Catalog excerpts
HIGH ACCURACY (vAoj Budenberg Designed specifically for applications that need a compact high specification pressure transducer. Ideal for applications that need a broad temperature capability combined with an all welded pressure construction. Modular construction allows flexibility with a wide choice of electrical terminations to suit customer requirements. Field proven polysilicon thin film bridge technology gives a very stable and high performance ± 1 % total error band, over The sensor is electron beam welded to stainless steel pressure fitting ensuring excellent overpressure capability and durability where shock and vibration are present. Performance Specifications Reference Conditions Total Error Band : including non-linearity, hysteresis, non- repeatability, and temperature error (see table) Tighter accuracy performance available on request Non-linearity : Less than ±0.1 % of span typical (B.F.S.L.) Non-repeatability : Less than ±0.03%% of span typical Stability : Less than ±0.25% span /year Durability : Tested to 50 million cycles Vibration : Random vibration (20g) over temperature range Drop Test : Withstands 1 metre on concrete, 3 axis Response time : Less than 1 msec Position effect : Less than ±0.01% span, typical rjrcr limila at MA pciiüi |^L(K Al i*TQ4l Physical Specifications Pressure connections : 304 Stainless Steel Housing : 20% Glass reinforced nylon, fire retardant to UL94 V1 Sensor Material : 17-4PH Stainless Steel Sensor Type : Polysilicon thin film bridge Connection sizes : 1/8"NPT, 1/4" NPT, 1/4 BSP Male Electrical Connections Shielded cable, 1 metre standard Flying leads, 1 metre standard Certificate of conformity supplied Annex A (Heavy Industrial) and including P.E.D. Standard Ranges Please consult our Sales Department for additional pressure ranges,
Open the catalog to page 1MINI HIRSCH-MANH" Goiinedortir similar FLYIiiG LEADS SHIELDED CABLES Electrical Specifications Output signals availability :- Ratlometrlc Output Current Output Circuit protection : Reverse polarity & miswire protected. Insulation Breakdown Voltage :100 VC Insulation Resistance : greater than 100 megohms @ 100 VDC Power Supply Voltage vs. Loop Resistance Loop Supply Voltas* (Vdo) To Determine minimum loop supply voilage: LSV= Loop Supply Voltage (Vdc) RL = Loop Resistance (ohms) BE - Sense Resistance (ohms) (Measuring Instrument! R„, = Wiring Resistance (ohms) The PT2 has been designed to...
Open the catalog to page 2All Budenberg catalogs and technical brochures
-
BGL-DPT1000
2 Pages
-
Watertight Pressure Gauge
2 Pages
-
Large Dial Oxygen Gauge
2 Pages
-
Diaphragm Differential
2 Pages
-
Diaphragm Seal
6 Pages
-
Bi-Metallic Thermometers
2 Pages
-
Thermowells
2 Pages
-
Standard Process Gauge
2 Pages
-
Lower Cost Process Gauge
2 Pages
-
PNEUMATIC VALVE POSITIONER
2 Pages
-
BALL VALV E PROCESS INDUSTRY
2 Pages
-
6N, 10N
2 Pages
-
6MN, 10MN
3 Pages
-
V100E-IS
2 Pages
-
Model MVF
2 Pages
-
V1OOP
2 Pages
-
Model 98F
2 Pages
-
Model MVS
2 Pages
-
Model 98S
2 Pages
-
Model 93
2 Pages
-
Model 6MBB
3 Pages
-
Model 6MNB
3 Pages
-
Model 6M
3 Pages
-
Model 6MNBB
3 Pages
-
Model 62NR (Female Process)
2 Pages
-
Model 6MN
3 Pages
-
Model 63NR
2 Pages
-
Model 65NR
2 Pages
-
Model 62NR (Male Process)
2 Pages
-
Model 10Bb
2 Pages
-
Model 6Bb
2 Pages
-
Model 6N
2 Pages
-
VAC Products Range
12 Pages
-
Gauges Products Range
10 Pages
-
D300
2 Pages
-
V100E
2 Pages
-
Check Valves
2 Pages
-
6MN Single Block
3 Pages
-
93 Bar Stock DBB
2 Pages
-
63NR 3 Way Manifold Female
2 Pages
-
62NRM 2 Way Manifold Male
2 Pages
-
Ball Valves
2 Pages
-
Needle Valves
2 Pages
-
Adjustable Snubber
2 Pages
-
DX Digital Test Gauge
2 Pages
-
766GP Supasafe
2 Pages
-
5214 0.25% Test Gauge
2 Pages
Archived catalogs
-
Complete application notes
162 Pages