1. Catalogs
  2. BST Caltek Industrial Ltd
  3. CP SERIES - ECONOMIC REGULATED DC POWER SUPPLY

CP SERIES - ECONOMIC REGULATED DC POWER SUPPLY

CP SERIES - ECONOMIC REGULATED DC POWER SUPPLY

CP SERIES - ECONOMIC REGULATED DC POWER SUPPLY

Product catalog summary
Overview: The document outlines the specifications and features of the CP Series Economic Regulated DC Power Supply, highlighting its adjustable voltage capabilities, low noise, and protective features.
Features: The CP Series offers linearly adjustable voltage outputs of 0-30V for the CP30 series and 0-15V for the CP15 series. It includes low noise and ripple (<0.3mVrms), dual LED displays for voltage and current with high resolution, and both analog and digital display options. The power supply features automatic mode switching between constant voltage (CV) and constant current (CC), overload protection, and auto current cut-off protection. It is housed in a rugged metal cabinet with switchable 110V/220V AC power input and offers both active fan and passive heatsink cooling options.
General Specifications: The document provides a detailed table of models, indicating their voltage output, maximum current output, display types, and cooling modes. Models are available with different current outputs (2A, 3A, 5A) and display resolutions (3 or 4 digits).
Operational Conditions: The power supply operates under non-condensing conditions at altitudes below 2000m and pollution degree II. It supports input voltages of 110V/220V AC ±10% at 50Hz/60Hz. Fuse protection varies by model, with power consumption ranging from 120W to 300W depending on the output model. Operating temperature is 0-40°C with a relative humidity of ≤85% RH.
Technical Specifications: In constant voltage mode, the line effect is 1×10-4 +3mV, and the loading effect is 1×10-4 +2mV. In constant current mode, the line effect is 2×10-4 +3mA, and the loading effect is 5mA. Display accuracy varies by digit count, with 4-digit displays offering higher precision.
Mechanical Specifications: The power supply's weight ranges from 2.4kg to 2.5kg, and dimensions vary slightly between models with fan or heatsink cooling.
Accessories: Each unit comes with a power cord, instruction manual, and fuse.
Contact Information: Caltek Industrial (H.K.) Ltd. provides contact details for further inquiries.
See more

Catalog excerpts

CP SERIES - ECONOMIC REGULATED DC POWER SUPPLY-1

CP Series Economic Regulated DC Power Supply No Noise Heatsink Cooling 0-30V Voltage Linearly Adjustment (CP30 series) 0-15V Voltage Linearly Adjustment (CP15 series) Low Noise And Ripple Less Than 0.3mVrms 2 Sets of LED Voltage and Current Display with max 10mV/1mA resolution Analog Voltage and Current Display (AF, AH series) Voltage, Current Pre-set Feature CV/CC Mode Automatic Change Overload protection Auto Current Cut Off Protection Rugged Metal Cabinet Active / No Noise Passive Cooling 110V/220V AC power input switchable Due to our policy of continual product development, we reserve the right to amend the specifications of all mentioned products without prior notice.

 Open the catalog to page 1
CP SERIES - ECONOMIC REGULATED DC POWER SUPPLY-2

General Specification Model Number Linearly Voltage output 0~ 30V Cooling Mode Analogue Display Heat Sink Maximum Current Output Due to our policy of continual product development, we reserve the right to amend the specifications of all mentioned products without prior notice.

 Open the catalog to page 2
CP SERIES - ECONOMIC REGULATED DC POWER SUPPLY-3

Model Number Linearly Voltage output 0~ 30V Cooling Mode Analogue Display Heat Sink Maximum Current Output Due to our policy of continual product development, we reserve the right to amend the specifications of all mentioned products without prior notice.

 Open the catalog to page 3
CP SERIES - ECONOMIC REGULATED DC POWER SUPPLY-4

Operation Condition Environmental Condition: Operating altitude <2000m, pollution degree II Input Voltage Fuse Protection: (Fast Blow Type) Power Consumption 120W2A output model 180W3A output model 300W5A output model Temperature040℃ Relative Humidity* ≦85%RH Temperature-10℃80℃ Relative Humidity* ≦85%RH Operating Condition Storage Condition *Non-condensing Due to our policy of continual product development, we reserve the right to amend the specifications of all mentioned products without prior notice.

 Open the catalog to page 4
CP SERIES - ECONOMIC REGULATED DC POWER SUPPLY-5

Technical Specification Constant Voltage Mode (CV) Line Effect Loading Effect: Temperature Coefficient” Constant Current Mode (CC) 2×10-4 +3mA Line Effect: Loading Effect: Temperature Coefficient: Display Accuracy 4 Digits Display ≤ ±(0.1%+5d) Digital Display: 3 Digits Display ≤ ±(0.4%+3d) ≤ ±3% of full range Analog Display: Resolution 4 Digits Voltage Display Resolution: 10mV 4 Digits Current Display Resolution: 1mA 3 Digits Voltage Display Resolution: 100mV 3 Digits Current Display Resolution: 10mA Resume Time Resume Time: Mechanical Specification Weight(kg): Dimension(mm): 2.4kg (Heat Sink)...

 Open the catalog to page 5
CP SERIES - ECONOMIC REGULATED DC POWER SUPPLY-6

Power cord Instruction manual Fuse Flat G, 2/F., Block 4, Golden Dragon Industrial Centre, Nos. 182-190 Tai Lin Pai Road, Kwai Chung, N.T., Hong Kong E-MAIL: [email protected] Due to our policy of continual product development, we reserve the right to amend the specifications of all mentioned products without prior notice.

 Open the catalog to page 6

Archived catalogs

  1. BT501

    2  Pages

  2. BT521

    2  Pages

  3. COMBI419

    9  Pages

  4. BT511

    5  Pages

  5. BT701

    3  Pages

  6. BT513

    5  Pages

  7. BT512

    5  Pages

  8. M73

    9  Pages

  9. BT514

    5  Pages

  10. COMBI420

    11  Pages

  11. PSM2/2A

    4  Pages

  12. GSC53N

    10  Pages

  13. BT502

    2  Pages

  14. Scope Meter

    4  Pages

*Prices are pre-tax. They exclude delivery charges and customs duties and do not include additional charges for installation or activation options. Prices are indicative only and may vary by country, with changes to the cost of raw materials and exchange rates.