GSC53N

GSC53N
1 / 10 PagesView full catalog

GSC53N

Product catalog summary
Overview: The GSC53N is a multifunction tester and three-phase power analyzer by HT ITALIA, designed for electrical installation testing and power quality analysis, adhering to standards like IEC 61557, VDE 0100, and BS7671.
Key Features:
  • Predefined power quality recordings, including EN50160, voltage anomalies, harmonics, start-up, and power & energies.
  • Flexible clamp transducers with integrated control logic to avoid battery replacement.
  • High-resolution LINE/LOOP impedance and prospective short circuit current measurements with the optional IMP57 accessory.
Functions:
  • Continuity test on protective conductors with 200mA test current.
  • Insulation resistance testing with various DC voltages.
  • RCD tripping time and current measurements.
  • Line and loop impedance measurements with high resolution.
  • Earth resistance and ground resistivity measurements.
  • Phase rotation and power quality tests according to EN50160.
  • Harmonic analysis up to the 49th harmonic.
  • Environmental parameter measurements including temperature, humidity, illumination, and noise.
Accessories:
  • Includes cables, clamps, software, and carrying bag.
  • Optional accessories for noise, temperature, humidity, and lux measurements.
Standards:
  • Complies with CE mark, EN 61326 EMC standards, and various IEC and EN standards for electrical testing and safety.
Electrical Specifications:
  • Detailed accuracy and resolution specifications for continuity, insulation resistance, RCD tripping, line impedance, and more.
  • Voltage and frequency measurement capabilities.
General Specifications:
  • Single/three-phase recording capabilities with extensive memory and display features.
  • Power supply via batteries or external adapter.
  • Mechanical dimensions and environmental operating conditions.
Contact Information: BST Caltek Industrial Ltd., Hong Kong. Email: [email protected], Tel: (852) 2401-1222.
Specifications:
  • Insulation: Double insulation (SS 2)
  • Pollution Degree: 2
  • Over-voltage Category: CAT II 600V AC / 350V AC (to ground); CAT III 600V AC / 300V AC (to ground)
  • Usage: Internal use; Maximum altitude: 2000 meters
  • EMC Compliance: EN61326-1 (1998) + A1 (1999)
  • CE Marking: This instrument complies with the directive for CE marking
See more

Catalog excerpts

GSC53N-1

GSC53N Multifunction Tester and Three-phase Power Analyzer GSC53N is strong evolution equipment developed by HT ITALIA to perform complete test and verify on electrical installations according to the most common safety standards (IEC 61557, VDE 0100 and BS7671) and for power quality analysis on general electric networks. This meter, sure, with high accuracy, dedicated to each proof technician, is a very user-friendly instrument thanks to the followed new integrated features: - Setting up to 5 predefined recordings on power quality (EN50160, Voltage Anomalies, Harmonics, Start-up and Power & Energies) for a easier and rapid analysis of the most common situation on plants. - Use of flexible clamp transducers with integrated control logic. In this way disappear the problem of replace batteries of power adaptor typical of transducers with external control logic. GSC53N model can perform LINE/LOOP Impedance and prospective short circuit current measurements with high resolution (0.1 mΩ) with use of IMP57 optional accessory. In this way is possible realize important measures strictly nearly to power transformer. Due to our policy of continual product development we reserve the right to amend the specifications of all mentioned products without notice. Created on 10/19/2012 12:11:09 PM Prepared by JIM Page 1 of 10

 Open the catalog to page 1
GSC53N-2

HTCaltek Functions • • • • • • • • • • • • • • Continuity test on protective conductors PE with 200mA test current Insulation resistance Tripping time and current of RCDs (type A, AC, general and selective) Line and Loop impedance with calculation of the prospective short circuit current and test of co-ordination of the protections in TN systems Line and Loop impedance with high resolution (0.1mΩ) with IMP57 optional accessory Loop resistance without tripping out of RCDs Earth resistance and ground resistively Phase rotation Power quality tests according to EN50160 Measurement and recording of...

 Open the catalog to page 2
GSC53N-3

Portable calibrator for HT55 probe (CB-5) Transducer for Temperature/Humidity measurements (HT52/05) Transducer for Lux measurements (HT53/05) Kit of strap and hooks to hang the instrument on the neck (CN0050) Clamp 1-100-1000A/1V for leakage currents measure (Ø 54mm) (HT96U) Clamp 10-100-1000A/1V for AC current (Ø 54mm) (HT97U) Case 3x1-5A/1V for connection to TA (HT903) Accessory for Loop Impedance measure at high resolution (0.1mΩ) (IMP57) Standards CE mark EN 61326 EMC Standards EN 50160 IEC 60439-1 Type-tested assemblies TTA and partially type-tested assemblies PTTA EN 61008 EN 61009 EN...

