The Marine Survey Kit includes a weighted silver/silver chloride half-cell, a plastic cable spool, and a multimeter for conducting corrosion surveys on marine structures. The half-cell is housed in a PVC body with water flow holes and is connected to the cable spool by a CSP 55/015 cable.

Technical Data
Multimeter: 3½ Digit LCD, DC/AC Voltage & Current Ranges, DC Accuracy: ± 0.5%, AC Accuracy: ± 1.2%.
Half-cell: Size: 140mm x 25mm, Output: ≈ +250mV VS SHE, Temperature coefficient: -0.6mV/°C, Temperature range: 0 - 30 °C.

Unpacking
The kit includes a multimeter, a weighted half-cell on a cable spool, and leads for connection.

Operation
Before use, soak the half-cell in seawater for 2 hours. Connect the leads to the multimeter and cable spool, and test the setup by immersing the crocodile clip in water to check for a reading change.

Surveying
Decide survey locations and ensure consistent conditions. Lower the half-cell to the desired depth, connect to the structure, and record the corrosion potential displayed on the multimeter.

Storage
For long-term storage, clean and dry the components, remove batteries, and store in a cardboard box.

Calibration
Check the multimeter against another meter and a 1.5V battery. Verify the half-cell against a K-SAT reference cell for accuracy.

Disposal Information
Dispose of the product according to UK WEEE regulations or local guidance.

Contact Details
Manufacturer: Buckleys (UVRAL) Ltd, Address: Buckleys House, Folkestone, Kent, UK, Tel: +44 (0)1303 278888, Website: www.buckleysInternational.com
See more

Catalog excerpts

User Manual: Marine Survey kit-1

Marine Silver/Silver chloride reference cell/ Survey Kit Operating Instructions English Version Please read carefully before use

 Open the catalog to page 1
User Manual: Marine Survey kit-3

Marine Silver/Silver chloride reference cell/ Survey Kit Description The Marine Survey Kit comprises a weighted silver/silver chloride half-cell, plastic cable spool and an accurate multimeter. The kit has been specially created to include all items required to easily carry out a corrosion survey of marine structures. The half-cell is housed in a PVC body with holes to allow the easy flow of water across the cell. The half-cell is weighted to help keep it in position. The cell is connected to the cable spool by CSP 55/015 cable 75m of cable (6004-0044) or 150m lead on a reel (6004-0093). The...

 Open the catalog to page 3
User Manual: Marine Survey kit-4

Instruction Manual Unpacking The Marine Reference Cell comprises: • 1 x Silver/Silver Chloride reference cell (12.5m or 25m non-weighted) The Marine Survey Kit comprises: ● 1 x Multimeter with operating instructions (Note: copies cannot be supplied) 1 x Silver/Silver Chloride weighted half-cell on a cable spool 1 x Black lead with a 4mm plug on each end 1 x Red lead with a 4mm plug on one end and a crocodile clip on the other If the half-cell is new or has not been used for a long time it should be soaked in a plastic bucket of clean seawater for about 2 hours. It may need longer if the half-cell...

 Open the catalog to page 4
User Manual: Marine Survey kit-5

Marine Silver/Silver chloride reference cell/ Survey Kit Surveying Decide where on the structure the readings are to be taken. For consistency the reading should be taken in the same place at the same state of the tide, if applicable, and at the same depth. This will allow changes to be readily spotted. Always consult a corrosion engineer to interpret the results. i. Lower the half-cell into the water to the required depth. Connect the crocodile clip to the structure making sure there is a good bare metal connection. Switch the multimeter to the 2 volt (2000mV) DC range and the corrosion potential...

 Open the catalog to page 5
User Manual: Marine Survey kit-6

Instruction Manual Fit new batteries into the multimeter, see instructions supplied. Soak the half-cell in a plastic bucket of clean sea water for about 2 hours. It may take longer if the half-cell has not been used for a long time. Connect the black lead to the cable spool and to the terminal marked ‘Com’ (- terminal) on the multimeter. Connect the red lead with the crocodile clip to the terminal marked ‘V’ (+ terminal) on the multimeter. vi. Switch the multimeter to the 2 volt (2000mV) DC range (see instructions supplied with meter). vii. With the half-cell still in the bucket of sea water,...

 Open the catalog to page 6
User Manual: Marine Survey kit-7

Marine Silver/Silver chloride reference cell/ Survey Kit Contact Details Manufacturer: Buckleys House Unit G, Concept Court Shearway Business Park Shearway Road Folkestone Kent CT19 4RG, UK Distributor details

 Open the catalog to page 7

All Buckleys (UVRAL) Limited catalogs and technical brochures

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.