Catalog excerpts
DATA SHEET Vibrating filling level switch • For universal applications such as filling level detection or dry run protection system • Installation without adjustment • Smallest installation dimensions Product variants described in the data sheet may differ from the product presentation and description. Can be combined with Type 2030 Pneumatically operated 2/2 way diaphragm valve CLASSIC with plastic body Type 8644 Remote Process Actuation Control System AirLINE Type 2301 Pneumatically operated 2 way Globe Control Valve ELEMENT Type description The Type 8110 is a filling level switch for liquids, using a tuning fork as the sensor element. It is designed for industrial use in all areas of process technology and can be used in liquids. Typical applications are overfill or dry run protection. The small tuning fork (40 mm in length) can be used in vessels, tanks and tubes. Due to the simple and rugged measuring system, the 8110 is virtually unaffected by the chemical and physical features of the liquid. It also works under unfavourable measurement conditions such as turbulence, air bubbles, foam generation (not suitable for measuring the foam thickness itself), adhesions, strong external vibrations or varying filling materials. Type 8619 multiCELL - Multi-channel and multi-function transmitter/controller 1000079485 | Standard | EU | en | 202002 | 12 © Christian Bürkert GmbH & Co. KG, Subject to alteration
Open the catalog to page 1Table of contents 1. General Technical Data Visit product websit
Open the catalog to page 21. General Technical Data Note: The vibrating level switch is available with transistor (PNP) output or with contactless electronic output. The technical data depends on the vibrating level switch version. The common technical data are described in this chapter and detailed information on the specifics can be found in chapter “2. Product versions” on page 4. Product properties Material Please make sure the device materials are compatible with the fluid you are using. Detailed information can be found in chapter “3.1. Chemical Resistance Chart – Bürkert resistApp” on page 5. Detailed...
Open the catalog to page 3Environment and installation Ambient temperature Temperature derating Relative air humidity • Storage and transport: - 40…+ 80 °C (- 40…+ 176 °F) Detailed information can be found in chapter “6.1. Installation notes” on page 8. 20…85 %, without condensation 2. Product versions 2.1. Vibrating level switch with PNP transistor output Product details Operating voltage Load current Voltage loss Switching voltage Blocking current Electrical connection Degree of protection according to IEC/ EN 60529 Protection class according to IEC 61010‑1 9.6…35 V DC Max. 250 mA (output, permanently...
Open the catalog to page 43. Materials 3.1. Chemical Resistance Chart – Bürkert resistApp Bürkert resistApp – Chemical Resistance Chart You want to ensure the reliability and durability of the materials in your individual a pplication case? Verify your combination of media and materials on our website or in our resistApp. Start Chemical Resistance Check Element Screw Cable plug EN175301‑ 803 Process connection Tuning fork Multipin M12 × 1 cable plug with cap • Plug seal in silicone Plastic PEI (Polyetherimide) and stainless steel 316L (1.4404) Stainless steel 316L (1.4435) Stainless steel 316L (1.4435) • Contact...
Open the catalog to page 54. Dimensions 4.1. G ½" or NPT ½" connection Note: Dimensions in mm With M12×1 male fixed connector With cable plug acc. to EN 175301-803 ~36 1.) Keep in mind that the total length is increased by the cable connection 4.2. G ¾" or NPT ¾" connection Note: Dimensions in mm With M12×1 male fixed connector With cable plug acc. to EN 175301-803 ~36 1.) Keep in mind that the total length is increased by the cable connection Visit produ
Open the catalog to page 64.3. G 1"or NPT 1" connection Note: Dimensions in mm With M12×1 male fixed connector With cable plug acc. to EN 175301-803 ~36 1.) Keep in mind that the total length is increased by the cable connection 4.4. Clamp 2" connection Note: Dimensions in mm With M12×1 male fixed connector 13.5 1.) Keep in mind that the total length is increased by the cable connection Visit product webs
Open the catalog to page 75. Performance specifications 5.1. Temperature derating diagram 6. Product installation 6.1. Installation notes Note: • Inflowing material: If the Type 8110 vibrating level switch is mounted in the filling stream, unwanted switching signals can be generated. Mount the switch at a location in the vessel where no disturbing influence from e.g. filling openings, agitators, etc, can occur. • Flow: If there is movement within the product, the tuning fork of the switch should be mounted in such a way that the surfaces of the fork are parallel to the product movement The 8110 vibrating level...
