Cecil 2000 & 3000 Catalog - 1

ORDERING SPECIFICATIONS HIGHLIGHTS SPECIFICATION TIONS Monochromator Optical Bandwidth Wavelength Range Wavelength Accuracy Wavelength Reproducibility Self Test and Calibration Straylight Display Screen - LCD Display Scrolling Autozero Photometric Ranges Photometric Accuracy Photometric Noise Stability Multi-Wavelength Analysis Assay Program Littrow, 1200 lines/mm holographic grating 4nm - Aurius; 1.8nm Super Aurius 190-1000nm; 325-1000nm visible versions Better than ±1nm 0.1nm Automatic at switch on Typically less than 0.01% at 220 and 340nm High resolution backlit with contrast control Provides 6 screen widths for viewing plots etc. Automatic by press button Digital display of -0.3-3A, 0-200%T, 0-9999C ±0.005A or 1% whichever is greater Less than ±0.00004A (500nm RMS) Better than 0.001A/hour at constant temp. 2 and 3 wavelength methods Enter multi-wavelength formula for automatic computation and formatting of any assay Curve Fitting and Editing Linear, quadratic or cubic; up to 30 standards Cell and Wavelength Programming Up to 8 cells and 10 wavelengths combined Up to 30 methods stored in protected memory Method Storage Absorbance Ratioing 260/280nm or any two selected wavelengths Peak Seek Automatic search, baseline corrected Reaction Kinetics Tabulated results, reaction plots, reprocessing Batch Sampling 100 samples, internal control, screen display Real Time Clock Timed and dated reports Computer/printer interfaces Bi-directional serial RS232 and parallel ports Sample Temperature Displayed and set from keyboard Size 480 x 340 x 205mm Weight 16.8kg Visible; 18.6kg UV; + 0.9kg with printer Power Requirements 110-250V, 50/60Hz; 120W/170W UV versions SUPER AURIUS ADDITIONAL SPECIFICATION BENEFITS High Performance Scans SUPER AURIUS ADDITION Derivative Spectra Time Plots Assay Formula Program DataStream - Fast Data to PC Display Scrolling - 6 Screens Wide E-SEF Software Call-up Integral Printer Versions Method Storage SPECIFICATIONS HIGHLIGHTS Cell and Wavelength Programs Kinetics, Single/Multi-cell Multi-Wavelength Assays UV Lamp 1500 Hour Guarantee SUPER AURIUS ADDITIONAL SPECIFICATION Self Test and Calibration Optical Bandwidth Wavelength Scanning and Range Wavelength Scale Expansion Scan Speed Photometric Plotting Ranges Baseline Flatness Overlayed Spectra Spectral Reprocessing Dynamic Scan Recall Spectral Storage Derivative Spectra Multi-cell Kinetics Band Quantification Time Course Plotting 1.8nm 1-4000nm/min; 190-1000nm Selectable by keyboard entry 1-100nm/cm Selectable by keyboard entry 1-4000nm/min Keyboard entry of limits; or automatic optimum Better than ±0.002A (300nm/min) most of range Up to 6 Spectra and derivatives with or without offsets Spectra manipulated and replotted over any range Instant, automatic recall of last 8 scans Up to 100 spectra may be stored security code protected 1st and 2nd derivatives Up to 4 or 6 cells, with with plots and reprocessing Automatic band area and height correction Plots may be reprocessed and stored Cecil Instruments policy is one of continuous development. We therefore reserve the right to change specification without notice. Compact - Only 48cm Wide PERFORMANCE Optical Bandwidth 1.8nm Straylight 0.01% Wavelength Precision 0.1nm Stability ±0.001 A/hour Accurate to 3A Full Validation Procedures CECIL INSTRUMENTS LIMITED MILTON TECHNICAL CENTRE ISO 9000 CAMBRIDGE CB4 6AZ ENGLAND CERTIFIED COMPANY TEL: 01223 420821 FAX: 01223 420475 E-MAIL: info@cecilinstruments.com WEBSITE: www.cecilinstruments.com

Open the catalog to page 1
Cecil 2000 & 3000 Catalog - 2

ROUTINE / RESEARCH UV-VISIBLE SPECTROPHOTOMETERS

Open the catalog to page 2
Cecil 2000 & 3000 Catalog - 3

AURIUS - The Choice - SUPER AURIUS Aurius Series Super Aurius Series With an optical bandwidth of 4nm and superb stability, accuracy and precision these very easy to use instruments are ideal general purpose spectrophotometers. Excellent for routine and quality control laboratories, they offer a wide range of techniques with wavelength scanning as an option. Both UV and Visible versions are available with full validation procedures. The Super Aurius instruments are unique for their very high performance scanning, with derivatives, overlay, extended analytical power and multi-cell Kinetics....

Open the catalog to page 3
Cecil 2000 & 3000 Catalog - 4

AURIUS - The Choice - SUPER AURIUS SIX SCREEN WIDTH VIEWING Accurate Quantification FAST : EASY TO USE : POWERFUL SOFTWARE For optimum accuracy when measuring concentration, a calibration line may be fitted to a series of up to 30 standards or replicates. Accuracy is improved over using a single known concentration. FAST PROGRAM ANY ASSAY Concentration Curve Fitting When concentration is not linearly related to absorbance a quadratic or cubic curve FOR MORE POWER - PERFORMANCE FAST DATA TRANSFER TO PC may be fitted to up to 30 standards or replicates, with or without an intercept. A...

Open the catalog to page 4
Cecil 2000 & 3000 Catalog - 5

SIX SCREEN WIDTH VIE FAST : EASY TO USE : AST SCANNING NOTE: This column applies only to Super Aurius. Scan is an option on the Aurius range. Wavelength Scan Scans at up to 4000nm/min are presented on screen or printed with all peaks annotated with wavelength and absorbance. Tables are also presented listing all peaks and troughs with values. Derivative Spectra Derivative spectra are readily produced, with selectable smoothing, either alone or superimposed on the fundamental, with or without an offset. Scaling is automatic, with all peaks and troughs quantified. Overlayed Spectra Up to six...

Open the catalog to page 5
Cecil 2000 & 3000 Catalog - 6

: POWERFUL SOFTW SOFTWARE ASSAY SYSTEM FUNCTIONS PERFORMANCE DataStream - Fast Data Transfer and Control Cecil DataStream software provides fast transfer of all data to a PC for incorporation into a spread sheet or mathematical package of the users choice. Fast and easy to use. Spectrophotometers may also be controled from the PC. DATION :and Calibration Self Test GLP An automatic test procedure, at switch-on, checks all instrument functions and calibrates wavelength against a deuterium lamp emission line. Performance is confirmed by a timed and dated report including instrument serial...

Open the catalog to page 6
Cecil 2000 & 3000 Catalog - 7

Fast Program Any Assay Any quantitative assay may be rapidly input for automatic computation using the Cecil Assay Program software module. No programming skill is required by the operator. Transcription and calculation errors are avoided and validation is simple as no PC is used. Calculations for a series of Carboxy Haemoglobin samples is shown below with the formulae used. Assay Program Complex assays only require text entry of any formula with up to 76 characters. For complex calculations up to 20 such formulae may be entered and linked for formidable computing power without a PC. cells...