1. Catalogs
  2. burster Measurement Solutions GmbH
  3. Data Sheet High Pressure Transducer Model 8221

Data Sheet High Pressure Transducer Model 8221

Data Sheet High Pressure Transducer Model 8221

Data Sheet High Pressure Transducer Model 8221

Product catalog summary
Overview: The document provides detailed technical specifications and application information for the High Pressure Transducer Model 8221 by Burster Praezisionsmesstechnik GmbH & Co KG. This sensor is designed for high-pressure applications, ensuring reliability and safety in environments such as water-jet cutting and hydraulic systems.
Applications: The transducer is suitable for use in laboratories, production, aeronautical engineering, cutting equipment, hydraulics, and test benches. It supports measuring ranges from 0 to 1000 bar up to 5000 bar with an accuracy of ≤ 0.2% F.S.
Key Specifications:
  • Accuracy: ≤ 0.2% F.S.
  • Medium temperature range: -30°C to 120°C
  • Protection class: IP66
  • Dynamic performance: Recommended at 70% of capacity
  • Material: Stainless steel 15-5PH for measuring element, AISI 304 for housing
  • Electrical connection: 6 pin bayonet or 4 pin M12 x 1 connector
Technical Data:
  • Bridge resistance: 350 Ω
  • Excitation voltage: 10-15 VDC or AC
  • Nominal sensitivity: 1.0 mV/V ± 1%
  • Insulation resistance: > 1000 MΩ at 50 V DC
  • Operating temperature: -30°C to 105°C
  • Overload capacity: 100% over capacity or max 6 kbar
  • Burst pressure: 300% over capacity or max 7.5 kbar
Features: The sensor includes a monolithic membrane for precision and safety, relief holes for pressure measurement under adverse conditions, and an integrated shunt resistor for easy calibration. It also offers digital calibration with an integrated amplifier option.
Accessories: Various connecting cables and mating connectors are available, including options for sensors without amplifiers and those with open cable ends.
Calibration: The factory calibration certificate includes a standard 11-point calibration, with special calibrations available upon request.
Ordering Information: The document provides order codes for different configurations of the transducer, including options for internal amplifiers and different thread types.
See more

Catalog excerpts

Data Sheet High Pressure Transducer Model 8221-1

High Pressure TransducerModel 8221 Resistant to shock and vibration Application The reliability and safety of a sensor is extremely important, particularly in high-pressure applications such as water-jet cutting equipment and hydraulic circuits. The dynamic loading encountered in these applications requires the use of sensors that are specially adapted for high pressure ranges. It is exactly these tough requirements that are satisfied by the model number 8221 sensor. With dynamic pressures, for example, an unlimited number of measurements can be taken if the pressure lies within the range from 0 ... 70% full scale. The strong construction allows liquid or gaseous media to be measured in the laboratory, production department or in mobile hydraulic applications. ■ Measuring ranges from 0 ... 1000 bar to 0 ... 5000 bar ■ Accuracy < 0.2 % F.S. ■ Medium temperature range from - 30 °C ... 120 °C ■ Ideal for dynamic measurements ■ Protection class IP66 ■ Digital calibration with the option of integrated instrumentation amplifier Description The monolithic sensor membrane guarantees a high level of precision, reliability and safety, since the medium does not come into any contact with welded seams. Great emphasis has been placed on safety in the mechanical design. It is fitted with relief holes, which permit the measurement of static and dynamic pressures, even under unfavorable environmental conditions. In order to facilitate the exchange of the sensors without having to recalibrate the following electronics, the sensitivity of the high-pressure sensor is standardized at 1.0 mV/V. The sensor is fitted with an integrated shunt resistor to enable easy calibration or checking of the subsequent electronics. Technical changes reserved. All data sheets at www.burster.com In combination with the option of an integrated amplifier (0 ... 10 V, 0 ... 5 V and 4 ... 20 mA) the new, innovative function for digital calibration can be used: All that is necessary is to touch the marked surface of the sensor with the enclosed magnetic pen. burster praezisionsmesstechnik gmbh & co kg Germany www.burster.com Talstr. 1-5 ■ Gernsbach 76593 ■ Phone +49-7224-6450 [email protected]

 Open the catalog to page 1
Data Sheet High Pressure Transducer Model 8221-2

Technical Data Order Code E l e c t r i a l v a l u e s Bridge resistance: metal-coated strain gauge 350 Q, nominal Calibration resistor: integrated in sensor; Activated by bridging pin E and F. The resulting bridge output voltage is shown in the test certificate 80 % F.S. ± 1 % E n v i r o n m e n t a l c o n d i t i o n s Range of operating temperature: Nominal temperature range: Medium temperature range: Influence of temperature on zero: Influence of temperature on sensitivity: M e c h a n i c a l v a l u e s Accuracy: sum of linearity error, hysteresis error and precision error: Measuring...

 Open the catalog to page 2

All Burster Measurement Solutions GmbH catalogs and technical brochures

  1. Load-cell

    25  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.