Data Sheet Model 4463

Data Sheet Model 4463

Data Sheet Model 4463

Product catalog summary
Product Overview
The DIGISTANT® Model 4463 is a high-precision multifunction calibrator designed for voltage, current, thermocouples, RTDs, resistance, and frequency. It offers superior accuracy with an error limit of 0.002% across the voltage range and includes a DAkkS certificate.

Specifications
  • DC Voltage: Range from ±100 nV to ±100 V with accuracy from 0.002%.
  • DC Current: Range from ±100 nA to ±50 mA with accuracy of 0.005% ±1 µA.
  • Thermocouples: Supports 12 types with accuracy from 0.1 K.
  • RTD Simulation: Supports Pt100 to Pt1000 and Ni100 to Ni1000.
  • Resistance Simulation: True ohmic resistance from 10 Ω to 300 kΩ.
  • Frequency Simulation: Range from 10 mHz to 15 kHz.

Features
The device features a high-resolution color display, intuitive menu navigation, and can be controlled via Ethernet, USB, or RS-232. It supports LabView drivers and SCPI commands for integration. It includes 32 ramp functions per range with 100 value/time sequences.

Applications
Suitable for testing DC voltage and current measuring devices, thermocouple and temperature measuring instruments, and calibration of controllers, sensors, and PLC analog inputs.

Options and Accessories
Includes options for RTD simulation, user-specific RTD profiles, and various cables and mounting kits. An external reference junction model 4485-V001 is available for precision thermocouple simulation.

Calibration and Certification
Initial DAkkS calibration is included, with recommendations for periodic recalibration. Calibration certificates are available for different configurations and external reference junctions.

Technical Data
Detailed technical specifications are provided for voltage, current, thermocouple simulation, RTD simulation, resistance simulation, and frequency output. The device operates within a temperature range of +5 °C to +45 °C and has a storage temperature range of -10 °C to +55 °C.

General Information
The device is powered by 115 V/230 V with a maximum power consumption of 60 W. It weighs 5.7 kg and includes a warranty of 24 months.
See more

Catalog excerpts

Data Sheet Model 4463-1

Delivery: ex stock | Warranty: 24 months High-Precision Multifunction Calibrator for Voltage, Current, Thermocouples, RTDs, Resistance and Frequency DIGISTANT® MODEL 4463 Highlights ■ DC voltage ±100 nV ... ±100 V (accuracy from 0.002 %) ■ 12 thermocouple types (accuracy from 0.1 K) ■ 32 automatic ramp functions per measured variable, each with 100 values ■ LabView driver for software integration ■ True ohmic resistance simulation 10 Q ... 300 kQ ■ Testing DC voltage and current measuring devices ■ Testing thermocouple and temperature measuring instruments ■ Controlling process sequences using the ramp function ■ Calibration of RTD and thermocouple displays ■ Calibration of controllers, sensors and PLC analog inputs ■ Calibration of multimeters and other devices Product description The DIGISTANT® model 4463 is a high-precision calibration source with impressive versatility and accuracy. Every device is supplied with a DAkkS certificate. Compared to other calibrators, it offers a better error limit of 0.002 % across the entire voltage range. To achieve consistently high quality levels and conform to standards and regulations, measuring instruments of all kinds require regular calibration. The DIGISTANT® model 4463 provides many of the functions needed for this purpose. Inaccuracies caused by the measuring leads can be compensated via sense lines using 4-wire technology. All relevant information about the parameter settings and the accuracy being achieved is clearly laid out on the high-resolution color display. The dynamic menu system is navigated intuitively. Range selection is automatic or manual. Values can be entered precisely using the numeric or cursor keypad. The device can be controlled via its Ethernet, USB or RS-232 port. LabView drivers for software integration are available free of charge. SCPI commands are listed in the user manual. 32 ramp functions per range with 100 value/time sequences can be automatically saved and started. For thermocouples, scales including ITS-90 and IPTS-68, reference junction type constant or external, can be selected. An optionally available external Pt100 reference junction with calibration data taken into account in the device minimizes thermal EMFs and results in even smaller uncertainties in the measurement chain. burster Calibration Instruments - Technical changes reserved. All data sheet at www.bu

 Open the catalog to page 1
Data Sheet Model 4463-2

Technical Data DC voltage Resolution Accuracy (1 year) Maximum load Resolution Accuracy (1 year) Maximum load Thermocouple simulation Frequency output (only with -V0001) Range Resolution Accuracy (1 year) Range Resolution Accuracy (1 year) Output Open collector, max. 30 V/50 mA or internal pull-up 100 Q to +5 V (±10 %) Frequency measurement (only with -V0001) Frequency resolution Accuracy (1 year) Ambient conditions Reference temperature Operating temperature Storage temperature 23 °C ±10 °C (voltage, current, thermocouple simulation and frequency) 23 °C ±2°C (RTD and resistance) 4795-004463EN-5699-061532...

 Open the catalog to page 2
Data Sheet Model 4463-3

variable heating ph ase* Clock time Main value *The symbol appears on the display when the device temperature is outside the rated temperature range. The specified accuracy cannot be guaranteed during the warm-up phase. Auxiliary and main parameters for all functions can be saved via the presets. Otherwise they would be lost when the device restarts. Startup (position 00) loads automatically each time the device starts. Up to 100 presets can be saved and used later as required, avoiding the need to re-enter all the parameters. This function is particularly useful for recurring test scenarios,...

 Open the catalog to page 3
Data Sheet Model 4463-4

Calibration certificate with accreditation symbol The purchase of this product includes an initial calibration of the relevant functions. Please note, however, that the frequency range is NOT calibrated. We recommend a recalibration according to the recalibration deadlines specified. Further information at: www.burster.com Measuring points Current Thermocouple RTD (measurement) Frequency (measurement) Frequency (transmission) ■ For precision simulation of thermocouples ■ Integrated Pt100 for temperature measurement ■ Thermically stable and decoupled set-up ■ Connection: Miniature thermo plug...

 Open the catalog to page 4
Data Sheet Model 4463-5

Mounting kit model 4463-Z001 Fitted state Complete kit 4463-Z001 incl. 19"/5HE front panel, handles and 4 mounting profiles burster Calibration Instruments - Technical changes reserved. All data sheet at www.burster.com

 Open the catalog to page 5

All Burster Measurement Solutions GmbH catalogs and technical brochures

  1. Load-cell

    25  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.