Quick start guide: Pool Pro2 - swimmingpool leak detector kit
2Pages

{{requestButtons}}

Catalog excerpts

Quick start guide: Pool Pro2 - swimmingpool leak detector kit - 1

Risk Assessment IMPORTANT: Do not use with a pacemaker, cochlear implant, or a trans-dermal electronic implant e.g., glucose monitor. If contact with the test electrode is unavoidable consider wearing The operator should be in good health and - in particular - not suffer rubber or plastic insulating gloves. from any cardiac condition. Instrument Settings The user should establish, in conjunction with their client, and having regard for the material being tested, appropriate test conditions to be applied. In the absence of a customer specification, Buckleys has found NACE SP0274 to be a useful general-purpose standard, however, it remains the user’s responsibility to establish safe and reliable testing conditions. POOL PR02Quick Start GuideSafety Warnings Make sure you complete a risk assessment before using Buckleys equipment. The following points offer some guidance: Personal Safety • Are users fully trained? • Are users aware of the risk of electric shock? • Are the instrument and accessories in good condition, undamaged and dry? • Does anyone have a pacemaker, cochlear implant or trans-dermal implant? If so, can you keep them away? • Do you have sufficient ventilation? • Do you have a safe access route to the site? Is fall protection necessary? If so, is it in place? • Has the instrument been properly grounded to a metallic grounding point? • Should you use the anti-static wristband to prevent static charge build-up? Explosion & Fire Risk • Are you certain that there is no risk of an explosive atmosphere? • Have all flammable materials been removed from the work area? EMC & RFI • Buckleys high-voltage instruments will produce sparks which may cause radio interference. • Is there any risk of causing a danger to others - e.g., medical or life support equipment? • Is there any risk of causing costs or inconvenience to others - e.g., industrial processes, measuring equipment, scientific apparatus, domestic radio and TV? Other Risks • Have you checked that there are no ongoing processes in the area that may be dangerous - X-ray machines, or other radiation? • Are you certain that the instrument has not been immersed in liquid, dropped or otherwise damaged in a way that is not obvious? • Have you verified that the ground connection is actually grounded? • Is the person responsible for site safety aware of / fully understanding the testing you are going to do, and has it been reviewed in line with the site procedures? NOTE: Wherever you are intending to use equipment of this type, on your site or on a customer's, always obtain clearance from the site's safety officer. Buckleys (UVRAL) Ltd. Buckleys House, Unit G, Concept Court, Shearway Business Park, Shearway Road, Folkestone, Kent. CT19 4RG. UK Tel: +44 (0)1303 278888 Email: sales@buckleys.co.uk Website: www.buckleysinternational.com

Open the catalog to page 1
Quick start guide: Pool Pro2 - swimmingpool leak detector kit - 2

Quick Start Guide Setup 1 PUSH plug into socket DO NOT turn or twist! a Battery level indicator b Menu symbol c Voltage currently applied to electrode d Current draw at electrode e Output lock ON/OFF f Sensitivity threshold g Set test voltage h Sensitivity threshold graph i Handle temperature PUSH plug into socket DO NOT turn or twist! Instrument working? Online Reference Guide 1. Press the ON button. 2. Touch the electrode to a suitable conductive grounded item. 3. The alarm should sound. Scan the code, scroll down the page and click on the Reference Guide tab. 25 - 50mm Press and hold the...

Open the catalog to page 2

All Buckleys (UVRAL) Limited catalogs and technical brochures