Catalog excerpts
• Easy to maintain design • Compact installation dimensions • Rugged cooling matrix • System-compatible cooling matrix / flow rate ratio • Extensive accessories • High suction pump
Open the catalog to page 1Introduction and description Why coolers? In many cases, installing an off-line cooler is not only an emergency solution, but also the best solution with respect to mechanics and economics. Oftentimes off-line filtration can also be incorporated quite effectively. Since a bypass also always requires installation of a separate circulation pump, it’s reasonable to combine it with the motor already installed for the fan. The BNK series is a tiered line of oil/air coolers with circulation pump directly flange-mounted. The cooler size and pump flow rate are coordinated for performance grades...
Open the catalog to page 2Model key BNK 4.4-30-0.75kW- IBx - T50 Motor power Pump output per litre Number of motor contacts Frame size To also have a bypass and/or thermal contact, the specification will be added to the type designation: BNK 4.4-30-0.75kW- IBx - T50 Bypass version Temperature switch external bypass internal bypass internal temperature-dependent bypass 2 bar / 45 °C external temperature-dependent bypass 2 bar / 45 °C bypass value 2 bar, 5 bar, 8 bar Temperature in °C, specification see separate data sheet Technical data Technical data Materials / surface protection Cooling battery: Ventilation box,...
Open the catalog to page 3Basic data (at 50 Hz frequency) Item no. Cooler model spec. cool- Cooling ing power power at kW/K ETD = 40 K (kW) max. circu- Motor power lation rate Number of poles (l/min) Rated current at 400 V We reserve the right to amend specification.
Open the catalog to page 4Calculation example and nomenclature tÖE [°C] specific cooling performance (see performance curves): Pspez = P / ETD Specific heat capacity of the oil (approx. 2.0 kJ / kgK) Calculation example Assumptions: Tank capacity Determining the cooler size: Pspez = P / ETD = 7.2 kW / 30 K = 0.24 kW/K Calculating P from the tank warming kg . kJ . 200 l .0.9 (318 K - 288 K) 2 V . ς . cOil. (T2 - T1 ) l kg .K P= = = 7.2 kW t 1500 s Select a cooler from the basic data with Pspez 0.24 kW/K. There is one option: BNK 3.4 with 30 L pump
Open the catalog to page 5*Connection for G ½ temperature switch Model
Open the catalog to page 6Functional diagram recommended position of additional oil filter The oil inlet is on the left of the cooling battery. The The oil inlet is on the bottom left of the cooling bat- oil outlet is always on the opposite side. tery. The second connection at the top must be closed. The oil outlet is always on the opposite External bypass AB/ATB (BNK 2-8) The oil inlet and outlet is always on the same side The oil inlet is always at the bottom left of the cool- of the cooling battery. The connection on the op- ing battery. The second connection must be posite side must be closed. closed. The oil...
Open the catalog to page 7All Bühler Technologies catalogs and technical brochures
-
Gas cooler series TC-MINI
6 Pages
-
sample gas probe GAS 222.10
2 Pages
-
Oil/air cooler BLK ATEX-3GD
7 Pages
-
Off-line cooler BNK ATEX-2GD
6 Pages
-
Off-line cooler BNK ATEX-3GD
6 Pages
-
Circular pumps BFP
7 Pages
-
Circular pumps BFP ATEX-2GD
8 Pages
-
Buhler catalogue for Fluid Control
434 Pages
-
Bühler Gas Analysis catalogue
394 Pages
-
Safety Flow Meter S-SM
2 Pages
-
Controllers
2 Pages
-
Flow Meter SM-6
2 Pages
-
Panel Filter AGF - FA - 5
2 Pages
-
Panel Filter AGF - FE 4
2 Pages
-
Panel Filter AGF - FE
2 Pages
-
Sample Gas Filter AGF - T 30
2 Pages
-
display and control unit
2 Pages
-
VSA 24-DM / DH / DP
2 Pages
-
BWT platecooler series
8 Pages
-
Capacity sensor VSA 24-SM
2 Pages
-
Nivotemp 61-0 WW series
2 Pages
-
Water alarm WW 6 series
2 Pages
-
GAS 222.20
2 Pages
-
BNF off line filter
6 Pages
-
NV 71
6 Pages
-
NT 67 XP
3 Pages
-
NT 61
9 Pages
-
NT M
4 Pages
-
SM series
2 Pages
-
P 1.1
3 Pages
-
AHF
2 Pages
-
BF 2-S
2 Pages
-
AGF
2 Pages