 1.1, Class A port type, with a baud rate of 230.4 kbaud (COM3).
  • Process data length of 32 bits with a cycle time of ≥ 1 ms.
  • Supports SIO mode and fully configurable I/O functionality.
Housing and Environmental Conditions:
  • Aluminum housing with dimensions of 62 x 22 x 24 mm.
  • Operating and storage temperature range from -40 to +85 °C.
  • Conforms to IP65 protection standards and various IEC vibration and shock standards.
Calibration and Accessories:
  • Offers standard and special factory calibration certificates, with options for accredited calibration certificates.
  • Accessories include various M8 and M12 connectors and cables.
Ordering Information: Example order includes precision miniature tension & compression load cell and strain gage amplifier with IO-Link interface.
See more

Catalog excerpts

Data Sheet Model 9210-1

burster Digital instrumentation amplifier for strain gage sensors with IO-Link interface MODEL 9210Highlights ■ Universal strain gage amplifier with lO-Link interface ■ Specified for use in harsh environments ■ IP65 degree of protection and high vibration resistance ■ Installation-friendly, ultra compact design ■ Mechanical and plant engineering ■ Assembly and joining equipment ■ Measuring cell expansion during battery production The new strain gage amplifier with IO-Link interface enables digitalization of the measurement technology right from the sensor. Its compact design and high degree of protection allow the instrumentation amplifier to be used practically anywhere in the field. Strain gage sensors typically have an output voltage of a few millivolts. In industrial environments, e.g. in the vicinity of electric motors or frequency converters, interference can affect the measurement result when transmitting analog signals. This is reliably avoided using the new strain gage amplifier with IO-Link interface. The analog link between the sensor and instrumentation amplifier is kept as short as possible, the standardized IO-Link communication is fully digital and interference-free. The amplifier is powered directly via the IO-Link interface - a standardized 5-wire cable with M12 socket. Strain gage sensors can be connected via a 4-pin M8 connector. The high-grade amplifier electronics enable precise measurements with a non-linearity of < 0.005 % F.S. 24-bit A/D conversion ensures that the digital signals have sufficient resolution. The new strain gage amplifier with IO-Link interface enables immense flexibility. With a suitable choice of IO-Link master, the instrumentation amplifier can be integrated into almost any fieldbus network. Depending on how many ports the master module provides, multi-channel measurement tasks can be implemented simply and cost-effectively. burster Sensors and Process Instruments - Technical changes reserved. All data sheets at www.burster.com

 Open the catalog to page 1
Data Sheet Model 9210-2

burster Sensors and Process Instruments - Technical changes reserved. All data sheets at www.burster.com

 Open the catalog to page 2
Data Sheet Model 9210-3

Electrical connection Electrical connection sensor end Electrical connection control end Block diagram burster Sensors and Process Instruments - Technical changes reserved. All data sheets at www.burster.com

 Open the catalog to page 3
Data Sheet Model 9210-4

burster Sensors and Process Instruments - Technical changes reserved. All data sheets at www.burster.com

 Open the catalog to page 4
Data Sheet Model 9210-5

Example orderOrder number 8431-6002-N0D0S000 Precision miniature tension & compression load cell with fitted M8 connector 92ABG Calibration of measuring chain 9210-V000 Strain gage amplifier with IO-Link interface burster Sensors and Process Instruments - Technical changes reserved. All data sheets at www.burster.com

 Open the catalog to page 5

All Burster Measurement Solutions GmbH catalogs and technical brochures

  1. Load-cell

    25  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.