PT2 OEM Pressure Transducer
2Pages

{{requestButtons}}

Catalog excerpts

PT2 OEM Pressure Transducer - 1

HIGH ACCURACY (vAoj Budenberg Designed specifically for applications that need a compact high specification pressure transducer. Ideal for applications that need a broad temperature capability combined with an all welded pressure construction. Modular construction allows flexibility with a wide choice of electrical terminations to suit customer requirements. Field proven polysilicon thin film bridge technology gives a very stable and high performance ± 1 % total error band, over The sensor is electron beam welded to stainless steel pressure fitting ensuring excellent overpressure capability and durability where shock and vibration are present. Performance Specifications Reference Conditions Total Error Band : including non-linearity, hysteresis, non- repeatability, and temperature error (see table) Tighter accuracy performance available on request Non-linearity : Less than ±0.1 % of span typical (B.F.S.L.) Non-repeatability : Less than ±0.03%% of span typical Stability : Less than ±0.25% span /year Durability : Tested to 50 million cycles Vibration : Random vibration (20g) over temperature range Drop Test : Withstands 1 metre on concrete, 3 axis Response time : Less than 1 msec Position effect : Less than ±0.01% span, typical rjrcr limila at MA pciiüi |^L(K Al i*TQ4l Physical Specifications Pressure connections : 304 Stainless Steel Housing : 20% Glass reinforced nylon, fire retardant to UL94 V1 Sensor Material : 17-4PH Stainless Steel Sensor Type : Polysilicon thin film bridge Connection sizes : 1/8"NPT, 1/4" NPT, 1/4 BSP Male Electrical Connections Shielded cable, 1 metre standard Flying leads, 1 metre standard Certificate of conformity supplied Annex A (Heavy Industrial) and including P.E.D. Standard Ranges Please consult our Sales Department for additional pressure ranges,

Open the catalog to page 1
PT2 OEM Pressure Transducer - 2

MINI HIRSCH-MANH" Goiinedortir similar FLYIiiG LEADS SHIELDED CABLES Electrical Specifications Output signals availability :- Ratlometrlc Output Current Output Circuit protection : Reverse polarity & miswire protected. Insulation Breakdown Voltage :100 VC Insulation Resistance : greater than 100 megohms @ 100 VDC Power Supply Voltage vs. Loop Resistance Loop Supply Voltas* (Vdo) To Determine minimum loop supply voilage: LSV= Loop Supply Voltage (Vdc) RL = Loop Resistance (ohms) BE - Sense Resistance (ohms) (Measuring Instrument! R„, = Wiring Resistance (ohms) The PT2 has been designed to...

Open the catalog to page 2

All Budenberg catalogs and technical brochures

  1. BGL-DPT1000

    2 Pages

  2. Thermowells

    2 Pages

  3. 6N, 10N

    2 Pages

  4. 6MN, 10MN

    3 Pages

  5. V100E-IS

    2 Pages

  6. Model MVF

    2 Pages

  7. V1OOP

    2 Pages

  8. Model 98F

    2 Pages

  9. Model MVS

    2 Pages

  10. Model 98S

    2 Pages

  11. Model 93

    2 Pages

  12. Model 6MBB

    3 Pages

  13. Model 6MNB

    3 Pages

  14. Model 6M

    3 Pages

  15. Model 6MNBB

    3 Pages

  16. Model 6MN

    3 Pages

  17. Model 63NR

    2 Pages

  18. Model 65NR

    2 Pages

  19. Model 10Bb

    2 Pages

  20. Model 6Bb

    2 Pages

  21. Model 6N

    2 Pages

  22. D300

    2 Pages

  23. V100E

    2 Pages

  24. Check Valves

    2 Pages

  25. Ball Valves

    2 Pages

Archived catalogs