Level and temperature switch with display NT 61D § Highly visible LED display indicates the switching outputs, able to rotate 270° § Up to 4 programmable temperature switching outputs § Continuous temperature signal (adjustable current or voltage) plus one programmable output § Switching output adjustable as window or hysteresis § Two switching outputs adjustable as frequency output (1 to 100 Hz) § Menu structure based on the VDMA guidelines § Min/Max memory, logbook function Level and temperature switch NT 61 § Flange according to DIN 24557 / Part 2 § Various connector options § Up to 4 level outputs or 2 switching level outputs plus RTD or analog output for temperature § Reliable dynamic float system § Stainless steel option for temperatures up to 150 °C § Probe length up to 1.5 m (longer on request) § Voltage up to 230 V applicable Bühler Technologies GmbH D - 40880 Ratingen, Harkortstr. 29 Tel.: + 49 (0) 2102 / 49 89-0 Fax: + 49 (0) 2102 / 49 89-20 Internet: www.buehler-technologies.com e-mail: [email protected]
Open the catalog to page 1VA SS 1.4571 (SK 221) SS 1.4571 PA stainless steel W11 change over 48 V 0,5 A 20 VA 40 mm first contact *NO= normally open / NC = normally closed at empty reservoir Included in delivery mounting bolts M5 (6 pieces) and GI cork-gasket Function switching point °C switching point tolerance max. hysteresis NC = open / NO = closed at increasing temperature Other temperatures and designs with 2x TK contacts on request Temperature sensor tolerance Temperature transmitter probe element measuring range operating voltage (UB ) output load W max. last contact Function switching point °C switching point...
Open the catalog to page 2Product code for Nivotemp NT 61-... NT 61- - - - - - A B - C Series Nivotemp NT 61 Design MS brass VA float and immersion tube stainless steel only for double temp. contact C T2 (2nd Temperature contact) NC NO TM50NC TM50NO =50 °C TM60NC TM60NO =60 °C TM70NC TM70NO =70 °C TM80NC TM80NO =80 °C Length (max. 1500 mm) 280 370 500 Variable (please specify length ) Temperature * O Pt 100 = Temperature sensor (RTD) KT = Temperature transmitter TK = Temperature contact N TK50NC = 50 °C NC TK60NC = 60 °C NC TK70NC = 70 °C NC TK80NC = 80 °C NC A Level contact K = NC/NO W = change over *cannot be combined...
Open the catalog to page 3Level contacts max. # function max. voltage max. current max. contact load min. distance of contact current consumption at power up operating current consumption supply voltage (UB ) ambient temperature Temperature sensor *NO= normally open / NC = normally closed at empty reservoir -20 °C to +120 °C 0 °C to 100 °C 1% 0.5 °C IP65 4 digit 7 segment LED display 3 button keypad approx. 100 mA for 100 ms approx. 50 mA 10 - 30 V DC (nominal voltage 24 V DC) -20 °C to 70 °C RTD (Pt 100) class B, DIN EN 60751 Display Temperature display range alarm range accuracy resolution protection class display operation...
Open the catalog to page 4Product code for Nivotemp NT 61D-... NT 61D- O -2T LED Temperature display 2 x Temperature output Design MS brass VA float and immersion tube stainless steel -4T LED Temperature display 4 x Temperature output -1T-KT LED Temperature display 1 x Temperature output 1 x Analogue output Length (max. 1500 mm) 280 370 500 Variable (please specify length) Switch function 2nd contact NO = normally open L NC = normally closed Position L2=...mm 2nd level contact Switch function 1st contact NO = normally open NC = normally closed Position L1=...mm 1st level contact Description Connecting cable M12x1, 1,5...
Open the catalog to page 5max. voltage max. current max. contact load min. distance of contact max. operating temperature *NO= normally open / NC = normally closed at empty reservoir 4 8 with stilling pipe of VA first contact last contact Included in delivery mounting bolts M5 (6 pieces) and GI cork-gasket TK 1 230 V 2.5 A 100 VA Function switching point in °C switching point tolerance max. hysteresis Function switching point in °C switching point tolerance max. hysteresis clearance min. Ø60 min. Ø61 with stilling pipe Temperature contact # of temp. contacts max. voltage max. current max. contact load NO= normally open...
Open the catalog to page 6Product code for Nivotemp NT 61-... NT 61-HT- Series Nivotemp Only for double temp. contact C T2 (2nd Temperature contact) NC NO TM50NC TM50NO =50 °C TM60NC TM60NO =60 °C TM70NC TM70NO =70 °C TM80NC TM80NO =80 °C Design -HT stainless steel Connector M3 S6 M12 2M12 C6F Length (max. 1500mm) 280 370 500 Variable (please specify length) Temperature * Pt 100 = Temperature sensor (RTD) KT = Temperature transmitter N TK = Temperature contact TK50NC = 50 °C NC TK60NC = 60 °C NC A TK70NC = 70 °C NC TK80NC = 80 °C NC # level contacts 1-4 Level contact K = NO/NC K-HT = NO/NC W = change over W-HT = change...
Open the catalog to page 7only level contact(s) only level contact(s) level contact(s) level contact(s) level contact(s) level contact(s) level contact(s) level contact TK/TM = Thermo contact KT = Temperature transmitter PT = Temperature sensor Pt 100 (RTD) other assignment on request we reserve the right to amend specifications
Open the catalog to page 8Display unit Display unit Type NT 61D-4T level contact(s) 4 x Temperature output Type NT 61D-1T-KT level contact(s) 1 x Temperature output 1 x Analogue output Display unit Type NT 61D-2T level contact(s) 2 x Temperature output Note: If the switching output is measured with high-impedance measuring equipment or if the frequency output is used, connect a 10 kW resistor between output and ground to avoid faulty measurements. we reserve the right to amend specifications
Open the catalog to page 96 Pages
2 Pages
7 Pages
6 Pages
6 Pages
7 Pages
8 Pages
434 Pages
394 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
2 Pages
7 Pages
8 Pages
2 Pages
2 Pages
2 Pages
2 Pages
6 Pages
6 Pages
3 Pages
4 Pages
2 Pages
3 Pages
2 Pages
2 Pages
2 Pages