Open the catalog to page 8Vertical installation Horizontal installation Switching point Switching point with lower density Switching point approx. 11 mm Switching point approx. 34 mm Recommended mounting position, particularly for adhesive products Switching point with higher density Marking with screwed version on top Switching point 7. Product operation 7.1. Measuring principle The tuning fork is piezoelectrically energised and vibrates at a mechanical resonance frequency of approx. 1100 Hz. When the tuning fork is submerged in the product, the frequency changes. This change is detected by the integrated...
Open the catalog to page 98.2. Bürkert product filter Bürkert product filter – Get quickly to the right product You want to select products comfortably based on your technical requirements? Use the Bürkert product filter and find suitable articles for your application quickly and easily. Try out our product filter 8.3. Ordering chart Output Operating voltage Contactless electronic switching output (not with PLC) Electrical connection Cable plug EN 175301‑803 Multipin M12 × 1 Cable plug EN 175301‑803 Multipin M12 × 1 Cable plug EN 175301‑803 Multipin M12 × 1 Cable plug EN 175301‑803 Multipin M12 × 1 Cable plug EN...
Open the catalog to page 10All BÜRKERT FLUID CONTROL SYSTEMS catalogs and technical brochures
-
Type 0121
16 Pages
-
Type 6240
26 Pages
-
Type 8020
10 Pages
-
Type 8026
12 Pages
-
Type 8605
13 Pages
-
Type 8692
18 Pages
-
Type 5470
15 Pages
-
8041
10 Pages
-
Type 0498
6 Pages
-
Type 8081
9 Pages
-
Type 2300
32 Pages
-
Type 8012
21 Pages
-
Type 8010
14 Pages
-
8222
8 Pages
-
Type 8137
12 Pages
-
Typ 8804
12 Pages
-
Product Overview MicroFluidics
18 Pages
-
Proportional Valves
17 Pages
-
Process and Control Valves
39 Pages
-
Measurement devices
68 Pages
-
S.EV series solenoid valves
16 Pages
-
Pivoted armature valve 330
13 Pages
-
Solenoid valves 6240
9 Pages
-
Solenoid Valves
31 Pages
-
6240
11 Pages
-
Type 0301
4 Pages
-
Type 0201
4 Pages
-
Type 0300
6 Pages
-
Type 0200
6 Pages
-
Type 0131
4 Pages
-
Type 0142
4 Pages
-
Type 0117
3 Pages
-
Type 0293
3 Pages
-
Process & Control Valves
33 Pages
-
Diaphragm Competence
14 Pages
-
Standard Product Program
13 Pages
-
AirLINE SP
2 Pages
-
multiCELL Type 8619
5 Pages
-
Flowmeter Type 8045
4 Pages
-
eControl Type 8611
2 Pages
-
Dosing Systems
4 Pages
-
Micro Valve: Whisper Valve
5 Pages
-
Mass Flow Controllers for Gases
16 Pages
-
Industrie-Flyer Food_En
4 Pages
-
CUT Product Line
9 Pages
-
CATALOGUE BURKERT SELECT
88 Pages
-
Cooling Towers
2 Pages
-
MicroFluidics
2 Pages
-
Fuel Cell Tech
2 Pages
-
Robot Welding
2 Pages
-
Plastic Extruding
2 Pages
-
Plastic Extrusion Lines
2 Pages
-
Flyer Cooking
2 Pages
-
Injection Molding
2 Pages
-
Heat Exchanger
2 Pages
-
Clean Steam
2 Pages
-
Flyer Control Cabinet Solutions
16 Pages
-
Flyer Hygienic Processing Pharma
32 Pages
-
Food and Beverage
32 Pages
-
Industrial Inkjet Printing
2 Pages
-
Segment Brochure Gas Handling
17 Pages
-
Systemhaus Brochure
8 Pages
-
Company profile
15 Pages
-
Product Catalogue:Bürkert Select
88 Pages
-
Cooling Systems Brochure
16 Pages
-
Water Treatment Brochure
16 Pages
-
MicroFluidics Brochure
16 Pages
-
steam products
16 Pages
-
Product Overview Pneumatics
24 Pages
-
Product overview Sensors
52 Pages