Heated Sample Gas Filter The traditional design of heated particulate filters requires considerable maintenance and down time due to the work required to change the filter media. Buhler's AHF-22 incorporates a new advanced design that eliminates much of this work and sets new standards for ease and speed of maintenance. A spent filter can be changed in seconds and does not require dismantling the unit. Simply turn the handle 90 ° and the filter element slides Depending on the application, the filter can be heated by self-regulating or controller-regulated cartridges. Filter media are available in sintered stainless steel, ceramic . No CO Id or pleated stainless steel. ■ Robust and reliable design ■ Change filter element without tools or ■ Regulated or self-regulating heating ■ Optional calibration gas port Buhler Technologies GmbH Internet: www.buehler-technologies.com e-mail: analyse@buehler-technologies.com
Open the catalog to page 1Technical Data Heating power Protection class Dead volume Filled resin Viton (Perfluorelastomer optional) Temperature sensor Ambient temp. Self-regulated heating: approx. 180°C Self-regulated heating: alarm at 140°C Please indicate with order* Self-regulated , calibration gas port Temperature controller Temperature controller *without filter element "without temperature controller Part no. Material Pore size Package 46222010 Sintered stainless steel 5um 1 pc. 46222011 Pleated stainless steel element 10 urn 1 pc. we reserve the right to amend specification
Open the catalog to page 2All Bühler Technologies catalogs and technical brochures
-
Gas cooler series TC-MINI
6 Pages
-
sample gas probe GAS 222.10
2 Pages
-
Oil/air cooler BLK ATEX-3GD
7 Pages
-
Off-line cooler BNK ATEX-2GD
6 Pages
-
Off-line cooler BNK ATEX-3GD
6 Pages
-
Circular pumps BFP
7 Pages
-
Circular pumps BFP ATEX-2GD
8 Pages
-
Buhler catalogue for Fluid Control
434 Pages
-
Bühler Gas Analysis catalogue
394 Pages
-
Safety Flow Meter S-SM
2 Pages
-
Controllers
2 Pages
-
Flow Meter SM-6
2 Pages
-
Panel Filter AGF - FA - 5
2 Pages
-
Panel Filter AGF - FE 4
2 Pages
-
Panel Filter AGF - FE
2 Pages
-
Sample Gas Filter AGF - T 30
2 Pages
-
display and control unit
2 Pages
-
VSA 24-DM / DH / DP
2 Pages
-
Oil/air coolers BNK
7 Pages
-
BWT platecooler series
8 Pages
-
Capacity sensor VSA 24-SM
2 Pages
-
Nivotemp 61-0 WW series
2 Pages
-
Water alarm WW 6 series
2 Pages
-
GAS 222.20
2 Pages
-
BNF off line filter
6 Pages
-
NV 71
6 Pages
-
NT 67 XP
3 Pages
-
NT 61
9 Pages
-
NT M
4 Pages
-
SM series
2 Pages
-
P 1.1
3 Pages
-
BF 2-S
2 Pages
-
AGF
2 Pages