Safety Warnings:
  • Individuals with pacemakers or electronic implants should avoid using this high-voltage equipment.
  • Do not operate in combustible atmospheres or ATEX Hazardous Areas.
  • Only trained personnel should operate the equipment.
  • Ensure the instrument is grounded before applying high voltage.
  • Avoid using the equipment if it has been immersed in water.
Declarations of Conformity:
  • The product complies with EU directives 2014/30/EU, 2014/35/EU, 2015/863/EU, and 2011/65/EU (RoHS).
  • It also adheres to UK legislation on electronic compatibility and safety regulations.
Specifications:
  • Output voltage range: 0.9kV – 40kV.
  • Max output current: <1mA.
  • Alarm sensitivity range: 10μA to 450μA.
  • Recommended coating thickness: 13μm – 25.6mm.
  • Battery type: 4 x D-cell/LR20 with 8 hours battery life.
Maintenance:
  • Regular cleaning of the unit is recommended.
  • Annual calibration by an approved provider is required.
Register Your Product:
  • Register on Buckleys’ website for service reminders and updates.
Kit Contents:
  • Includes main detector unit, test probe handle, electrodes, batteries, charger, and more.
Risk Assessment:
  • Ensure all users are trained and aware of the high voltage risks.
  • Check for explosive atmospheres and ensure proper grounding.
Factory Settings:
  • Output voltage: 10kV, Alarm suppression: 0, Sensitivity: 200μA.
Overview: This document provides instructions for setting up and operating a testing instrument, including configuring language, voltage, sensitivity, alarm suppression, and test thickness settings. It also includes a quick start guide and contact information for the manufacturer.
Specifications and Procedures:
  • Setting Interface Language: Access the main settings menu, navigate to 'Set Language', select the desired language, and return to the main display.
  • Setting Output Voltage: Access the main settings menu, navigate to 'Adjust Voltage', select the desired voltage, and return to the main display.
  • Setting Sensitivity Threshold: Access the main settings menu, navigate to 'Adjust Sensitivity', select the desired threshold, and return to the main display.
  • Setting Alarm Suppression: Access the main settings menu, navigate to 'Alarm Suppression', select the desired suppression level, and return to the main display.
  • Setting Test Thickness via a Standard: Access the main settings menu, navigate to 'Test Standard', select the desired standard, input the test material thickness, and observe the calculated test voltage.
Recommendations:
  • Establish appropriate test conditions in conjunction with the client, considering the material being tested.
  • In the absence of a customer specification, NACE SP0274 is recommended as a general-purpose standard.
  • Initial sensitivity setting of 350μA and suppression setting of 7 are recommended, but should be optimized based on testing conditions.
Testing Procedure: Test the instrument by holding the ON button on the test probe handle and briefly placing the electrode in contact with a conductive, grounded item to trigger the alarm system.
Contact Information: Manufacturer: Buckleys (UVRAL) Ltd., Address: Buckleys House, Unit G, Concept Court, Shearway Business Park, Shearway Road Folkestone, Kent CT19 4RG, UK, Tel: +44 (0)1303 278888, Email: [email protected], Website: www.buckleysinternational.com
See more

Catalog excerpts

Quick start guide: Dry Roof Pro2-1

Electronic Flat Roof Leak Detection and Location Kit Quick Start Guide Please read this guide before using the equipment

 Open the catalog to page 1
Quick start guide: Dry Roof Pro2-3

Safety Warnings IMPORTANT: We strongly advise that individuals with pacemakers, cochlear implants, or trans-dermal electronic implants e.g., glucose monitors do not use our highvoltage test equipment under any circumstances. IMPORTANT: This product must not be used in combustible atmospheres or ATEX Hazardous Areas, such as fuel stations or in proximity to any combustible gas (and/ or oxygen concentrations exceeding normal atmosphere). All high-voltage testing equipment must be operated by suitably trained, responsible, authorised personnel only. IMPORTANT: This product can cause radio interference...

 Open the catalog to page 3
Quick start guide: Dry Roof Pro2-4

Quick Start Guide EC Declaration of Conformity We, Buckleys (UVRAL) Ltd., as sole manufacturer of the apparatus listed below, declare that the product Dry Roof Pro2 is manufactured in conformity with the following directives: 2014/30/EU, 2014/35/EU, 2015/863/EU and 2011/65/EU (RoHS). Date: 01/07/2021 Authorised by: J P Hoveman CEO, Buckleys (UVRAL) Ltd. UKCA Declaration of Conformity We, Buckleys (UVRAL) Ltd., as sole manufacturer of the apparatus listed below, declare that the product Dry Roof Pro2 is manufactured in conformity with the following UK legislation: Electronic Compatibility Regulations...

 Open the catalog to page 4
Quick start guide: Dry Roof Pro2-5

Maintenance The Dry Roof Pro2 is designed for minimum maintenance by the user, however the following periodic checks/actions are recommended: The exterior of the unit should be cleaned regularly. Stubborn dirt may be removed with a moistened cloth (99% water +1% mild detergent). Mild solutions may be used to remove greasy dirt. Do not allow cleaning fluid to enter the unit. The use of other cleaning agents may lead to damage to the detector’s surface areas. Our service team will ensure your detector’s performance is within our strict tolerances and carry out a thorough inspection of the entire...

 Open the catalog to page 5
Quick start guide: Dry Roof Pro2-6

Quick Start Guide Kit Contents Upon delivery of your Dry Roof Pro2, please take the time to ensure that the kit is complete, and all components shown below are present and undamaged: Main detector unit Test probe handle and nosecone Interconnecting lead Electrostatic discharge wristband Calibration certificate 150mm stainless steel drum brush electrode 5m earth cable on reel D-cell rechargeable batteries x4 Battery charger with mains power adaptors and in-car charger* 450mm angled phosphor-bronze brush electrode Pair of knurled locknuts Pointed probe electrode Padded carry bag with shoulder strap...

 Open the catalog to page 6
Quick start guide: Dry Roof Pro2-7

Risk Assessment It the user’s responsibility to complete a risk assessment before using Buckleys equipment. The following points offer some guidance but must not be assumed to be complete or sufficient. Personal safety • Have all users been trained in the correct and safe use of the instruments? • Are they aware that the instrument produces high voltages, and can give electric shocks if used incorrectly? • Is the instrument in good condition, undamaged? Is the instrument dry? Are the accessories similarly in good condition, dry and undamaged? • Is it possible to ensure that persons with pacemakers,...

 Open the catalog to page 7
Quick start guide: Dry Roof Pro2-9

Setup (continued) Instrument settings Switch the instrument on by pressing a. The screen displays the following information (see fig.8): a Battery level indicator b Menu symbol c Voltage currently applied to electrode d Current draw at electrode e Output lock ON/OFF f Sensitivity threshold g Set test voltage h Sensitivity threshold graph i Handle temperature Setting interface language Press b to access the main settings menu and press d or e to scroll to Set Language and press b. Press d or e to scroll to the desired language and press b. Press c to return to the main display screen. Setting...

 Open the catalog to page 9
Quick start guide: Dry Roof Pro2-10

Quick Start Guide Basic Testing Press and hold the ON button

 Open the catalog to page 10
Quick start guide: Dry Roof Pro2-11

Basic Testing (continued)

 Open the catalog to page 11
Quick start guide: Dry Roof Pro2-12

Contact Details Manufacturer Address Buckleys House Unit G, Concept Court, Shearway Business Park, Shearway Road Folkestone, Kent CT19 4RG, UK Tel: +44 (0)1303 278888 Email: [email protected] www.buckleysinternational.com

 Open the catalog to page 12