 Open the catalog to page 3
GSC53N-4

HTCaltek 1. ELECTRICAL SPECIFICATIONS – VERIFY TESTS readings + no. of digits) at 23°C CONTINUITY TEST ON PROTECTIVE AND EQUALIZING CONDUCTORS Range (Ω) Resolution (Ω) 0.01 - 9.99 0.01 10.0 - 99.9 0.1 (*) after cable calibration (which eliminates the cable resistance). Test current: > 200mA DC for R ≤ 5Ω(included calibration) Resolution on current measurement: 1mA Open-circuit voltage: 4V ≤ V0 ≤ 24V Open-circuit voltage: < 1.3 x nominal test voltage Short circuit current: < 6.0mA at 500V test voltage Nominal test current: > 2.2mA on 230kΩload (500V); >1mA su 1kΩper Vnom (others) Measurement limits...

 Open the catalog to page 4
GSC53N-5

HTCaltek TRIPPING CURRENT OF RCDS RCD type I∆N AC I∆N ≤ 10mA A AC A A (0.5 I∆N > 10mA 2.0)I∆N A CONTACT VOLTAGE UT Range (V) 0 -2Utlim LINE IMPEDANCE (Phase-Phase, Phase-Neutral) Range (Ω) Resolution (Ω) 0.01 -9.99 0.01 10.0 -199.9 0.1 (*) 0.1 mΩ on range 0.0 -199.9 mΩ(with IMP57 optional accessory) Maximum peak current: 3.65A (at 127V); 6.64A (at 230V); 11.5A (at 400V) Test voltage: 100-265V (Phase-Neutral) / 100-460V (Phase-Phase); 50Hz ±0.5Hz (*) 0.1 mΩ on range: 0.0 - 199.9mΩ (with IMP57 optional accessory) Maximum peak current :3.65A (at 127V); 6.64A (at 230V) Test voltage: 100-265V (Phase-Ground);...

 Open the catalog to page 5
GSC53N-6

HTCaltek VOLTAGE (RCD, LOOP, Phase Sequence) Range (V) 15 – 460 2. ELECTRICAL SPECIFICATIONS – ANALYZER AND AUX Accuracy is indicated as ± (% readings + no. of digits) at 23°C ± 5°C, con relative humidity <60%UR. VOLTAGE – SINGLE PHASE / THREE PHASE SYSTEMS (Auto range) Range (V) Resolution (V) Accuracy 15 -310 0.2 ±(0.5%rdg + 2dgt) 310 -600 0.4 Input Impedance 300 kΩ(Phase-Neutral) 300 kΩ(Phase-Phase) VOLTAGE ANOMALIES – SINGLE / THREE PHASE SYSTEMS (Manual range) Resolution Voltage Range (V) Time Resolution Accuracy Voltage (V) 15 -310 0.2 10ms ±(1.0%rdg + 2dgt) 30 -600 0.4 Input Impedance:...

 Open the catalog to page 6
GSC53N-7

LEAKAGE CURRENCY (by Optional Clamp Transducer) Resolution (mA) Accuracy Range (mA)* ±(5.0%rdg + 0.5 - 999.9 0.1 2dgt) Input Impedance Overload protection (*) While recording the instrument stores only current values > 5mA with 1mA resolution Maximum stored value is the peak value calculated with response time of 1ms HARMONICS - SINGLE / THREE PHASE SYSTEMS Range Maximum resolution DC -25ª 26 ª -33 ª 0.1V / 0.1 A 34 ª -49 ª Due to our policy of continual product development we reserve the right to amend the specifications of all mentioned products without notice. Created on 10/19/2012 12:11:09...

 Open the catalog to page 7
GSC53N-8

(*) Accuracy of HT53 luxmeter probe is according to Class AA Due to our policy of continual product development we reserve the right to amend the specifications of all mentioned products without notice. Created on 10/19/2012 12:11:09 PM Prepared by JIM Page 8 of 10

 Open the catalog to page 8
GSC53N-9

HTCaltek POWER/ENERGY MEASUREMENTS REFERENCE STANDARDS: Features of voltage supplied by public utilities: EN50160 Active energy static counters for AC current : EN61036 (Class 2) Reactive energy static counters for AC current : IEC1268 (Class 3) NOISE MEASUREMENTS REFERENCE STANDARDS: Sound measurements (with HT55probe): EN60651:1994/A1 type 1 ;EN60804:1994/A2 type 1 3. GENERAL SPECIFICATIONS SINGLE/THREE PHASE RECORDING: STORED PARAMETERS: -Phase and delta voltages -Phase currents, neutral current -Phase and total three phase Active, Reactive, Apparent power -Active energy (Class 2 EN61036),...

 Open the catalog to page 9

Archived catalogs

  1. BT501

    2  Pages

  2. BT521

    2  Pages

  3. COMBI419

    9  Pages

  4. BT511

    5  Pages

  5. BT701

    3  Pages

  6. BT513

    5  Pages

  7. BT512

    5  Pages

  8. M73

    9  Pages

  9. BT514

    5  Pages

  10. COMBI420

    11  Pages

  11. PSM2/2A

    4  Pages

  12. BT502

    2  Pages

  13. Scope Meter

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.